文献速递神经外周血管CT

优化急性卒中评估:评估联合脑CT灌注与头颈CT血管成像的「真正」一站式扫描方案在512层探测器CT扫描仪上的临床应用价值

Enhancing acute stroke assessment: evaluating the clinical utility of the "Real" one-stop-shop scan protocol combining brain computed tomography perfusion and head-and-neck computed tomography angiography using a 512-slice detector computed tomography scanner.
PubMed 文献 · Clin Radiol · 2024-08-06

前瞻性研究将100例疑似急性缺血性卒中患者随机分为两组,实验组采用一站式方案(联合脑CT灌注与头颈CTA,CTA触发时间由低剂量试验性团注注射确定),对照组采用传统方案(分别行脑CT灌注和头颈CTA)。实验组总碘对比剂剂量(80 vs 100 ml,P<0.001)、扫描时间(3.23 vs 2.32 min,P<0.001)和辐射剂量(5129.00 vs 4681.35 mGy-cm,P<0.001)均显著低于对照组,后处理时间及头颈CTA、CTP图像质量无统计学显著差异。作者认为该一站式方案能有效检测病灶并清晰显示头颈部血管狭窄位置和程度,值得考虑作为急性缺血性卒中患者的首选检查。

要点

  • 一站式方案总碘对比剂剂量80 ml,低于传统方案的100 ml(P<0.001)。
  • 一站式方案扫描时间2.32 min,短于传统方案的3.23 min(P<0.001)。
  • 一站式方案辐射剂量4681.35 mGy-cm,低于传统方案的5129.00 mGy-cm(P<0.001)。

核心结论

  • 一站式方案能有效检测病灶并清晰显示头颈部血管狭窄的位置和程度,扫描时间、对比剂剂量和辐射剂量均低于传统方案,作者认为值得考虑作为急性缺血性卒中患者的首选检查。

研究设计与样本

  • 前瞻性研究,纳入100例疑似急性缺血性卒中患者,随机分为对照组(n=50,传统方案:脑CTP与头颈CTA分开检查)和实验组(n=50,一站式方案:联合脑CTP与头颈CTA,CTA触发时间由低剂量试验性团注注射确定),使用512层探测器CT扫描仪,比较两组的检查时间、对比剂剂量、辐射剂量、后处理时间和图像质量。

诊断标准与关键数值

  • 实验组总碘对比剂剂量80 ml vs 对照组100 ml(P<0.001)。
  • 实验组扫描时间2.32(2.17,2.45)min vs 对照组3.23(3.13,3.35)min(P<0.001)。
  • 实验组辐射剂量4681.35(4555.12,4822.95)mGy-cm vs 对照组5129.00(5173,5232)mGy-cm(P<0.001)。
  • 两组后处理时间、头颈CTA和CTP图像质量无统计学显著差异。

临床应用与阅片要点

  • 一站式方案可清晰显示头颈部血管狭窄的位置和程度,并有效检测病灶。
  • 作者认为该方案值得考虑作为急性缺血性卒中患者的首选检查。
  • CTA触发时间由低剂量试验性团注注射确定。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the efficiency and diagnostic value of the "real" one-stop-shop protocol integrating the computed tomography angiography (CTA) sequence of the head and neck into the computed tomography perfusion (CTP) acquisition using a 512-slice detector CT scanner in patients who suffered from acute ischemic stroke.

MATERIALS AND METHODS: This prospective study included 100 patients suspected of acute ischemic stroke. The patients were randomly divided into two groups: the control group (n=50) who underwent the traditional protocol (brain CTP and head-and-neck CTA examination separately) and the experimental group (n=50) who underwent a one-stop-shop protocol (combined brain CT perfusion and head-and-neck CTA, the CTA triggering time determined by a low-dose test bolus injection). The examination time, contrast-agent dosage, radiation dose, postprocessing time, and image quality were compared between the two groups.

RESULTS: Compared to the control group, the experimental group had a significantly lower total iodine contrast-agent dosage (80 vs. 100 ml, P<0.001) and shorter scan time (3.23 [3.13, 3.35] vs. 2.32 [2.17, 2.45] min, P<0.001). Additionally, the radiation dose exposure was lower in the experimental group than in the control group (5129.00 [5173, 5232] vs. 4681.35 [4555.12, 4822.95] mGy-cm, P<0.001). No statistically significant differences were observed between the two groups in terms of postprocessing time, head-and-neck CTA, and CTP imaging quality.

CONCLUSION: The one-stop-shop protocol enables effective detection of lesions, providing clear visualization of the location and degree of stenosis in the head-and-neck vessels. It achieves this with lower costs in scan time, contrast-agent dosage, and radiation dose compared to the traditional protocol and is thus worth considering as the first examination for patients who suffer from acute ischemic stroke.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Jiang Y, Jiang J, Li J, et al. Enhancing acute stroke assessment: evaluating the clinical utility of the "Real" one-stop-shop scan protocol combining brain computed tomography perfusion and head-and-neck computed tomography angiography using a 512-slice detector computed tomography scanner. Clin Radiol. 2024. PMID: 39198108. doi:10.1016/j.crad.2024.07.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。