第二代双层光谱探测器CT运动补偿重建优化冠状动脉CT血管成像质量
回顾性纳入127例疑似冠心病行第二代双层光谱探测器CT冠状动脉CT血管成像的患者,按扫描平均心率分为<75 bpm组和≥75 bpm组,比较标准算法与运动补偿重建算法(MCR)的图像质量。MCR在节段、血管和患者水平的Likert评分和可判读性均显著高于标准算法,客观图像质量(SNR、CNR)也显著改善,高心率组获益更明显。
要点
- MCR较标准算法显著提高CCTA各水平Likert评分和可判读性(均p<0.001)。
- MCR显著改善SNR和CNR(均p<0.001),高心率组运动校正获益更明显。
- 高心率组三支主要冠状动脉可判读性均有显著差异,低心率组仅右冠状动脉有显著差异。
核心结论
- MCR可显著改善第二代双层光谱探测器CT冠状动脉CT血管成像的主观图像质量、可判读性和客观图像质量,高心率患者获益更明显。
研究设计与样本
- 回顾性纳入127例疑似冠心病行第二代双层光谱探测器CT冠状动脉CT血管成像的患者,按扫描平均心率分为<75 bpm组和≥75 bpm组,所有图像分别用标准算法和MCR算法重建,比较全人群及各亚组的主客观图像质量。
诊断标准与关键数值
- 主观图像质量采用4分Likert量表评估,MCR较标准算法在节段水平为3.58 ± 0.69 vs. 2.82 ± 0.93。
- 可判读性在节段水平MCR为98.4% vs. 标准算法91.9%,在血管水平为96.3% vs. 78.7%,在患者水平为90.6% vs. 59.1%(均p<0.001)。
- 客观图像质量MCR较标准算法SNR为13.22 ± 4.06 vs. 12.72 ± 4.06,CNR为15.84 ± 4.82 vs. 15.39 ± 4.38(均p<0.001)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the effect of motion-compensated reconstruction (MCR) algorithm on improving the image quality of coronary computed tomography angiography (CCTA) using second-generation dual-layer spectral detector computed tomography (DLCT), and to evaluate the influence of heart rate (HR) on the motion-correction efficacy of this algorithm.
MATERIALS AND METHODS: We retrospectively enrolled 127 patients who underwent CCTA for suspected coronary artery disease using second-generation DLCT. We divided the patients into two subgroups according to their average HR during scanning: the "HR < 75 bpm" group and the "HR ≥ 75 bpm" group. All images were reconstructed by the standard (STD) algorithm and MCR algorithm. Subjective image quality (4-point Likert scale), interpretability, and objective image quality between the STD and MCR in the whole population and within each subgroup were compared.
RESULTS: MCR showed significantly higher Likert scores and interpretability than STD on the per-segment (3.58 ± 0.69 vs. 2.82 ± 0.93, 98.4% vs. 91.9%), per-vessel (3.12 ± 0.81 vs. 2.12 ± 0.74, 96.3% vs. 78.7%) and per-patient (2.57 ± 0.76 vs. 1.62 ± 0.55, 90.6% vs. 59.1%) levels (all p < 0.001). In the analysis of HR subgroups on a per-vessel basis of interpretability, significant differences were observed only in the right coronary artery in the low HR group, whereas significant differences were noted in three major coronary arteries in the high HR group. For objective image quality assessment, MCR significantly improved the SNR (13.22 ± 4.06 vs. 12.72 ± 4.06) and the contrast-to-noise ratio (15.84 ± 4.82 vs. 15.39 ± 4.38) compared to STD (both p < 0.001).
CONCLUSION: MCR significantly improves the subjective image quality, interpretability, and objective image quality of CCTA, especially in patients with higher HRs.
CLINICAL RELEVANCE STATEMENT: The motion-compensated reconstruction algorithm of the second-generation dual-layer spectral detector computed tomography is helpful in improving the image quality of coronary computed tomography angiography in clinical practice, especially in patients with higher heart rates.
KEY POINTS: Motion artifacts from cardiac movement affect the quality and interpretability of coronary computed tomography angiography (CCTA). This motion-compensated reconstruction (MCR) algorithm significantly improves the image quality of CCTA in clinical practice. Image quality improvement by using MCR was more significant in the high heart rate group.
引用
- Liu S, Huang L, Gui S, et al. Optimizing coronary CT angiography quality with motion-compensated reconstruction for second-generation dual-layer spectral detector CT. Eur Radiol. 2024. PMID: 38987398. doi:10.1007/s00330-024-10908-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。