优化单能图像以减少双层光谱CT下颈椎下段条带伪影:一项回顾性研究
该回顾性研究纳入63例颈部光谱CT检查患者,比较常规混合能量图像与40–200 KeV单能图像,测量椎间盘SD、SNR、C6-7与C3-4伪影区CT值差及C6-7椎管CNR。结果显示120 KeV图像椎间盘SD最低、SNR最高、CT值差最低、主观评分最高,提示单能120 KeV图像可能有助于减少颈椎下段条带伪影。
要点
- 120 KeV单能图像椎间盘SD最低、SNR最高(6.20 ± 5.26),伪影区CT值差最低(10.63 ± 8.58)。
- 40 KeV图像SNR最低(2.07 ± 2.74),伪影区CT值差最高(108.38)。
- 120 KeV图像主观图像质量评分最高,40 KeV最低。
核心结论
- 研究提示单能120 KeV图像可能具有椎间盘SD低、SNR升高、CNR较高及图像质量改善等优势。
研究设计与样本
- 回顾性研究,纳入2022年3月至2023年1月间63例接受颈部光谱CT检查的患者,获取常规混合能量图像及40–200 KeV光谱成像数据。
关键影像表现/征象
- 椎间盘SD在40 KeV单能图像最高、120 KeV图像最低(P<0.05)。
- SNR在40 KeV图像最低(2.07 ± 2.74)、120 KeV图像最高(6.20 ± 5.26)(P<0.05)。
- C6-7与C3-4伪影区CT值差在40 KeV图像最高、120 KeV图像最低(108.38 vs. 10.63 ± 8.58)。
- 伪影区主观图像质量评分在40 KeV图像最低、120 KeV图像最高。
临床应用与阅片要点
- 作者认为单能120 KeV图像可能有助于降低颈椎下段条带伪影、提升图像质量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the application value of dual-layer detector computed tomography (CT) single-energy spectral images for reducing artefacts in the lower cervical spine.
MATERIALS AND METHODS: Sixty-three patients who underwent neck examination using spectral CT between March 2022 and January 2023 were selected as the participants. Conventional mixed-energy images and spectral imaging data at 40-200 KeV were obtained from the spectral CT scans. The standard deviation (SD), signal-to-noise ratio (SNR), |CTdifference| (the difference in CT value between the C6-7 and C3-4 artefact regions), and contrast-to-noise ratio (CNR) of the C6-7 spinal canal were measured. The image quality of the artefact region in the conventional and single images were compared.
RESULTS: The SDintervertebral disc value was highest in the single-level 40 KeV images and lowest in the 120 KeV images (P<0.05). The SNR was lowest in the 40 KeV images (2.07 ± 2.74) and highest in the 120 KeV images (6.20 ± 5.26) (P<0.05). The CTdifference was highest in the 40 KeV images and lowest in the 120 KeV images (108.38 vs. 10.63 ± 8.58). The subjective image quality scores were lowest in the 40 KeV images and highest in the 120 KeV images.
CONCLUSION: Our findings suggest that single-energy 120 KeV images may offer benefits such as low SDintervertebral disc, elevated SNR, higher CNR, and improved image quality.
引用
- Zhang L, Zhao B, Wang S, et al. Optimisation of monoenergetic images to reduce banding artifacts in the lower cervical spine using dual-layer spectral computed tomography: a retrospective study. Clin Radiol. 2024. PMID: 39069447. doi:10.1016/j.crad.2024.07.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。