文献速递外周血管腹部CT

低能量虚拟单能CT联合深度学习图像重建改善内漏勾画

Low energy virtual monochromatic CT with deep learning image reconstruction to improve delineation of endoleaks.
PubMed 文献 · Clin Radiol · 2024-07-09

本研究纳入61例EVAR术后行对比增强双能CT的患者,比较40与70 keV虚拟单能图像分别结合深度学习重建与混合迭代重建对内漏显示的效果。结果显示40 keV联合深度学习重建的内漏对比噪声比及主观显示评分均优于其他重建组合。

要点

  • 40 keV虚拟单能联合深度学习重建可提高内漏的对比噪声比和显示清晰度。
  • 静脉期CT上内漏对比噪声比:40 keV深度学习重建14.5±7.3 vs 混合迭代重建8.6±4.2,P<0.001。
  • 40 keV深度学习重建的内漏显示评分优于70 keV各重建及40 keV混合迭代重建。

核心结论

  • 与70 keV虚拟单能结合混合迭代重建或深度学习重建相比,40 keV虚拟单能联合深度学习重建可改善EVAR术后内漏的勾画。

研究设计与样本

  • 研究纳入61例EVAR术后行对比增强双能CT的连续患者(平均年龄77岁,46例男性),比较40与70 keV虚拟单能图像分别结合深度学习重建(TrueFidelity-H)与混合迭代重建共4组图像。

关键影像表现/征象

  • 静脉期CT上计算内漏的对比噪声比。
  • 4组重建图像并排显示,对内漏显示清晰度进行5分比较评分,从0分(最佳)至-4分(显著较差)。
  • 由两名经验丰富的放射科医师独立进行定性评估。

诊断标准与关键数值

  • 40 keV深度学习重建内漏对比噪声比14.5±7.3 vs 40 keV混合迭代重建8.6±4.2,P<0.001。
  • 70 keV深度学习重建内漏对比噪声比8.7±4.5 vs 70 keV混合迭代重建5.5±2.6,P<0.001。
  • 内漏显示比较评分:40 keV深度学习重建(观察者1 -0.2±0.4;观察者2 0.0±0.0)显著高于40 keV混合迭代重建(观察者1 -0.5±0.5;观察者2 -1.0±0.0;P<0.05)、70 keV深度学习重建(观察者1 -1.8±0.4;观察者2 -2.0±0.0;P<0.001)及70 keV混合迭代重建(观察者1 -1.8±0.4;观察者2 -2.4±0.5;P<0.001)。

临床应用与阅片要点

  • 在EVAR术后对比增强双能CT静脉期阅片时,可采用40 keV虚拟单能联合深度学习重建以提高内漏显示。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: This study aimed to investigate the utility of low-energy virtual monochromatic imaging (VMI) combined with deep-learning image reconstruction (DLIR) in improving the delineation of endoleaks (ELs) after endovascular aortic repair (EVAR) in contrast-enhanced dual-energy CT (DECT).

METHODS: A total of 61 consecutive patients (mean age, 77 years; 46 men) after EVAR who underwent contrast-enhanced DECT were enrolled. Virtual monochromatic 40- and 70-keV images were reconstructed using DLIR (TrueFidelity-H) and conventional hybrid iterative reconstruction (IR). Contrast-to-noise ratio (CNR) of the EL on the venous-phase CT was calculated. Four different reconstructed image series (hybrid IR and DLIR at two energy levels, 40- and 70-keV) were displayed side-by-side and visually assessed for EL conspicuity on a 5-point comparative scale from 0 (best) to -4 (significantly inferior). Two experienced radiologists independently conducted a qualitative evaluation of the CT images.

RESULTS: A total of 30 out of 61 patients presented with an EL. On both 40- and 70-keV images, the CNR of the EL was significantly higher in DLIR than in hybrid IR (40-keV, 14.5 ± 7.3 vs 8.6 ± 4.2, P<0.001; 70-keV, 8.7 ± 4.5 vs 5.5 ± 2.6, P<0.001). The comparative scale of EL conspicuity in the 40-keV DLIR images (Observer1, -0.2 ± 0.4; Observer2, 0.0 ± 0.0) was significantly higher than 40-keV hybrid IR (Observer1, -0.5 ± 0.5; Observer2, -1.0 ± 0.0; P<0.05), 70-keV DLIR (Observer1, -1.8 ± 0.4; Observer2, -2.0 ± 0.0; P<0.001) and 70-keV hybrid IR images (Observer1, -1.8 ± 0.4; Observer2, -2.4 ± 0.5; P<0.001), respectively.

CONCLUSIONS: Using 40-keV VMI in combination with DLIR improves EL delineation after EVAR compared with the 70-keV VMI with hybrid IR or DLIR.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Higashigawa T, Ichikawa Y, Nakajima K, et al. Low energy virtual monochromatic CT with deep learning image reconstruction to improve delineation of endoleaks. Clin Radiol. 2024. PMID: 39079807. doi:10.1016/j.crad.2024.07.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。