分数肿瘤负荷图提高脑MR灌注阅片信心
多阅片者研究纳入30例星形细胞瘤和胶质母细胞瘤患者,比较常规MRI灌注(含区域脑血容量图)加或不加分数肿瘤负荷图的诊断表现;加用后诊断准确率无显著差异(Z=0.76,p=0.450),但阅片者信心显著提高(Z=454,p<0.01)。
要点
- 加用分数肿瘤负荷图后诊断信心显著提高(Z=454,p<0.01)。
- 加用后平均敏感度79.5%、平均特异度54.2%,与不加用无显著差异。
- 分数肿瘤负荷图阅片中位耗时19秒,后处理中位耗时313秒。
核心结论
- 加用分数肿瘤负荷图对术后高级别星形细胞瘤和胶质母细胞瘤的影像随访不增加额外价值,但可提高阅片者诊断信心。
研究设计与样本
- 多阅片者研究,纳入30例星形细胞瘤和胶质母细胞瘤患者,由5名具有不同经验水平的放射学背景阅片者在一个阅片时段内评估。
- 先提供常规MRI序列数据集(包括灌注MRI的区域脑血容量图),再扩展加入相应的分数肿瘤负荷图。
- 以临床和影像随访和/或组织病理学数据作为金标准确定最终诊断。
诊断标准与关键数值
- 不使用分数肿瘤负荷图时平均敏感度83.3%、平均特异度55.1%。
- 加用分数肿瘤负荷图后平均敏感度79.5%、平均特异度54.2%。
- 加用与不加用分数肿瘤负荷图的诊断准确率无显著差异(Z=0.76,p=0.450)。
- 加用分数肿瘤负荷图后阅片者信心显著提高(Z=454,p<0.01)。
- 分数肿瘤负荷图后处理中位时间313秒,分数肿瘤负荷图评估中位时间19秒。
临床应用与阅片要点
- 原文结论未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Various methods exist to perform and post-process perfusion weighted MR imaging in the post-treatment imaging of glioma patients to differentiate tumor progression from tumor-related abnormalities. One of these post-processing methods produces 'fractional tumor burden' maps. This multi-reader study investigated the clinical feasibility of fractional tumor burden maps on real world data from radiological follow-up of high-grade astrocytoma patients.
METHODS: Five readers with background in radiology and varying levels of experience were tasked with assessing 30 astrocytoma and glioblastoma patients during one reader session. First, they were provided with a dataset of conventional MRI sequences, including perfusion MRI with regional cerebral blood volume maps. Then the dataset was expanded with a corresponding fractional tumor burden maps. Diagnostic accuracy, duration of post-processing, duration of the assessment of the fractional tumor burden maps, the diagnostic confidence reported by the readers and their diagnoses were recorded. Final diagnosis was determined by clinical and radiological follow-up and/or histopathological data used as gold standard.
RESULTS: A mean sensitivity of 83.3 % and mean specificity of 55.1 % was obtained without the use of fractional tumor burden maps, whereas their additional of fractional tumor burden maps resulted in a mean sensitivity and specificity of 79.5 % and 54.2 %, respectively. Diagnostic accuracies with and without fractional tumor burden maps were not significantly different (Z = 0.76, p = 0.450). The median time spent post-processing was 313 s, while the median duration of the assessment of the FTB maps was 19 s. Interestingly, reader confidence increased significantly after adding the fractional tumor burden-maps to the assessment (Z = 454, p < 0.01).
CONCLUSIONS: While the use of fractional tumor burden maps does not carry additional value in the radiological follow-up of post-operative high-grade astrocytoma and glioblastoma patients, it does give readers more confidence in their diagnosis.
引用
- Herings SDA, van der Wijk MW, von Beckerath V, et al. Fractional tumor burden maps increase the confidence of reading brain MR perfusion. Eur J Radiol. 2024. PMID: 39084028. doi:10.1016/j.ejrad.2024.111644
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。