人工智能算法在儿童患者四肢骨折检测中的诊断效能
本回顾性研究纳入600例年龄小于17岁儿童的四肢X线片,以随访X线片和/或二级影像为参考标准,评估一种曾在成人和儿童患者中训练的人工智能算法检测急性四肢骨折的诊断效能。按患者分析,敏感度为91.3%(95%CI 87.6-94.3),特异度为76.7%(95%CI 71.5-81.3),准确率为84%(95%CI 82.1-86.0);按摄片分析,敏感度为85%(95%CI 81.9-87.8),特异度为88.5%(95%CI 86.3-90.4),准确率为87.2%(95%CI 85.7-89.6)。结论认为该人工智能算法对儿童四肢骨折检测具有较好的总体诊断效能。
要点
- 按患者分析,AI检测儿童四肢骨折的敏感度为91.3%,特异度为76.7%,准确率为84%。
- 按摄片分析,AI检测儿童四肢骨折的敏感度为85%,特异度为88.5%,准确率为87.2%。
- 按位置分析,AI识别606个边界框,其中正确77.9%、错误18.1%、未重叠4.0%。
核心结论
- 该人工智能算法对儿童患者四肢骨折检测具有较好的总体诊断效能。
研究设计与样本
- 回顾性研究,纳入600例年龄小于17岁儿童的四肢X线片,维持骨折阳性与阴性的平衡,按身体部位分组(肩/锁骨、肘/上臂、手/腕、腿/膝、足/踝)。
- 以随访X线片和/或二级影像作为参考标准。
- 深度学习算法按患者、按摄片和按位置水平解读X线片以检测骨折,并与参考标准比较诊断效能。
诊断标准与关键数值
- 按患者分析,AI检测所有骨折的敏感度为91.3%(95%CI 87.6-94.3),特异度为76.7%(95%CI 71.5-81.3),准确率为84%(95%CI 82.1-86.0)。
- 按摄片分析,AI检测所有骨折的敏感度为85%(95%CI 81.9-87.8),特异度为88.5%(95%CI 86.3-90.4),准确率为87.2%(95%CI 85.7-89.6)。
- 按位置分析,AI识别606个边界框,其中472个(77.9%)正确,110个(18.1%)错误,24个(4.0%)未重叠。
临床应用与阅片要点
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of an Artificial Intelligence (AI) algorithm, previously trained using both adult and pediatric patients, for the detection of acute appendicular fractures in the pediatric population on conventional X-ray radiography (CXR).
MATERIALS AND METHODS: In this retrospective study, anonymized extremities CXRs of pediatric patients (age <17 years), with or without fractures, were included. Six hundred CXRs (maintaining the positive-for-fracture and negative-for-fracture balance) were included, grouping them per body part (shoulder/clavicle, elbow/upper arm, hand/wrist, leg/knee, foot/ankle). Follow-up CXRs and/or second-level imaging were considered as reference standard. A deep learning algorithm interpreted CXRs for fracture detection on a per-patient, per-radiograph, and per-location level, and its diagnostic performance values were compared with the reference standard. AI diagnostic performance was computed by using cross-tables, and 95 % confidence intervals [CIs] were obtained by bootstrapping.
RESULTS: The final cohort included 312 male and 288 female with a mean age of 8.9±4.5 years. Three undred CXRs (50 %) were positive for fractures, according to the reference standard. For all fractures, the AI tool showed a per-patient 91.3% (95%CIs = 87.6-94.3) sensitivity, 76.7% (71.5-81.3) specificity, and 84% (82.1-86.0) accuracy. In the per-radiograph analysis the AI tool showed 85% (81.9-87.8) sensitivity, 88.5% (86.3-90.4) specificity, and 87.2% (85.7-89.6) accuracy. In the per-location analysis, the AI tool identified 606 bounding boxes: 472 (77.9 %) were correct, 110 (18.1 %) incorrect, and 24 (4.0 %) were not-overlapping.
CONCLUSION: The AI algorithm provides good overall diagnostic performance for detecting appendicular fractures in pediatric patients.
引用
- Franco PN, Maino C, Mariani I, et al. Diagnostic performance of an AI algorithm for the detection of appendicular bone fractures in pediatric patients. Eur J Radiol. 2024. PMID: 39053306. doi:10.1016/j.ejrad.2024.111637
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。