文献速递泌尿生殖腹部MR

膀胱癌多参数MRI中二维与三维T2加权成像评估肌层浸润准确性的前瞻性比较:基于VI-RADS

Prospective Comparison of 2D and 3D T2-Weighted Imaging in Multiparametric MRI for Assessing Muscle Invasion Accuracy Using VI-RADS in Bladder Cancer.
PubMed 文献 · Acad Radiol · 2024-07-22

前瞻性纳入101例膀胱癌患者,对比3D与2D T2WI的图像质量及基于VI-RADS诊断肌层浸润的效能;3D T2WI整体图像质量评分更高、伪影更少,两位读者AUC均更高,但VI-RADS分类的AUC在2D与3D方案间无显著差异。

要点

  • 3D T2WI整体图像质量评分显著优于2D T2WI且伪影更少。
  • 两位读者3D T2WI的AUC均显著高于2D T2WI(读者1:0.937 vs. 0.909;读者2:0.923 vs. 0.884)。
  • 3D MR方案VI-RADS评分准确率高于2D MR方案,但两者VI-RADS分类AUC无显著差异。

核心结论

  • 在评估膀胱癌肌层浸润方面,3D T2WI的整体图像质量和诊断效能优于2D T2WI,但3D T2WI并未显著提高VI-RADS的诊断效能。

研究设计与样本

  • 前瞻性研究,2022年8月至2023年5月纳入101例膀胱癌患者,均行包含3D与2D T2WI的多参数MRI。
  • 两位放射科医师独立阅片,评估图像质量并基于VI-RADS评分判断肌层浸润。
  • 采用配对Wilcoxon符号秩检验比较2D与3D T2WI差异,以ROC曲线下面积(AUC)比较诊断效能。

关键影像表现/征象

  • 3D T2WI整体图像质量评分显著高于2D T2WI,且伪影更少。

诊断标准与关键数值

  • 读者1:3D T2WI的AUC为0.937,2D T2WI为0.909,p=0.02。
  • 读者2:3D T2WI的AUC为0.923,2D T2WI为0.884,p=0.04。
  • 读者1:3D MR方案VI-RADS评分准确率为0.931,2D MR方案为0.921,p=0.02。
  • 读者2:3D MR方案VI-RADS评分准确率为0.931,2D MR方案为0.911,p=0.02。
  • 2D与3D MR方案VI-RADS分类的AUC值差异均无统计学意义(所有p>0.05)。

临床应用与阅片要点

  • 3D T2WI可作为膀胱癌多参数MRI中评估肌层浸润的T2加权序列,图像质量及诊断效能优于2D T2WI。
  • 基于VI-RADS评分时,3D T2WI并未显著提高VI-RADS分类的诊断效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: T2-weighted imaging (T2WI) is an essential sequence for assessing the staging of bladder cancer. This study aimed to compare the image quality and diagnostic performance of three-dimensional (3D) and two-dimensional (2D) T2WI in diagnosing muscle invasion of bladder cancer using Vesical Imaging Reporting and Data System (VI-RADS).

MATERIALS AND METHODS: Between August 2022 and May 2023, 101 participants with bladder cancer underwent multiparametric MRI including 3D and 2D T2WI. Two radiologists independently reviewed 2D and 3D T2WI, evaluating image quality and muscle invasion based on VI-RADS scoring. The paired Wilcoxon signed-rank test assessed the differences between 2D and 3D T2WI. The areas under the receiver operating characteristic curve (AUCs) were utilized to compare the diagnostic performance.

RESULTS: 3D T2WI demonstrated significantly superior overall image quality scores with less artifacts than 2D T2WI. Compared to 2D T2WI, 3D T2WI categories had significantly higher AUC for both readers (reader 1: 0.937 vs. 0.909, p = .02; reader 2: 0.923 vs.0.884, p = .04). The VI-RADS score of 3D MR protocol had higher accuracy than 2D MR protocol (reader 1: 0.931 vs. 0.921, p = .02; reader 2: 0.931 vs. 0.911, p = .02). However, there were no significant differences in AUC values of VI-RADS categories between 2D and 3D MR protocol (all p > 0.05).

CONCLUSION: In assessing muscle invasion of bladder cancer, 3D T2WI exhibited superior overall image quality and diagnostic performance than 2D T2WI. However, 3D T2WI did not significantly improve the diagnostic performance of VI-RADS.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang X, Wang Y, Xu X, et al. Prospective Comparison of 2D and 3D T2-Weighted Imaging in Multiparametric MRI for Assessing Muscle Invasion Accuracy Using VI-RADS in Bladder Cancer. Acad Radiol. 2024. PMID: 39043518. doi:10.1016/j.acra.2024.07.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。