文献速递腹部技术与安全MR

腹部MRI中T1加权成像的运动缓解:技术原理、临床应用、当前局限与未来展望

T1-weighted Motion Mitigation in Abdominal MRI: Technical Principles, Clinical Applications, Current Limitations, and Future Prospects.
PubMed 文献 · Radiographics · 2024-01-01

本文综述腹部MRI中T1加权序列的运动缓解技术,包括单次屏气内多次动脉期采集、自由呼吸联合呼吸门控或触发、以及黄金角径向k空间采集(stack-of-stars)等径向采集技术。作者阐述各技术的原理、临床应用与局限,并为屏气能力受限患者提供腹部MRI协议策略的实用指导。

要点

  • T1加权序列是腹部MRI临床协议不可或缺的组成,但通常需要多次屏气,并非所有患者都能维持。
  • 运动缓解技术包括单次屏气内多次动脉期采集、自由呼吸联合呼吸门控或触发、以及黄金角径向k空间采集(stack-of-stars)等径向采集技术。
  • 选择具体运动缓解技术需综合考虑临床任务、下游技术影响、患者状况和用户偏好。

核心结论

  • 作者综述了腹部MRI T1加权序列自由呼吸运动缓解技术的技术原理、已确立的临床应用和现有局限,并为屏气能力受限患者常见临床场景下的腹部MRI协议策略提供实用指导,同时讨论了自由呼吸T1加权腹部MRI的未来前景。

研究设计与样本

  • 综述类文章,检索范围与纳入文献原文未报告;文章回顾腹部MRI T1加权序列自由呼吸运动缓解技术的技术原理、临床应用与局限,并提供协议策略的实用指导。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

T1-weighted (T1W) pulse sequences are an indispensable component of clinical protocols in abdominal MRI but usually require multiple breath holds (BHs) during the examination, which not all patients can sustain. Patient motion can affect the quality of T1W imaging so that key diagnostic information, such as intrinsic signal intensity and contrast enhancement image patterns, cannot be determined. Patient motion also has a negative impact on examination efficiency, as multiple acquisition attempts prolong the duration of the examination and often remain noncontributory. Techniques for mitigation of motion-related artifacts at T1W imaging include multiple arterial acquisitions within one BH; free breathing with respiratory gating or respiratory triggering; and radial imaging acquisition techniques, such as golden-angle radial k-space acquisition (stack-of-stars). While each of these techniques has inherent strengths and limitations, the selection of a specific motion-mitigation technique is based on several factors, including the clinical task under investigation, downstream technical ramifications, patient condition, and user preference. The authors review the technical principles of free-breathing motion mitigation techniques in abdominal MRI with T1W sequences, offer an overview of the established clinical applications, and outline the existing limitations of these techniques. In addition, practical guidance for abdominal MRI protocol strategies commonly encountered in clinical scenarios involving patients with limited BH abilities is rendered. Future prospects of free-breathing T1W imaging in abdominal MRI are also discussed. ©RSNA, 2024 See the invited commentary by Fraum and An in this issue.

来源:Radiographics,查看原文。版权归原作者所有。

引用

  1. Kolokythas O, Yaman Akcicek E, Akcicek H, et al. T1-weighted Motion Mitigation in Abdominal MRI: Technical Principles, Clinical Applications, Current Limitations, and Future Prospects. Radiographics. 2024. PMID: 38990776. doi:10.1148/rg.230173

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。