胰腺前瞻性加速MRI深度学习重建:采用Dixon脂肪抑制的缩短屏气检查的临床评估
这项前瞻性单中心研究纳入32例胰腺病变 participant,在1.5 T扫描仪上比较传统VIBE-Dixon与深度学习重建的加速VIBE-Dixon DL。VIBE-Dixon DL使平均屏气时间从15秒降至7秒(降低52%),并显著改善图像锐利度、整体图像质量、诊断信心和胰腺病灶清晰度,同时降低图像噪声和运动伪影。
要点
- VIBE-Dixon DL平均屏气时间7秒,较传统VIBE-Dixon的15秒降低52%(P < 0.001)。
- VIBE-Dixon DL显著改善图像锐利度、整体图像质量、诊断信心及胰腺病灶清晰度(P < 0.001)。
- 两种方法病灶大小测量无差异,读者间一致性ICC > 90。
核心结论
- 前瞻性加速的深度学习增强VIBE联合Dixon脂肪抑制在临床上可行,使屏气时间降低52%,并提供更优的图像质量、诊断信心和胰腺病灶清晰度,该技术可能对屏气能力有限的患者特别有用。
研究设计与样本
- 前瞻性单中心研究,纳入2023年1月至2023年9月间签署书面同意的各种胰腺病变 participant 共32例(平均年龄±SD 62±19岁,20名男性)。
关键影像表现/征象
- VIBE-Dixon DL较VIBE-Dixon显著改善图像锐利度、整体图像质量、诊断信心及胰腺病灶清晰度(P < 0.001)。
- VIBE-Dixon DL较VIBE-Dixon显著降低图像噪声和运动伪影(P < 0.001)。
- 所有读者对两种方法病灶大小测量无差异证据,读者间一致性ICC > 90。
诊断标准与关键数值
- VIBE-Dixon DL平均屏气时间7秒 vs VIBE-Dixon 15秒,降低52%(P < 0.001)。
- VIBE-Dixon DL胰腺SNR在平扫(P = 0.025)和增强后(P < 0.001)均显著升高。
- VIBE-Dixon DL脾SNR在平扫(P = 0.34)未达统计学显著,增强后(P = 0.003)显著升高。
- VIBE-Dixon DL胰腺CNR在平扫(P = 0.557)未达统计学显著,增强后(P = 0.026)显著升高。
- 病灶大小读者间一致性ICC > 90。
临床应用与阅片要点
- VIBE-Dixon DL可在保持病灶大小测量一致性的前提下将屏气时间缩短至7秒,适用于屏气能力有限患者的胰腺MRI检查。
- VIBE-Dixon DL在增强后图像中胰腺SNR和CNR显著提高,阅片时可结合增强后序列评估胰腺病变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Deep learning (DL)-enabled magnetic resonance imaging (MRI) reconstructions can enable shortening of breath-hold examinations and improve image quality by reducing motion artifacts. Prospective studies with DL reconstructions of accelerated MRI of the upper abdomen in the context of pancreatic pathologies are lacking. In a clinical setting, the purpose of this study is to investigate the performance of a novel DL-based reconstruction algorithm in T1-weighted volumetric interpolated breath-hold examinations with partial Fourier sampling and Dixon fat suppression (hereafter, VIBE-Dixon DL ). The objective is to analyze its impact on acquisition time, image sharpness and quality, diagnostic confidence, pancreatic lesion conspicuity, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR).
METHODS: This prospective single-center study included participants with various pancreatic pathologies who gave written consent from January 2023 to September 2023. During the same session, each participant underwent 2 MRI acquisitions using a 1.5 T scanner: conventional precontrast and postcontrast T1-weighted VIBE acquisitions with Dixon fat suppression (VIBE-Dixon, reference standard) using 4-fold parallel imaging acceleration and 6-fold accelerated VIBE-Dixon acquisitions with partial Fourier sampling utilizing a novel DL reconstruction tailored to the acquisition. A qualitative image analysis was performed by 4 readers. Acquisition time, image sharpness, overall image quality, image noise and artifacts, diagnostic confidence, as well as pancreatic lesion conspicuity and size were compared. Furthermore, a quantitative analysis of SNR and CNR was performed.
RESULTS: Thirty-two participants were evaluated (mean age ± SD, 62 ± 19 years; 20 men). The VIBE-Dixon DL method enabled up to 52% reduction in average breath-hold time (7 seconds for VIBE-Dixon DL vs 15 seconds for VIBE-Dixon, P < 0.001). A significant improvement of image sharpness, overall image quality, diagnostic confidence, and pancreatic lesion conspicuity was observed in the images recorded using VIBE-Dixon DL ( P < 0.001). Furthermore, a significant reduction of image noise and motion artifacts was noted in the images recorded using the VIBE-Dixon DL technique ( P < 0.001). In addition, for all readers, there was no evidence of a difference in lesion size measurement between VIBE-Dixon and VIBE-Dixon DL . Interreader agreement between VIBE-Dixon and VIBE-Dixon DL regarding lesion size was excellent (intraclass correlation coefficient, >90). Finally, a statistically significant increase of pancreatic SNR in VIBE-DIXON DL was observed in both the precontrast ( P = 0.025) and postcontrast images ( P < 0.001). Also, an increase of splenic SNR in VIBE-DIXON DL was observed in both the precontrast and postcontrast images, but only reaching statistical significance in the postcontrast images ( P = 0.34 and P = 0.003, respectively). Similarly, an increase of pancreas CNR in VIBE-DIXON DL was observed in both the precontrast and postcontrast images, but only reaching statistical significance in the postcontrast images ( P = 0.557 and P = 0.026, respectively).
CONCLUSIONS: The prospectively accelerated, DL-enhanced VIBE with Dixon fat suppression was clinically feasible. It enabled a 52% reduction in breath-hold time and provided superior image quality, diagnostic confidence, and pancreatic lesion conspicuity. This technique might be especially useful for patients with limited breath-hold capacity.
引用
- Chaika M, Brendel JM, Ursprung S, et al. Deep Learning Reconstruction of Prospectively Accelerated MRI of the Pancreas: Clinical Evaluation of Shortened Breath-Hold Examinations With Dixon Fat Suppression. Invest Radiol. 2024. PMID: 39043213. doi:10.1097/RLI.0000000000001110
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。