文献速递神经CT

临床因素、CT征象及影像组学联合用于鉴别急性缺血性卒中机械取栓术后高密度区

Combinations of Clinical Factors, CT Signs, and Radiomics for Differentiating High-Density Areas after Mechanical Thrombectomy in Patients with Acute Ischemic Stroke.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-01-08

回顾性纳入中心I的156例与中心II的63例大血管闭塞急性缺血性卒中机械取栓术后患者,构建临床因素与CT征象模型、影像组学模型及联合模型,联合模型诊断效能最高,三个数据集AUC分别为0.895、0.882、0.820。

要点

  • 联合模型鉴别高密度区为出血转化或非出血转化效能最高,外部验证AUC为0.820。
  • 临床血糖与CT最大横截面积是高密度区出血转化的独立相关因素(P < .05)。
  • 影像组学特征可作为影像生物标志物辅助判断取栓术后高密度区性质。

核心结论

  • 基于影像组学的联合模型诊断效能最佳,影像组学特征可作为影像生物标志物辅助临床判断机械取栓术后高密度区的性质。

研究设计与样本

  • 回顾性研究,中心I自2015年12月至2023年6月纳入156例大血管闭塞急性缺血性卒中患者,按7:3随机分为训练集109例与内部验证集47例,中心II的63例作为外部验证集。

关键影像表现/征象

  • 高密度区根据诊断标准分为出血转化组与非出血转化组。
  • CT最大横截面积与高密度区出血转化与否相关(多因素logistic回归P < .05)。

诊断标准与关键数值

  • 联合模型在训练集、内部验证集、外部验证集的AUC分别为0.895、0.882、0.820。
  • 影像组学模型在三个数据集的AUC分别为0.887、0.898、0.798。
  • 临床因素与CT征象模型在三个数据集的AUC分别为0.831、0.744、0.684。

临床应用与阅片要点

  • 联合模型诊断效能最高,AUC在三个数据集均高于影像组学模型与临床因素及CT征象模型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Clinically, hemorrhagic transformation (HT) after mechanical thrombectomy (MT) is a common complication. This study aimed to investigate the value of clinical factors, CT signs, and radiomics in the differential diagnosis of high-density areas (HDAs) in the brain after MT in patients with acute ischemic stroke with large-vessel occlusion (AIS-LVO).

MATERIALS AND METHODS: A total of 156 eligible patients with AIS-LVO in Center I from December 2015 to June 2023 were retrospectively enrolled and randomly divided into training (n = 109) and internal validation (n = 47) sets at a ratio of 7:3. The data of 63 patients in Center II were collected as an external validation set. According to the diagnostic criteria, the patients in the 3 data sets were divided into an HT group and a non-HT group. The clinical and imaging data from Centers I and II were used to construct a clinical factor and CT-sign model, a radiomics model, and a combined model by logistic regression. Receiver operating characteristic analysis was used to evaluate the diagnostic efficacy of each model in the 3 data sets.

RESULTS: Clinical blood glucose and the maximum cross-sectional area on CT were associated with the HT or non-HT of the HDA according to multivariate logistic regression analyses (P < .05). Among the 3 models, the combined model had the highest diagnostic efficiency, with area under the curve values of 0.895, 0.882, and 0.820 in the 3 data sets, which were significantly greater than the area under the curve values of the radiomics model (0.887, 0.898, 0.798) and clinical factor and CT-sign model (0.831, 0.744, 0.684).

CONCLUSIONS: The combined model based on radiomics had the best performance, indicating that radiomics features can be used as imaging biomarkers to aid in the clinical judgment of the nature of HDA after MT.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Zhai D, Wu Y, Cui M, et al. Combinations of Clinical Factors, CT Signs, and Radiomics for Differentiating High-Density Areas after Mechanical Thrombectomy in Patients with Acute Ischemic Stroke. AJNR Am J Neuroradiol. 2025. PMID: 39122469. doi:10.3174/ajnr.A8434

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。