研究纳入24例甲状腺乳头状癌患者的95枚颈侧区淋巴结(49枚转移、46枚非转移),比较40-100 keV虚拟单能图像、120 keV虚拟单能图像与常规120 kVp多能图像的主观图像质量及信噪比、对比噪声比,并评估各图像动脉强化分数诊断转移性淋巴结的效能。40 keV虚拟单能图像信噪比和对比噪声比最高、动脉期图像质量最佳;其动脉强化分数诊断转移性颈侧区淋巴结的曲线下面积为0.878、敏感度87.8%、特异度80.4%。

要点

  • 40 keV虚拟单能图像在动脉期和静脉期信噪比、对比噪声比均显著高于70-100 keV虚拟单能图像、120 keV虚拟单能图像及120 kVp多能图像(均p<0.05)。
  • 各图像组中转移性淋巴结的动脉强化分数均显著高于非转移性淋巴结(均p<0.05)。
  • 40 keV虚拟单能图像动脉强化分数诊断转移性颈侧区淋巴结的曲线下面积为0.878、敏感度87.8%、特异度80.4%。

核心结论

  • 40 keV虚拟单能图像可能最适合显示和诊断甲状腺乳头状癌患者的转移性颈侧区淋巴结。

研究设计与样本

  • 回顾性分析24例甲状腺乳头状癌患者(16例女性,平均年龄40.0±13.4岁)的95枚颈侧区淋巴结(49枚转移、46枚非转移),重建40-100 keV虚拟单能图像、120 keV虚拟单能图像和常规120 kVp多能图像,以病理为参考标准。

关键影像表现/征象

  • 40 keV虚拟单能图像在动脉期和静脉期信噪比、对比噪声比均显著高于70-100 keV虚拟单能图像、120 keV虚拟单能图像及120 kVp多能图像(均p<0.05)。
  • 40 keV虚拟单能图像动脉期图像质量优于70-100 keV虚拟单能图像、120 keV虚拟单能图像及120 kVp多能图像(均p<0.05)。
  • 各图像组中转移性淋巴结的动脉强化分数均显著高于非转移性淋巴结(均p<0.05)。

诊断标准与关键数值

  • 40 keV虚拟单能图像动脉强化分数诊断转移性颈侧区淋巴结:曲线下面积0.878、敏感度87.8%、特异度80.4%。
  • 120 kVp多能图像动脉强化分数诊断转移性颈侧区淋巴结:曲线下面积0.815,与40 keV虚拟单能图像比较p=0.154。

临床应用与阅片要点

  • 在双能谱探测器CT中,40 keV虚拟单能图像可能最适合用于显示和诊断甲状腺乳头状癌患者的转移性颈侧区淋巴结。
  • 动脉强化分数可基于各虚拟单能图像及120 kVp多能图像计算,转移性淋巴结的动脉强化分数高于非转移性淋巴结。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the optimal virtual monochromatic images (VMIs) from dual-layer spectral detector computed tomography for the visualization and diagnosis of metastatic lateral cervical lymph nodes (LNs) in patients with papillary thyroid carcinoma (PTC).

METHODS: Ninety-five lateral cervical LNs (49 metastatic and 46 non-metastatic) derived from 24 patients (16 females; mean age, 40.0 ± 13.4 years) were included. 40-100 kiloelectron voltage (keV) VMIs, 120 keV VMI and conventional 120 kV peak (kVp) polyenergetic image (PI) were reconstructed. Five-point scale of subjective image quality, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of LNs were assessed and compared among each VMI and 120 kVp PI. Receiver operating characteristic (ROC) curves and Delong tests were used to assess and compare the diagnostic efficacy of arterial enhancement fraction (AEF) based on each VMI and 120 kVp PI.

RESULTS: 40 keV VMI showed significantly higher SNR and CNR in both arterial and venous phases, and better image quality in arterial phase than 70-100 keV VMIs, 120 keV VMI, and 120 kVp PI (all p < 0.05). In all sets of images, AEF values of metastatic LNs were significantly higher than those of non-metastatic LNs (all p < 0.05). When using AEF value of 40 keV VMI to diagnose metastatic lateral cervical LNs, an area under ROC curve (AUC) of 0.878, sensitivity of 87.8 % and specificity of 80.4 % could be obtained, while the AUC of AEF value of 120 kVp PI was 0.815 (p = 0.154).

CONCLUSION: 40 keV VMI might be optimal for displaying and diagnosing the metastatic lateral cervical LNs in patients with PTC.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Xu YK, Chai TT, Wang JW, et al. Optimal virtual monochromatic images for assessing metastatic lateral cervical lymph nodes in patients with papillary thyroid carcinoma using dual‑layer spectral detector computed tomography. Eur J Radiol. 2024. PMID: 39018649. doi:10.1016/j.ejrad.2024.111623

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。