非增强螺旋乳腺CT利用病灶密度辅助乳腺癌检测的潜力:一项先导研究

Potential of non-contrast spiral breast CT to exploit lesion density and favor breast cancer detection: A pilot study.
PubMed 文献 · Eur J Radiol · 2024-07-14

这项前瞻性先导研究纳入40例接受非增强螺旋乳腺CT的女性,评估乳腺病灶与乳腺组织的密度值。恶性病灶中位密度高于纤维腺瘤、囊肿及极度致密乳腺组织,两位读者间一致性ICC为0.978,ROC分析显示恶性病灶与其他病变鉴别AUC达0.925-0.942。

要点

  • 非增强螺旋乳腺CT上恶性病灶中位密度60.2-62.5 HU,高于纤维腺瘤、囊肿和极度致密乳腺组织。
  • 恶性病灶与极度致密乳腺组织、囊肿的密度差异有统计学意义(p<0.001)。
  • 两位读者间密度测量一致性ICC为0.978,读者内一致性>0.879。

核心结论

  • 在非增强螺旋乳腺CT上,恶性病灶的密度值高于正常组织和良性病变,且密度测量在不同读者间可重复。

研究设计与样本

  • 前瞻性先导研究,纳入2023年4月至10月因任何目的接受非增强螺旋乳腺CT的女性40例,包括组织学证实的恶性病灶12例、纤维腺瘤10例、超声证实的囊肿15例及无超声发现的极度致密乳腺9例;每例病灶和极度致密乳腺区域各放置3个感兴趣区,由两位读者(R1和R2)评估,采用Kruskal-Wallis检验、组内相关系数(ICC)和ROC分析。

诊断标准与关键数值

  • 恶性病灶中位密度(四分位距):R1为60.2(53.3-67.3)HU,R2为62.5(55.67-76.3)HU。
  • 纤维腺瘤中位密度:R1为46.3(41.9-59.5)HU,R2为44.5(40.5-59.8)HU。
  • 囊肿中位密度:R1为35.3(24.3-46.0)HU,R2为39.7(26.7-52.0)HU。
  • 极度致密乳腺组织中位密度:R1为28.7(24.2-33.0)HU,R2为33.3(31.7-36.8)HU。
  • 恶性病灶与其他病变比较AUC:R1为0.925(95%CI 0.858-0.993),R2为0.942(95%CI 0.884-1.00);恶性病灶与纤维腺瘤比较AUC:R1为0.792(95%CI 0.596-0.987),R2为0.833(95%CI 0.659-1)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the density values of breast lesions and breast tissue using non-contrast spiral breast CT (nc-SBCT) imaging.

METHOD: In this prospective study women undergoing nc-SBCT between April-October 2023 for any purpose were included in case of: histologically proven malignant lesion (ML); fibroadenoma (FA) with histologic confirmation or stability > 24 months (retrospectively); cysts with ultrasound correlation; and women with extremely dense breast (EDB) and no sonographic findings. Three regions of interest were placed on each lesion and 3 different area of EDB. The evaluation was performed by two readers (R1 and R2). Kruskal-Wallis test, intraclass correlation (ICC) and ROC analysis were used.

RESULTS: 40 women with 12 ML, 10 FA, 15 cysts and 9 with EDB were included. Median density values and interquartile ranges for R1 and R2 were: 60.2 (53.3-67.3) and 62.5 (55.67-76.3) HU for ML; 46.3 (41.9-59.5) and 44.5 (40.5-59.8) HU for FA; 35.3 (24.3-46.0) and 39.7 (26.7-52.0) HU for cysts; and 28.7 (24.2-33.0) and 33.3 (31.7-36.8) HU for EDB. For both readers, densities were significantly different for ML versus EDB (p < 0.001) and cysts (p < 0.001) and for FA versus EDB (p=/<0.003). The AUC was 0.925 (95 %CI 0.858-0.993) for R1 and 0.942 (0.884-1.00) for R2 when comparing ML versus others and 0.792 (0.596-0.987) and 0.833 (0.659-1) when comparing ML versus FA. The ICC showed an almost perfect inter-reader (0.978) and intra-reader agreement (>0.879 for both readers).

CONCLUSIONS: In nc-SBCT malignant lesions have higher density values compared to normal tissue and measurements of density values are reproducible between different readers.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Weber J, Zanetti G, Nikolova E, et al. Potential of non-contrast spiral breast CT to exploit lesion density and favor breast cancer detection: A pilot study. Eur J Radiol. 2024. PMID: 39018650. doi:10.1016/j.ejrad.2024.111614

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。