文献速递腹部外周血管介入CTDSA

减重手术后胃动脉血供的多层CT动脉成像评估

Assessment of arterial supply to the stomach after bariatric surgery using multidetector CT arteriography.
PubMed 文献 · Abdom Radiol (NY) · 2024-07-01

回顾性分析3家学术机构46例(25例Roux-en-Y胃旁路术、21例袖状胃切除术)患者的动脉期CT,评估胃左动脉、胃右动脉、胃网膜动脉及左膈下动脉的通畅性与胃穿支存在情况。结果显示胃左动脉在所有病例中均被识别并见胃穿支供应,作者推荐在再次手术干预前采用专用CT血管成像方案或导管动脉造影全面评估胃血供。

要点

  • 胃左动脉在所有RYGB和SG病例中均被识别,且通畅性优良率达80%以上,并见胃穿支供应。
  • RYGB术后胃网膜动脉胃穿支供应见于83%(19/23),而SG术后未见胃网膜动脉胃穿支供应。
  • 再次手术干预前推荐采用专用CT血管成像方案或导管动脉造影评估胃血供。

核心结论

  • 胃左动脉在所有RYGB和SG病例中均被识别并见胃穿支供应,提示手术方式在保留胃左动脉方面无复杂操作;作者推荐在再次手术干预前采用专用CT血管成像方案或导管动脉造影以准确全面评估胃血供。

研究设计与样本

  • 回顾性研究,纳入3家学术机构46例(25例RYGB、21例SG)患者的动脉期CT,评估胃左动脉、胃右动脉、胃网膜动脉和左膈下动脉的通畅性及胃穿支存在情况。

关键影像表现/征象

  • 平均直径:胃左动脉2.2±0.4 mm,胃右动脉1.6±0.5 mm,胃网膜动脉1.7±0.4 mm。
  • RYGB组:胃左动脉、胃右动脉全部识别,胃网膜动脉识别24/25(96%);通畅性优良率胃左动脉20/25(80%)、胃右动脉21/25(84%)、胃网膜动脉23/24(96%)。
  • SG组:胃左动脉全部识别,胃右动脉识别18/21(86%),胃网膜动脉识别20/21(95%);通畅性优良率胃左动脉17/21(81%)、胃右动脉15/18(83%)、胃网膜动脉20/20(100%)。
  • 胃穿支供应:胃左动脉在RYGB组23/25(92%)、SG组17/17(100%)见供应;胃右动脉在RYGB组13/21(62%)、SG组9/18(50%)见供应;胃网膜动脉在RYGB组19/23(83%)见供应,SG组未见胃网膜动脉胃穿支供应。

诊断标准与关键数值

  • 通畅性分级采用优良至良好(excellent to good)描述,未报告具体分级阈值。
  • 胃穿支存在以动脉期CT显示胃壁供血血管为判定依据,原文未报告敏感度、特异度或AUC。

临床应用与阅片要点

  • 动脉期CT系统评估胃左动脉、胃右动脉、胃网膜动脉和左膈下动脉的通畅性及胃穿支,有助于诊断和治疗术后并发症。
  • 作者推荐在再次手术干预前采用专用CT血管成像方案或导管动脉造影,以准确全面评估胃血供。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To describe residual arterial supply to the stomach after bariatric surgery via a systematic arterial-phase CT assessment approach that can aid in diagnosis and treatment of postoperative complications and facilitate planning for future procedures.

METHODS: Arterial-phase CT of 46 patients who underwent Roux-en-Y gastric bypass (RYGB) or sleeve gastrectomy (SG) at 3 academic institutions were retrospectively reviewed to assess patency of left gastric artery (LGA), right gastric artery (RGA), gastroepiploic artery (GEA), and left inferior phrenic artery (LIPA) and presence of gastric perforators.

RESULTS: In 25 RYGB and 21 SG patients, mean diameters were LGA 2.2 ± 0.4 mm, RGA 1.6 ± 0.5 mm, and GEA 1.7 ± 0.4 mm. On RYGB scans, all LGAs, RGAs, and 24/25 (96%) of GEAs were identified. Excellent to good patency was seen in 20/25 (80%) LGAs, 21/25 (84%) RGAs, and 23/24 (96%) GEAs. On SG scans, all LGAs, 18/21 (86%) of RGAs, and 20/21 (95%) GEAs were identified. Excellent to good patency was seen in 17/21 (81%) LGAs, 15/18 (83%) RGAs, and 20/20 (100%) GEAs. In terms of gastric perforators, LGA supply was seen on 23/25 (92%) of RYGB and 17/17 (100%) of SG scans. RGA supply was seen on 13/21 (62%) RYGB and 9/18 (50%) SG scans. GEA supply was seen on 19/23 (83%) RYGB scans. No gastric supply via GEA was seen on SG scans.

CONCLUSION: In this study, arterial supply to the stomach through the LGA was consistently identified in all RYGB and SG cases, indicating an uncomplicated surgical approach with regard to preserving the LGA. Dedicated CT angiography protocol or catheter-directed angiography is recommended for accurate and comprehensive assessment of the gastric blood supply, particularly before surgical re-intervention.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Khalil A, Gomez E, Gowda PC, et al. Assessment of arterial supply to the stomach after bariatric surgery using multidetector CT arteriography. Abdom Radiol (NY). 2024. PMID: 38951233. doi:10.1007/s00261-024-04467-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。