人工智能辅助压缩感知在前列腺T2加权成像中的可行性研究
这项前瞻性研究纳入40例接受前列腺MRI的成年男性泌尿外科门诊或住院患者,比较基于并行成像(PI)与人工智能辅助压缩感知(ACS)的三种加速T2WI方案(T2WIPI、T2WIACS1、T2WIACS2)。ACS较PI缩短采集时间50%以上,显著提高矢状位和轴位T2WI的CNR及图像质量(P<0.05),斜率轮廓、ERD及PI-RADS评分组间无显著差异(P>0.05)。
要点
- ACS较PI将前列腺T2WI采集时间缩短50%以上。
- ACS显著提高矢状位和轴位T2WI的CNR及图像质量(P<0.05)。
- 斜率轮廓、ERD及PI-RADS评分组间无显著差异(P>0.05)。
核心结论
- ACS将前列腺T2WI采集时间减半并提高图像质量,且不影响PI-RADS评分。
研究设计与样本
- 前瞻性研究,纳入40例接受前列腺MRI的成年男性泌尿外科门诊或住院患者,扫描序列包括T2WI、扩散加权成像和表观扩散系数图,比较T2WIPI、T2WIACS1和T2WIACS2三种加速扫描方案,统计学采用Friedman检验和单因素方差分析及事后检验,P<0.05为差异有统计学意义。
诊断标准与关键数值
- 定量分析包括信噪比(SNR)、对比噪声比(CNR)、斜率轮廓和边缘上升距离(ERD);图像质量采用五点Likert量表定性评估(1=不可诊断,5=极佳);对每例患者最大或最可疑病灶测定PI-RADS评分。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To evaluate the image quality and PI-RADS scoring performance of prostate T2-weighted imaging (T2WI) based on AI-assisted compressed sensing (ACS).
MATERIALS AND METHODS: In this prospective study, adult male urological outpatients or inpatients underwent prostate MRI, including T2WI, diffusion-weighted imaging and apparent diffusion coefficient maps. Three accelerated scanning protocols using parallel imaging (PI) and ACS: T2WIPI, T2WIACS1 and T2WIACS2 were evaluated through comparative analysis. Quantitative analysis included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), slope profile, and edge rise distance (ERD). Image quality was qualitatively assessed using a five-point Likert scale (ranging from 1 = non-diagnostic to 5 = excellent). PI-RADS scores were determined for the largest or most suspicious lesions in each patient. The Friedman test and one-way ANOVA with post hoc tests were utilized for group comparisons, with statistical significance set at P < 0.05.
RESULTS: This study included 40 participants. Compared to PI, ACS reduced acquisition time by over 50%, significantly enhancing the CNR of sagittal and axial T2WI (P < 0.05), significantly improving the image quality of sagittal and axial T2WI (P < 0.05). No significant differences were observed in slope profile, ERD, and PI-RADS scores between groups (P > 0.05).
CONCLUSION: ACS reduced prostate T2WI acquisition time by half while improving image quality without affecting PI-RADS scores.
引用
- Shen L, Xu H, Liao Q, et al. A Feasibility Study of AI-Assisted Compressed Sensing in Prostate T2-Weighted Imaging. Acad Radiol. 2024. PMID: 39068095. doi:10.1016/j.acra.2024.06.048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。