回顾性分析29例腰椎MRI患者,比较使用与不使用基于k空间数据的超分辨率深度学习重建(SR-DLR)的图像质量。SR-DLR组椎体与椎管SNR、对比度、CNR及轮廓曲线半峰斜率均显著提高,两名放射科医师的主观评分(噪声、对比度、伪影、锐利度、整体图像质量)也优于未使用SR-DLR组。结论认为SR-DLR有潜力提升基于3D梯度回波同相位序列的腰椎MR骨成像质量。
要点
- SR-DLR可显著提高腰椎MR骨成像的椎体和椎管SNR及对比噪声比。
- SR-DLR能改善图像锐利度、降低噪声、减少伪影并提升整体图像质量主观评分。
- 两名医师对噪声、对比度、锐利度等评分的一致性为中等至良好(κ=0.44~0.76)。
核心结论
- 基于k空间数据的SR-DLR有潜力提升采用3D梯度回波同相位序列的腰椎MR骨成像图像质量。
研究设计与样本
- 回顾性研究,纳入2023年1月至4月间行腰椎MRI(含MR骨成像序列)的29例患者,图像分别采用SR-DLR(矩阵960×960)和不采用SR-DLR(矩阵320×320)重建,比较定量指标及两名放射科医师的4分制主观评分。
诊断标准与关键数值
- SR-DLR组椎体和椎管SNR较无SR-DLR组显著提高(p<0.001);椎体与椎管对比度显著提高(p=0.023);CNR显著提高(p=0.022);椎体后缘轮廓曲线半峰斜率显著提高(p<0.001);主观评分:噪声p<0.001、对比度p<0.001、伪影p=0.042、锐利度p<0.001、整体图像质量p<0.001,均以SR-DLR组更优;观察者间加权kappa:噪声κ=0.56、对比度κ=0.51、伪影κ=0.46、锐利度κ=0.76、整体图像质量κ=0.44。
临床应用与阅片要点
- SR-DLR可提升腰椎MR骨成像的椎体与椎管结构显示质量,阅片时可关注其改善噪声、对比度、锐利度及整体图像质量的效果。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aims to assess the effectiveness of super-resolution deep-learning-based reconstruction (SR-DLR), which leverages k-space data, on the image quality of lumbar spine magnetic resonance (MR) bone imaging using a 3D multi-echo in-phase sequence.
MATERIALS AND METHODS: In this retrospective study, 29 patients who underwent lumbar spine MRI, including an MR bone imaging sequence between January and April 2023, were analyzed. Images were reconstructed with and without SR-DLR (Matrix sizes: 960 × 960 and 320 × 320, respectively). The signal-to-noise ratio (SNR) of the vertebral body and spinal canal and the contrast and contrast-to-noise ratio (CNR) between the vertebral body and spinal canal were quantitatively evaluated. Furthermore, the slope at half-peak points of the profile curve drawn across the posterior border of the vertebral body was calculated. Two radiologists independently assessed image noise, contrast, artifacts, sharpness, and overall image quality of both image types using a 4-point scale. Interobserver agreement was evaluated using weighted kappa coefficients, and quantitative and qualitative scores were compared via the Wilcoxon signed-rank test.
RESULTS: SNRs of the vertebral body and spinal canal were notably improved in images with SR-DLR (p < 0.001). Contrast and CNR were significantly enhanced with SR-DLR compared to those without SR-DLR (p = 0.023 and p = 0.022, respectively). The slope of the profile curve at half-peak points across the posterior border of the vertebral body and spinal canal was markedly higher with SR-DLR (p < 0.001). Qualitative scores (noise: p < 0.001, contrast: p < 0.001, artifact p = 0.042, sharpness: p < 0.001, overall image quality: p < 0.001) were superior in images with SR-DLR compared to those without. Kappa analysis indicated moderate to good agreement (noise: κ = 0.56, contrast: κ = 0.51, artifact: κ = 0.46, sharpness: κ = 0.76, overall image quality: κ = 0.44).
CONCLUSION: SR-DLR, which is based on k-space data, has the potential to enhance the image quality of lumbar spine MR bone imaging utilizing a 3D gradient echo in-phase sequence.
CLINICAL RELEVANCE STATEMENT: The application of SR-DLR can lead to improvements in lumbar spine MR bone imaging quality.
引用
- Hokamura M, Nakaura T, Yoshida N, et al. Super-resolution deep learning reconstruction approach for enhanced visualization in lumbar spine MR bone imaging. Eur J Radiol. 2024. PMID: 39002269. doi:10.1016/j.ejrad.2024.111587
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。