乳腺X线摄影联合人工智能在致密型乳腺中的筛查效果:与补充超声筛查的对比研究
本回顾性研究纳入5707例致密型乳腺的无症状女性,比较单纯乳腺X线摄影、联合人工智能(AI)及联合补充超声三种筛查方式的效能。AI辅助提高了乳腺X线摄影的特异度(95.3% vs 94.3%)并降低了异常判读率(5.0% vs 6.0%);联合超声较AI辅助乳腺X线摄影提高了癌检出率(5.6 vs 3.5/1000)和敏感度(97.0% vs 60.6%),但特异度降低(77.6% vs 95.3%)、异常判读率升高(22.9% vs 5.0%)。补充超声额外检出12例癌症,其中92%(11/12)为0期和I期。
要点
- AI辅助乳腺X线摄影较单纯乳腺X线摄影特异度更高(95.3% vs 94.3%),异常判读率更低(5.0% vs 6.0%)。
- 联合超声较AI辅助乳腺X线摄影癌检出率更高(5.6 vs 3.5/1000),敏感度更高(97.0% vs 60.6%)。
- 补充超声额外检出12例癌症,其中92%(11/12)为0期和I期。
核心结论
- AI提高了乳腺X线摄影判读的特异度,但联合补充超声有助于检出更多AI辅助乳腺X线摄影未检出的淋巴结阴性早期乳腺癌。
研究设计与样本
- 回顾性数据库检索,纳入2017年1月至2018年12月在一家初级卫生保健中心连续接受乳腺X线摄影联合全乳手持超声检查的≥40岁致密型乳腺无症状女性5707例(平均年龄52.4岁±7.9)。
诊断标准与关键数值
- 以组织学检查和1年随访数据为参考标准;单纯乳腺X线摄影、AI辅助乳腺X线摄影、乳腺X线摄影联合超声的癌检出率分别为3.5/1000、3.5/1000、5.6/1000。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Comparative performance between artificial intelligence (AI) and breast US for women with dense breasts undergoing screening mammography remains unclear. Purpose To compare the performance of mammography alone, mammography with AI, and mammography plus supplemental US for screening women with dense breasts, and to investigate the characteristics of the detected cancers. Materials and Methods A retrospective database search identified consecutive asymptomatic women (≥40 years of age) with dense breasts who underwent mammography plus supplemental whole-breast handheld US from January 2017 to December 2018 at a primary health care center. Sequential reading for mammography alone and mammography with the aid of an AI system was conducted by five breast radiologists, and their recall decisions were recorded. Results of the combined mammography and US examinations were collected from the database. A dedicated breast radiologist reviewed marks for mammography alone or with AI to confirm lesion identification. The reference standard was histologic examination and 1-year follow-up data. The cancer detection rate (CDR) per 1000 screening examinations, sensitivity, specificity, and abnormal interpretation rate (AIR) of mammography alone, mammography with AI, and mammography plus US were compared. Results Among 5707 asymptomatic women (mean age, 52.4 years ± 7.9 [SD]), 33 (0.6%) had cancer (median lesion size, 0.7 cm). Mammography with AI had a higher specificity (95.3% [95% CI: 94.7, 95.8], P = .003) and lower AIR (5.0% [95% CI: 4.5, 5.6], P = .004) than mammography alone (94.3% [95% CI: 93.6, 94.8] and 6.0% [95% CI: 5.4, 6.7], respectively). Mammography plus US had a higher CDR (5.6 vs 3.5 per 1000 examinations, P = .002) and sensitivity (97.0% vs 60.6%, P = .002) but lower specificity (77.6% vs 95.3%, P < .001) and higher AIR (22.9% vs 5.0%, P < .001) than mammography with AI. Supplemental US alone helped detect 12 cancers, mostly stage 0 and I (92%, 11 of 12). Conclusion Although AI improved the specificity of mammography interpretation, mammography plus supplemental US helped detect more node-negative early breast cancers that were undetected using mammography with AI. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Whitman and Destounis in this issue.
引用
- Ha SM, Jang MJ, Youn I, et al. Screening Outcomes of Mammography with AI in Dense Breasts: A Comparative Study with Supplemental Screening US. Radiology. 2024. PMID: 39041940. doi:10.1148/radiol.233391
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。