文献速递神经外周血管CTDSA

知识增强深度学习在CT血管造影中分割与检测脑动脉瘤:一项多中心研究

Knowledge-Augmented Deep Learning for Segmenting and Detecting Cerebral Aneurysms With CT Angiography: A Multicenter Study.
PubMed 文献 · Radiology · 2024-01-01

该多中心研究基于8家医院2018年2月至2021年10月连续入组的6060例患者CTA图像构建知识增强深度学习模型,用于脑动脉瘤分割与检测,并在118例以DSA为参考标准的外部测试集中验证。模型分割DSC为0.87,检测敏感度85.7%,与放射科报告诊断性能无显著差异(AUC 0.93 vs 0.91,P=0.67)。

要点

  • 模型在外部DSA测试集中检测动脉瘤敏感度为85.7%,AUC 0.93,与放射科报告AUC 0.91无显著差异。
  • 模型分割动脉瘤的Dice相似系数为0.87。
  • 单次扫描从重建到检测的处理时间为1.76分钟±0.32。

核心结论

  • 所提出的深度学习模型可在CTA上准确分割和检测脑动脉瘤,与放射科报告相比诊断性能无显著差异证据。

研究设计与样本

  • 多中心回顾性研究,从8家医院连续收集2018年2月至2021年10月疑似未破裂脑动脉瘤的头部或头颈部CTA图像6060例用于模型开发(训练集4342例、验证集1086例、内部测试集632例)。

关键影像表现/征象

  • 模型在内部测试集中动脉瘤分割的DSC为0.87。
  • 外部测试集以DSA为参考标准,按血管分析模型检测动脉瘤敏感度为85.7%(108/126,95%CI:78.1,90.1)。
  • 模型与放射科报告AUC分别为0.93(95%CI:0.90,0.95)和0.91(95%CI:0.87,0.94),P=0.67。
  • 模型单次扫描从重建到检测的处理时间为1.76分钟±0.32。

诊断标准与关键数值

  • 动脉瘤分割性能以Dice相似系数(DSC)评估,内部测试集DSC为0.87。
  • 动脉瘤检测性能以敏感度和AUC评估,外部DSA测试集按血管分析敏感度85.7%(108/126,95%CI:78.1,90.1)。
  • 模型与放射科报告AUC比较采用DeLong检验,AUC 0.93(95%CI:0.90,0.95)vs 0.91(95%CI:0.87,0.94),P=0.67。

临床应用与阅片要点

  • 模型可在CTA上自动分割和检测脑动脉瘤,单次扫描处理时间1.76分钟±0.32。
  • 模型检测性能与放射科报告相比无显著差异证据(AUC 0.93 vs 0.91,P=0.67)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Deep learning (DL) could improve the labor-intensive, challenging processes of diagnosing cerebral aneurysms but requires large multicenter data sets. Purpose To construct a DL model using a multicenter data set for accurate cerebral aneurysm segmentation and detection on CT angiography (CTA) images and to compare its performance with radiology reports. Materials and Methods Consecutive head or head and neck CTA images of suspected unruptured cerebral aneurysms were gathered retrospectively from eight hospitals between February 2018 and October 2021 for model development. An external test set with reference standard digital subtraction angiography (DSA) scans was obtained retrospectively from one of the eight hospitals between February 2022 and February 2023. Radiologists (reference standard) assessed aneurysm segmentation, while model performance was evaluated using the Dice similarity coefficient (DSC). The model's aneurysm detection performance was assessed by sensitivity and comparing areas under the receiver operating characteristic curves (AUCs) between the model and radiology reports in the DSA data set with use of the DeLong test. Results Images from 6060 patients (mean age, 56 years ± 12 [SD]; 3375 [55.7%] female) were included for model development (training: 4342; validation: 1086; and internal test set: 632). Another 118 patients (mean age, 59 years ± 14; 79 [66.9%] female) were included in an external test set to evaluate performance based on DSA. The model achieved a DSC of 0.87 for aneurysm segmentation performance in the internal test set. Using DSA, the model achieved 85.7% (108 of 126 aneurysms [95% CI: 78.1, 90.1]) sensitivity in detecting aneurysms on per-vessel analysis, with no evidence of a difference versus radiology reports (AUC, 0.93 [95% CI: 0.90, 0.95] vs 0.91 [95% CI: 0.87, 0.94]; P = .67). Model processing time from reconstruction to detection was 1.76 minutes ± 0.32 per scan. Conclusion The proposed DL model could accurately segment and detect cerebral aneurysms at CTA with no evidence of a significant difference in diagnostic performance compared with radiology reports. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Payabvash in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Wei J, Song X, Wei X, et al. Knowledge-Augmented Deep Learning for Segmenting and Detecting Cerebral Aneurysms With CT Angiography: A Multicenter Study. Radiology. 2024. PMID: 39162636. doi:10.1148/radiol.233197

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。