文献速递外周血管心血管CT

舌下含服硝酸甘油后CT血管造影对Adamkiewicz动脉的评估

Computed tomography angiography assessment of Adamkiewicz artery with sublingual nitroglycerin administration.
PubMed 文献 · Neuroradiology · 2024-08-05

本研究从主动脉瘤手术前后行增强CT检查的33例病例中,比较术前冠状动脉评估时给予硝酸甘油与术后未给药时Adamkiewicz动脉的显示情况。结果显示给药后对比噪声比、CT值及动脉直径显著增加,Adamkiewicz动脉评分显著改善,图像噪声无显著差异,提示硝酸甘油有助于改善Adamkiewicz动脉的可视化。

要点

  • 舌下含服硝酸甘油可显著提高Adamkiewicz动脉的对比噪声比和CT值,并使其直径扩张。
  • 硝酸甘油给药后Adamkiewicz动脉的四级评分显著改善,图像噪声无显著差异。
  • 主动脉手术前识别Adamkiewicz动脉对预防脊髓缺血相关术后并发症具有重要意义。

核心结论

  • 硝酸甘油有助于改善Adamkiewicz动脉的可视化。

研究设计与样本

  • 研究提取33例主动脉瘤手术前后行增强CT检查的病例;术前CT为冠状动脉评估给予硝酸甘油,术后CT未给予硝酸甘油;由两名独立评估者测量主动脉对比噪声比、CT值、图像噪声及Adamkiewicz动脉和前脊髓动脉直径,并将Adamkiewicz动脉显示分为四级评估。

关键影像表现/征象

  • 给予硝酸甘油的病例中,对比噪声比和CT值均显著更高(分别为P < 0.001、P < 0.001)。
  • 给予硝酸甘油的病例中,Adamkiewicz动脉和前脊髓动脉直径均扩张(分别为P = 0.005、P = 0.001)。
  • Adamkiewicz动脉评分也显著改善(P < 0.001)。
  • 图像噪声无显著差异。

诊断标准与关键数值

  • Adamkiewicz动脉的显示情况采用四级评分法进行评估,原文未报告各级的具体定义。
  • 原文未报告敏感度、特异度、AUC或诊断阈值。

临床应用与阅片要点

  • 本研究提示舌下含服硝酸甘油可能有助于改善Adamkiewicz动脉的CT血管造影可视化。
  • 原文未据此给出具体的临床操作推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Identification of the Adamkiewicz artery before aortic surgery is important for preventing postoperative complications due to spinal cord ischemia. The Adamkiewicz artery is difficult to identify due to its small diameter. Nitroglycerin has a vasodilatory effect and is used clinically to improve visualization of blood vessels on coronary computed tomography (CT) angiography. We investigated whether the vasodilatory effect of nitroglycerin could improve the ability to visualize the Adamkiewicz artery.

METHODS: We extracted 33 cases wherein contrast-enhanced CT images were taken before and after aortic aneurysm surgery. Nitroglycerin was administered for coronary artery evaluation on the preoperative CT. However, no nitroglycerin was administered before the postoperative CT. Aortic contrast-to-noise ratio, CT value, image noise, and diameter of the Adamkiewicz artery and anterior spinal artery were measured. The depiction of the Adamkiewicz artery was graded into four grades and evaluated. These measurements were performed by two independent reviewers.

RESULTS: In nitroglycerin-administered cases, the contrast-to-noise ratio and CT values were significantly higher (P < 0.001, P < 0.001, respectively); the Adamkiewicz artery and anterior spinal artery diameters were dilated (P = 0.005, P = 0.001, respectively). The Adamkiewicz artery score also improved significantly (P < 0.001). No significant difference was found in image noise.

CONCLUSION: Nitroglycerin contributed to improving the Adamkiewicz artery's visualization.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Higuchi A, Kubota Y, Yokota H, et al. Computed tomography angiography assessment of Adamkiewicz artery with sublingual nitroglycerin administration. Neuroradiology. 2024. PMID: 39102086. doi:10.1007/s00234-024-03433-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。