T2*软骨成像在早期中轴型脊柱关节炎中的诊断准确性及其与临床特征、骶髂关节炎MRI评分和扩散指标的相关性
这项前瞻性研究纳入83例中轴型脊柱关节炎患者和37例非中轴型脊柱关节炎患者,评估T2*软骨成像在诊断早期中轴型脊柱关节炎和评估疾病活动度中的价值,并探讨软骨损伤与临床特征、骶髂关节炎MRI评分及扩散指标的关系。结果显示中轴型脊柱关节炎患者的T2*值显著高于非中轴型脊柱关节炎患者,T2*值与MRI活动性骶髂关节炎联合诊断的AUC最高,T2*值在不同疾病活动度组间存在显著差异。结论认为T2*值可能是有前景的生物标志物。
要点
- 中轴型脊柱关节炎患者骶髂关节T2*值显著高于非中轴型脊柱关节炎患者。
- T2*值与MRI活动性骶髂关节炎联合诊断中轴型脊柱关节炎的AUC最高。
- T2*值与疾病活动度、急性骶髂关节炎及结构损伤程度相关。
核心结论
- T2*值可能是有前景的生物标志物,用于诊断早期中轴型脊柱关节炎并区分疾病活动度;急性和慢性骶髂关节炎均影响软骨特性。
研究设计与样本
- 前瞻性研究,纳入83例中轴型脊柱关节炎患者和37例非中轴型脊柱关节炎患者;记录临床特征、国际脊柱关节炎评估协会定义的MRI活动性骶髂关节炎及骶髂关节T2*值;采用Mann-Whitney U检验、Kruskal-Wallis检验(FDR校正)、ROC曲线和线性回归进行统计分析。
诊断标准与关键数值
- 中轴型脊柱关节炎患者骶髂关节T2*值为22.86 ± 2.42 ms,非中轴型脊柱关节炎患者为20.36 ± 1.30 ms,组间差异p < 0.001;T2*值与MRI活动性骶髂关节炎联合诊断中轴型脊柱关节炎的AUC最高;T2*值在无活动与极高活动组、中等与极高活动组、高与极高活动组、无活动与高活动组之间差异均显著(pFDR < 0.05);Dk(β = 0.48)和CSDS(β = 0.48)与T2*值独立相关。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine the performance of T2* cartilage mapping in diagnosing and assessing disease activity in early axial spondyloarthritis (axSpA), and to investigate the interaction of cartilage damage with clinical characteristics, sacroiliitis MRI scorings, and diffusion metrics.
MATERIALS AND METHODS: This prospective study included 83 axSpA patients and 37 no-axSpA patients. Clinical characteristics, the Assessment of SpondyloArthritis International Society-defined active sacroiliitis on MRI, and T2* SIJs values were recorded. In axSpA, disease activity was evaluated using the ankylosing spondylitis disease activity score-C-reactive protein; active sacroiliitis was evaluated using Spondyloarthritis Research Consortium of Canada, intravoxel incoherent motion, and diffusion kurtosis imaging; chronic sacroiliitis was assessed using composite structural damage score (CSDS) and structural score fat. Mann-Whitney U-test, Kruskal-Wallis test with false discovery rate (FDR), ROC curve, and linear regression were used for statistical analysis.
RESULTS: AxSpA patients had significantly higher T2*SIJs values than no-axSpA patients. (22.86 ± 2.42 ms vs 20.36 ± 1.30 ms, p < 0.001). The combination of T2*SIJs values and active sacroiliitis on MRI had the highest AUC for identifying axSpA. T2*SIJs values were significantly different between the inactive and very high, moderate and very high, high and very high, as well as inactive and high disease activity groups (all pFDR < 0.05). Dk (β = 0.48) and CSDS (β = 0.48) were independently associated with T2*SIJs values.
CONCLUSION: T2* values may be a promising biomarker for diagnosing and differentiating disease activity in early axSpA. Both acute and chronic sacroiliitis influence cartilage properties.
CLINICAL RELEVANCE STATEMENT: Sacroiliac joint cartilage abnormalities can be quantified with T2* relaxation time and allow better characterization of early axSpA.
KEY POINTS: T2* mapping may have value in evaluating axSpA. The combination of T2* values and active sacroiliitis on MRI enhances diagnostic performance for axSpA. Abnormalities measured with T2* values correlate with disease activity, acute sacroiliitis, and degree of structural damage.
引用
- Huang H, Zhuang F, Liu X, et al. T2* cartilage mapping in early axial spondyloarthritis: diagnostic accuracy and correlation with clinical characteristics, sacroiliitis MRI scorings, and diffusion metrics. Eur Radiol. 2024. PMID: 39048742. doi:10.1007/s00330-024-10975-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。