基于时间依赖性扩散MRI的微结构映射用于鉴别高级别浆液性卵巢癌与浆液性交界性卵巢肿瘤
回顾性纳入34例高级别浆液性卵巢癌与12例浆液性交界性卵巢肿瘤患者,术前行盆腔MRI,采用IMPULSED模型提取细胞内组分分数、细胞直径、细胞密度及细胞外扩散系数,并与标准DWI的ADC比较鉴别诊断效能。结果显示细胞内组分分数、细胞密度、细胞外扩散系数及ADC的AUC分别为0.936、0.909、0.902和0.914,各参数间诊断效能无显著差异;在高级别浆液性卵巢癌组中,细胞密度与P53表达呈显著正相关(P=0.028,r=0.389),细胞外扩散系数与Pax-8表达呈显著正相关(P=0.018,r=0.415)。结论认为时间依赖性扩散MRI可用于评估两种肿瘤的微结构并鉴别二者。
要点
- 细胞内组分分数鉴别高级别浆液性卵巢癌与浆液性交界性卵巢肿瘤的AUC为0.936。
- 细胞密度、细胞外扩散系数及ADC的AUC分别为0.909、0.902和0.914,各参数间无显著差异。
- 高级别浆液性卵巢癌组细胞密度与P53表达正相关(P=0.028,r=0.389)。
核心结论
- 时间依赖性扩散MRI可用于评估高级别浆液性卵巢癌与浆液性交界性卵巢肿瘤的微结构,并能鉴别这两种肿瘤。
研究设计与样本
- 回顾性纳入34例高级别浆液性卵巢癌和12例浆液性交界性卵巢肿瘤病例,术前接受盆腔MRI检查。
关键影像表现/征象
- 由两位放射科医师勾画肿瘤获得感兴趣区,时间依赖性扩散MRI信号采用IMPULSED模型拟合。
- 提取的微结构参数包括细胞内组分分数、细胞直径、细胞密度和细胞外扩散系数。
- ADC值由标准扩散加权成像获得,用于与微结构参数比较。
诊断标准与关键数值
- 细胞内组分分数鉴别高级别浆液性卵巢癌与浆液性交界性卵巢肿瘤的AUC为0.936。
- 细胞密度鉴别二者的AUC为0.909。
- 细胞外扩散系数鉴别二者的AUC为0.902。
- ADC鉴别二者的AUC为0.914。
- 上述参数间诊断效能无显著差异;ICC显示所有参数一致性极好。
临床应用与阅片要点
- 时间依赖性扩散MRI衍生的微结构参数可用于鉴别高级别浆液性卵巢癌与浆液性交界性卵巢肿瘤。
- 在高级别浆液性卵巢癌组中,细胞密度与P53表达呈显著正相关(P=0.028,r=0.389)。
- 在高级别浆液性卵巢癌组中,细胞外扩散系数与Pax-8表达呈显著正相关(P=0.018,r=0.415)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the value of microstructural characteristics derived from time-dependent diffusion MRI in distinguishing high-grade serous ovarian cancer (HGSOC) from serous borderline ovarian tumor (SBOT) and the associations of immunohistochemical markers with microstructural features.
METHODS: Totally 34 HGSOC and 12 SBOT cases who received preoperative pelvic MRI were retrospectively included in this study. Two radiologists delineated the tumors to obtain the regions of interest (ROIs). Time-dependent diffusion MRI signals were fitted by the IMPULSED (imaging microstructural parameters using limited spectrally edited diffusion) model, to extract microstructural parameters, including fraction of the intracellular component (fin), cell diameter (d), cellularity and extracellular diffusivity (Dex). Apparent diffusion coefficient (ADC) values were obtained from standard diffusion-weighted imaging (DWI). The parameters of HGSOCs and SBOTs were compared, and the diagnostic performance was evaluated. The associations of microstructural indexes with immunopathological parameters were assessed, including Ki-67, P53, Pax-8, ER and PR.
RESULTS: In this study, fin, cellularity, Dex and ADC had good diagnostic performance levels in differentiating HGSOC from SBOT, with AUCs of 0.936, 0.909, 0.902 and 0.914, respectively. There were no significant differences in diagnostic performance among these parameters. Spearman analysis revealed in the HGSOC group, cellularity had a significant positive correlation with P53 expression (P = 0.028, r = 0.389) and Dex had a significant positive correlation with Pax-8 expression (P = 0.018, r = 0.415). ICC showed excellent agreement for all parameters.
CONCLUSION: Time-dependent diffusion MRI had value in evaluating the microstructures of HGSOC and SBOT and could discriminate between these tumors.
引用
- Cao Y, Lu Y, Shao W, et al. Time-dependent diffusion MRI-based microstructural mapping for differentiating high-grade serous ovarian cancer from serous borderline ovarian tumor. Eur J Radiol. 2024. PMID: 39018648. doi:10.1016/j.ejrad.2024.111622
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。