文献速递骨肌神经技术与安全CTMR

影像组学模型鉴别良恶性椎体压缩骨折的诊断价值:系统综述与Meta分析

Differential diagnostic value of radiomics models in benign versus malignant vertebral compression fractures: A systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2024-07-14

该系统综述与Meta分析纳入16篇文献共1519个经病理诊断肿瘤浸润的椎体,评估影像组学模型鉴别良恶性椎体压缩骨折的诊断效能。表现最佳模型的合并敏感度0.92(95%CI 0.87-0.96)、特异度0.93(95%CI 0.88-0.96)、AUC 0.97(95%CI 0.96-0.99);放射科医师合并敏感度0.90(95%CI 0.75-0.97)、特异度0.92(95%CI 0.67-0.98)、AUC 0.96(95%CI 0.94-0.97)。亚组分析提示部分异质性可能由成像方式、分割、深度学习和交叉验证的差异解释,已发表模型仍存在较大异质性,需更多大规模临床试验验证其泛化性。

要点

  • 表现最佳影像组学模型鉴别良恶性椎体压缩骨折的合并敏感度0.92、特异度0.93、AUC 0.97。
  • 放射科医师合并敏感度0.90、特异度0.92、AUC 0.96,与模型诊断效能接近。
  • 已发表影像组学模型间异质性较大,需更多大规模临床试验验证泛化性。

核心结论

  • 影像组学模型在复杂临床情境下正确鉴别椎体压缩骨折方面显示出显著诊断潜力,但已发表模型仍存在较大异质性,需更多大规模临床试验验证其泛化性。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Embase、Web of Science和Cochrane Library截至2023年9月23日发表的文献,采用影像组学质量评分(RQS)和诊断准确性研究质量评估-2(QUADAS-2)评估方法学质量与偏倚风险,纳入提供混淆矩阵结果的研究进行随机效应Meta分析,共纳入16篇文献、涉及1519个经病理诊断肿瘤浸润的椎体。

诊断标准与关键数值

  • 表现最佳模型的合并敏感度0.92(95%CI 0.87-0.96)、特异度0.93(95%CI 0.88-0.96)、AUC 0.97(95%CI 0.96-0.99);放射科医师合并敏感度0.90(95%CI 0.75-0.97)、特异度0.92(95%CI 0.67-0.98)、AUC 0.96(95%CI 0.94-0.97)。

临床应用与阅片要点

  • 作者认为影像组学模型在正确鉴别椎体压缩骨折方面具有显著诊断潜力,但已发表模型仍存在较大异质性,需更多大规模临床试验验证其泛化性。

局限性

  • 已发表的影像组学模型仍存在较大异质性。
  • 需更多大规模临床试验验证其泛化性。
  • 亚组分析和敏感性检验提示部分异质性可能由成像方式、分割、深度学习和交叉验证的差异解释。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Early diagnosis of benign and malignant vertebral compression fractures by analyzing imaging data is crucial to guide treatment and assess prognosis, and the development of radiomics made it an alternative option to biopsy examination. This systematic review and meta-analysis was conducted with the purpose of quantifying the diagnostic efficacy of radiomics models in distinguishing between benign and malignant vertebral compression fractures.

METHODS: Searching on PubMed, Embase, Web of Science and Cochrane Library was conducted to identify eligible studies published before September 23, 2023. After evaluating for methodological quality and risk of bias using the Radiomics Quality Score (RQS) and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2), we selected studies providing confusion matrix results to be included in random-effects meta-analysis.

RESULTS: A total of sixteen articles, involving 1,519 vertebrae with pathological-diagnosed tumor infiltration, were included in our meta-analysis. The combined sensitivity and specificity of the top-performing models were 0.92 (95 % CI: 0.87-0.96) and 0.93 (95 % CI: 0.88-0.96), respectively. Their AUC was 0.97 (95 % CI: 0.96-0.99). By contrast, radiologists' combined sensitivity was 0.90 (95 %CI: 0.75-0.97) and specificity was 0.92 (95 %CI: 0.67-0.98). The AUC was 0.96 (95 %CI: 0.94-0.97). Subsequent subgroup analysis and sensitivity test suggested that part of the heterogeneity might be explained by differences in imaging modality, segmentation, deep learning and cross-validation.

CONCLUSION: We found remarkable diagnosis potential in correctly distinguishing vertebral compression fractures in complex clinical contexts. However, the published radiomics models still have a great heterogeneity, and more large-scale clinical trials are essential to validate their generalizability.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zheng J, Liu W, Chen J, et al. Differential diagnostic value of radiomics models in benign versus malignant vertebral compression fractures: A systematic review and meta-analysis. Eur J Radiol. 2024. PMID: 39018646. doi:10.1016/j.ejrad.2024.111621

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。