脊柱深度学习重建T2加权Dixon成像:对采集时间与图像质量的影响
这项前瞻性单中心研究纳入44例有腰椎MRI临床指征的患者,比较深度学习重建T2 Dixon序列(T2DL)与标准T2 Dixon序列(T2std)的图像质量和采集时间。结果显示T2DL在1.5-T和3-T下采集时间分别缩短60.4%和66.5%(p<0.01),整体图像质量与T2std相当,噪声更低、锐利度更高,但条带伪影更多,诊断信心无显著差异。
要点
- T2DL序列在1.5-T和3-T下采集时间分别较T2std缩短60.4%和66.5%(p<0.01),所有患者均成功采集。
- T2DL整体图像质量与T2std相当(中位评分均为5分,p=0.57),诊断信心无显著差异(p=0.61)。
- T2DL噪声更低、锐利度更高(均p<0.001),但条带伪影显著多于T2std(p<0.001)。
核心结论
- T2DL序列可行,图像质量与参考标准相当,同时大幅缩短采集时间。
研究设计与样本
- 前瞻性单中心研究,纳入2022年9月至2023年3月间44例有腰椎MRI临床指征的连续患者,使用1.5-T和3-T扫描仪(MAGNETOM Aera和Vida,Siemens Healthineers)及专用脊柱线圈,比较标准临床T2 Dixon序列(T2std)与额外采集的深度学习重建T2 Dixon序列(T2DL)。
关键影像表现/征象
- T2DL采用常规采样模式但平行加速因子更高,经专用研究应用程序重建Dixon水脂分离对比图像后再行常规水脂分离获得水图像。
- T2DL在1.5-T和3-T下总采集时间分别为93秒和86秒,T2std分别为235秒和257秒。
- T2DL噪声评分显著低于T2std(5[4-5] vs 4[3-4],p<0.001),锐利度评分显著高于T2std(5[4-5] vs 4[3-5],p<0.001)。
- T2DL条带伪影评分显著低于T2std(5[2-5] vs 5[4-5],p<0.001),即条带伪影更多。
诊断标准与关键数值
- 图像质量、条带伪影、伪影、锐利度、噪声及诊断信心均采用5分Likert量表评估(1=不可诊断,5=图像质量极佳)。
- 整体图像质量中位评分T2DL为5[3-5],T2std为5[2-5],p=0.57。
- 诊断信心中位评分T2std为5[2-5],T2DL为5[3-5],p=0.61。
- T2DL整体图像质量的读者间一致性κ=0.77,读者内一致性κ=0.8。
临床应用与阅片要点
- T2DL在1.5-T和3-T下均可成功采集,采集时间分别较T2std缩短60.4%和66.5%(p<0.01)。
- 阅片时需注意T2DL条带伪影较T2std更多,但原文报告未对诊断信心产生显著影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the image quality and impact on acquisition time of a novel deep learning based T2 Dixon sequence (T2DL) of the spine.
METHODS: This prospective, single center study included n = 44 consecutive patients with a clinical indication for lumbar MRI at our university radiology department between September 2022 and March 2023. MRI examinations were performed on 1.5-T and 3-T scanners (MAGNETOM Aera and Vida; Siemens Healthineers, Erlangen, Germany) using dedicated spine coils. The MR study protocol consisted of our standard clinical protocol, including a T2 weighted standard Dixon sequence (T2std) and an additional T2DL acquisition. The latter used a conventional sampling pattern with a higher parallel acceleration factor. The individual contrasts acquired for Dixon water-fat separation were then reconstructed using a dedicated research application. After reconstruction of the contrast images from k-space data, a conventional water-fat separation was performed to provide derived water images. Two readers with 6 and 4 years of experience in interpreting MSK imaging, respectively, analyzed the images in a randomized fashion. Regarding overall image quality, banding artifacts, artifacts, sharpness, noise, and diagnostic confidence were analyzed using a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent image quality). Statistical analyses included the Wilcoxon signed-rank test and weighted Cohen's kappa statistics.
RESULTS: Forty-four patients (mean age 53 years (±18), male sex: 39 %) were prospectively included. Thirty-one examinations were performed on 1.5 T and 13 examinations on 3 T scanners. A sequence was successfully acquired in all patients. The total acquisition time of T2DL was 93 s at 1.5-T and 86 s at 3-T, compared to 235 s, and 257 s, respectively for T2std (reduction of acquisition time: 60.4 % at 1.5-T, and 66.5 % at 3-T; p < 0.01). Overall image quality was rated equal for both sequences (median T2DL: 5[3 -5], and median T2std: 5 [2 -5]; p = 0.57). T2DL showed significantly reduced noise levels compared to T2std (5 [4 -5] versus 4 [3 -4]; p < 0.001). In addition, sharpness was rated to be significantly higher in T2DL (5 [4 -5] versus 4 [3 -5]; p < 0.001). Although T2DL displayed significantly more banding artifacts (5 [2 -5] versus 5 [4 -5]; p < 0.001), no significant impact on readers diagnostic confidence between sequences was noted (T2std: 5 [2 -5], and T2DL: 5 [3 -5]; p = 0.61). Substantial inter-reader and intrareader agreement was observed for T2DL overall image quality (κ: 0.77, and κ: 0.8, respectively).
CONCLUSION: T2DL is feasible, yields an image quality comparable to the reference standard while substantially reducing the acquisition time.
引用
- Berkarda Z, Wiedemann S, Wilpert C, et al. Deep learning reconstructed T2-weighted Dixon imaging of the spine: Impact on acquisition time and image quality. Eur J Radiol. 2024. PMID: 39067266. doi:10.1016/j.ejrad.2024.111633
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。