乳腺MRI自动背景实质强化评估不同方法的个体内比较:呼吁标准化
该研究对3207例患者共5773次乳腺MRI检查进行伪前瞻性分析,比较四种自动定量背景实质强化(BPE)方法与放射科医生视觉分类的相关性及一致性。基于强化强度的方法与医生分类相关性(0.56、0.55)高于基于强化体积的方法(0.52、0.50),不同方法间相关性差异有统计学意义(P < .001),方法D在区分有无抗激素治疗方面准确度最高(P = .01)。结论认为不同定量BPE方法之间及与医生视觉分类仅呈中等一致性,强度法较体积法与医生评分更接近。
要点
- 基于强化强度的BPE定量方法与放射科医生视觉分类相关性(0.56、0.55)高于基于强化体积的方法(0.52、0.50)。
- 四种自动定量BPE方法之间的相关性差异有统计学意义(P < .001),提示方法间不可互换。
- 方法D在区分接受与未接受抗激素治疗的前绝经期女性方面准确度最高(P = .01)。
核心结论
- 不同定量BPE评估方法之间及与有经验放射科医生视觉分类之间仅呈中等一致性;基于强化强度的方法较基于强化体积的方法与医生评分相关性更高。
研究设计与样本
- 对3207例患者(平均年龄60岁±10[标准差])共5773次乳腺MRI检查进行伪前瞻性分析,由有乳腺MRI经验的放射科医生按BI-RADS前瞻性分类BPE水平。
诊断标准与关键数值
- 基于强化强度的方法A和B与医生分类的相关系数分别为0.56±0.01和0.55±0.01,基于强化体积的方法C和D分别为0.52±0.01和0.50±0.01(P < .001)。
临床应用与阅片要点
- 不同自动定量BPE方法之间及与医生视觉分类仅呈中等一致性,基于强化强度的方法与医生评分相关性更高。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background The level of background parenchymal enhancement (BPE) at breast MRI provides predictive and prognostic information and can have diagnostic implications. However, there is a lack of standardization regarding BPE assessment. Purpose To investigate how well results of quantitative BPE assessment methods correlate among themselves and with assessments made by radiologists experienced in breast MRI. Materials and Methods In this pseudoprospective analysis of 5773 breast MRI examinations from 3207 patients (mean age, 60 years ± 10 [SD]), the level of BPE was prospectively categorized according to the Breast Imaging Reporting and Data System by radiologists experienced in breast MRI. For automated extraction of BPE, fibroglandular tissue (FGT) was segmented in an automated pipeline. Four different published methods for automated quantitative BPE extractions were used: two methods (A and B) based on enhancement intensity and two methods (C and D) based on the volume of enhanced FGT. The results from all methods were correlated, and agreement was investigated in comparison with the respective radiologist-based categorization. For surrogate validation of BPE assessment, how accurately the methods distinguished premenopausal women with (n = 50) versus without (n = 896) antihormonal treatment was determined. Results Intensity-based methods (A and B) exhibited a correlation with radiologist-based categorization of 0.56 ± 0.01 and 0.55 ± 0.01, respectively, and volume-based methods (C and D) had a correlation of 0.52 ± 0.01 and 0.50 ± 0.01 (P < .001). There were notable correlation differences (P < .001) between the BPE determined with the four methods. Among the four quantitation methods, method D offered the highest accuracy for distinguishing women with versus without antihormonal therapy (P = .01). Conclusion Results of different methods for quantitative BPE assessment agree only moderately among themselves or with visual categories reported by experienced radiologists; intensity-based methods correlate more closely with radiologists' ratings than volume-based methods. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Mann in this issue.
引用
- Müller-Franzes G, Khader F, Tayebi Arasteh S, et al. Intraindividual Comparison of Different Methods for Automated BPE Assessment at Breast MRI: A Call for Standardization. Radiology. 2024. PMID: 39012249. doi:10.1148/radiol.232304
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。