文献速递妇产影像泌尿生殖US

日本女性中由妇科受训医师与超声专科医师应用IOTA ADNEX模型的验证:一项回顾性诊断准确性研究

Validation of the IOTA ADNEX Model Among Japanese Women Performed by Gynecology Trainees and Ultrasound Specialists: A Retrospective Diagnostic Accuracy Study.
PubMed 文献 · J Ultrasound Med · 2024-07-02

本单中心回顾性研究分析2017年1月至2020年3月206例日本附件肿块女性的超声数据,验证IOTA ADNEX模型鉴别良恶性的诊断准确性。总体AUC为0.848(95%CI:0.817-0.880),各检查者AUC范围0.791-0.898,四名检查者间Fleiss kappa为0.586,受训医师与专科医师在评估实性组织和乳头状突起的表现上差异有统计学意义(P<.001)。

要点

  • IOTA ADNEX模型在日本女性附件肿块中总体AUC为0.848(95%CI:0.817-0.880)。
  • 四名检查者间一致性为中等(Fleiss kappa=0.586)。
  • 受训医师与专科医师评估实性组织和乳头状突起时差异显著(P<.001)。

核心结论

  • IOTA ADNEX模型可有效鉴别日本女性附件肿块的良恶性,但受训医师与专科医师在评估实性组织和乳头状突起方面的表现存在显著差异,通过培训有望提高准确性。

研究设计与样本

  • 单中心回顾性诊断准确性研究,纳入2017年1月至2020年3月206例接受超声检查和血清CA-125测量且获得术后组织学诊断的附件肿块女性,由两名受训医师和两名专科医师分别应用ADNEX模型评估。

关键影像表现/征象

  • 研究评估了附件肿块的超声特征,包括实性组织和乳头状突起,但原文未报告具体的影像征象描述。

诊断标准与关键数值

  • 总体鉴别恶性的AUC为0.848(95%CI:0.817-0.880),恶性患病率为30.1%(包括交界性病例)。
  • 各检查者AUC范围为0.791至0.898,专科医师2准确性最高,敏感度范围为0.677至0.839。
  • 四名检查者间Fleiss kappa为0.586,一致性为中等。
  • 受训医师与专科医师在评估实性组织和乳头状突起时差异有统计学意义(P<.001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to validate the diagnostic accuracy of the International Ovarian Tumor Analysis (IOTA) Assessment of Different NEoplasias in the adneXa (ADNEX) model in Japanese women, population with a distinct adnexal mass distribution compared with European women, and to evaluate the model's utility by gynecology trainees and ultrasound specialists.

METHODS: This single-center, retrospective study analyzed ultrasound data from January 2017 to March 2020 of 206 women with adnexal masses. Patients who underwent ultrasonography and serum CA-125 measurement and received postsurgery histological diagnosis were included. The ADNEX model's diagnostic performance was evaluated by two trainees and two specialists using the area under the receiver operating characteristic curve (AUC) and measures of accuracy, sensitivity, specificity, and predictive values for overall performance and each examiner.

RESULTS: Of the 206 included Japanese women, the prevalence of malignancy was 30.1%, including borderline cases. The overall AUC for distinguishing malignancy was 0.848 (95% confidence interval [CI]: 0.817-0.880). The AUC for each examiner ranged from 0.791 to 0.898, with Specialist 2 showing the highest accuracy and sensitivity varying between 0.677 and 0.839. A moderate degree of agreement was noted among the four examiners (Fleiss' kappa was 0.586). The performance of trainees and specialists differed significantly in evaluating the solid tissue and the papillary projections in both malignant and benign groups (P < .001).

CONCLUSIONS: The IOTA ADNEX model effectively differentiates benign and malignant adnexal masses in Japanese women. Although the accuracy matched up moderately among the four examiners, better accuracy is expected with training in evaluating solid tissue and papillary projections.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Kadooka M, Suemitsu T, Ashimoto K, et al. Validation of the IOTA ADNEX Model Among Japanese Women Performed by Gynecology Trainees and Ultrasound Specialists: A Retrospective Diagnostic Accuracy Study. J Ultrasound Med. 2024. PMID: 38953408. doi:10.1002/jum.16517

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。