利用深度学习从降采样光学分辨率光声显微图像重建松质骨
本研究提出光声密集注意力U-Net(PADA U-Net)模型,用于从欠采样图像重建全扫描图像,以突破光学分辨率光声显微(OR-PAM)成像速度与空间分辨率之间的权衡。在分辨率测试靶和牛松质骨样本上验证,降采样比为[4,1]时,PADA U-Net较双线性插值的峰值信噪比和结构相似性指数分别提高2.325 dB和0.117。结果表明该模型能重建不同稀疏程度的OR-PAM图像,作者认为可进一步促进骨疾病的早期诊断和治疗。
要点
- PADA U-Net可从欠采样OR-PAM图像重建全扫描图像,突破成像速度与分辨率的权衡。
- 降采样比[4,1]时,PADA U-Net较双线性插值PSNR提高2.325 dB、SSIM提高0.117。
- 模型在分辨率测试靶和牛松质骨样本上验证,能重建不同稀疏程度的图像。
核心结论
- PADA U-Net模型能良好重建不同稀疏程度的OR-PAM图像,作者认为该方法可进一步促进利用OR-PAM进行骨疾病的早期诊断和治疗。
研究设计与样本
- 研究提出光声密集注意力U-Net(PADA U-Net)模型,用于从欠采样图像重建全扫描图像,在分辨率测试靶和牛松质骨样本上验证。
诊断标准与关键数值
- 降采样比为[4,1]时,PADA U-Net较双线性插值,在牛松质骨测试集上平均峰值信噪比提高2.325 dB,结构相似性指数提高0.117。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Bone diseases deteriorate the microstructure of bone tissue. Optical-resolution photoacoustic microscopy (OR-PAM) enables high spatial resolution of imaging bone tissues. However, the spatiotemporal trade-off limits the application of OR-PAM. The purpose of this study was to improve the quality of OR-PAM images without sacrificing temporal resolution.
METHODS: In this study, we proposed the Photoacoustic Dense Attention U-Net (PADA U-Net) model, which was used for reconstructing full-scanning images from under-sampled images. Thereby, this approach breaks the trade-off between imaging speed and spatial resolution.
RESULTS: The proposed method was validated on resolution test targets and bovine cancellous bone samples to demonstrate the capability of PADA U-Net in recovering full-scanning images from under-sampled OR-PAM images. With a down-sampling ratio of [4, 1], compared to bilinear interpolation, the Peak Signal-to-Noise Ratio and Structural Similarity Index Measure values (averaged over the test set of bovine cancellous bone) of the PADA U-Net were improved by 2.325 dB and 0.117, respectively.
CONCLUSION: The results demonstrate that the PADA U-Net model reconstructed the OR-PAM images well with different levels of sparsity. Our proposed method can further facilitate early diagnosis and treatment of bone diseases using OR-PAM.
引用
- Wang J, Li B, Zhou T, et al. Reconstructing Cancellous Bone From Down-Sampled Optical-Resolution Photoacoustic Microscopy Images With Deep Learning. Ultrasound Med Biol. 2024. PMID: 38972792. doi:10.1016/j.ultrasmedbio.2024.05.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。