文献速递心血管MR

利用数据驱动原生对比映射实现原生T1心脏MRI对慢性心肌梗死的可靠视觉检测

Enabling Reliable Visual Detection of Chronic Myocardial Infarction with Native T1 Cardiac MRI Using Data-Driven Native Contrast Mapping.
PubMed 文献 · Radiol Cardiothorac Imaging · 2024-01-01

研究在24只犬慢性再灌注心肌梗死模型中,用数据驱动机器学习逐像素方法替代常规拟合算法生成原生T1图,评估梗死与远隔心肌对比度。结果显示数据驱动原生映射(DNM)的对比噪声比(15.01 ± 2.88)显著高于原生T1图(5.64 ± 1.58;P < .001),且与晚期钆增强(LGE)相近(15.51 ± 2.43;P = .40);基于LGE的梗死面积与DNM的相关性(R2 = 0.85)强于原生T1图(R2 = 0.71;P < .001)。

要点

  • 犬慢性再灌注梗死模型中,DNM的梗死-远隔心肌对比噪声比(15.01 ± 2.88)显著高于原生T1图(5.64 ± 1.58;P < .001)。
  • DNM对比噪声比与LGE(15.51 ± 2.43)无显著差异(P = .40)。
  • 基于LGE的梗死面积与DNM相关性(R2 = 0.85)强于原生T1图(R2 = 0.71;P < .001)。

核心结论

  • 原生T1加权像素携带的信息可通过所提出的DNM方法提取,以最大化梗死与远隔区域之间的图像对比度,从而增强慢性梗死区域的视觉显示。

研究设计与样本

  • 受控大型动物模型研究,24只犬(雌雄各半)慢性心肌梗死伴组织学异质性梗死组织构成;使用自组织映射和无监督聚类及t分布随机邻域嵌入分析原生T1加权像素强度模式,训练深度神经网络模型将原生T1加权图像系列像素模式映射到LGE图像对应像素,生成数据驱动原生映射(DNM);以LGE为参考标准,用Pearson相关系数和Bland-Altman分析比较DNM与标准T1图。

关键影像表现/征象

  • 原生T1加权图像在梗死区与远隔区之间呈现不同的像素强度模式。
  • 颗粒模式可视化显示,以LGE标注时梗死-远隔聚类可分性高于原生T1图。

诊断标准与关键数值

  • DNM的表观对比噪声比均值15.01 ± 2.88,原生T1图5.64 ± 1.58(P < .001),LGE 15.51 ± 2.43(DNM vs LGE P = .40)。
  • 基于LGE的梗死面积与原生T1图相关性R2 = 0.71,与DNM相关性R2 = 0.85(P < .001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate whether infarct-to-remote myocardial contrast can be optimized by replacing generic fitting algorithms used to obtain native T1 maps with a data-driven machine learning pixel-wise approach in chronic reperfused infarct in a canine model. Materials and Methods A controlled large animal model (24 canines, equal male and female animals) of chronic myocardial infarction with histologic evidence of heterogeneous infarct tissue composition was studied. Unsupervised clustering techniques using self-organizing maps and t-distributed stochastic neighbor embedding were used to analyze and visualize native T1-weighted pixel-intensity patterns. Deep neural network models were trained to map pixel-intensity patterns from native T1-weighted image series to corresponding pixels on late gadolinium enhancement (LGE) images, yielding visually enhanced noncontrast maps, a process referred to as data-driven native mapping (DNM). Pearson correlation coefficients and Bland-Altman analyses were used to compare findings from the DNM approach against standard T1 maps. Results Native T1-weighted images exhibited distinct pixel-intensity patterns between infarcted and remote territories. Granular pattern visualization revealed higher infarct-to-remote cluster separability with LGE labeling as compared with native T1 maps. Apparent contrast-to-noise ratio from DNM (mean, 15.01 ± 2.88 [SD]) was significantly different from native T1 maps (5.64 ± 1.58; P < .001) but similar to LGE contrast-to-noise ratio (15.51 ± 2.43; P = .40). Infarcted areas based on LGE were more strongly correlated with DNM compared with native T1 maps (R2 = 0.71 for native T1 maps vs LGE; R2 = 0.85 for DNM vs LGE; P < .001). Conclusion Native T1-weighted pixels carry information that can be extracted with the proposed DNM approach to maximize image contrast between infarct and remote territories for enhanced visualization of chronic infarct territories. Keywords: Chronic Myocardial Infarction, Cardiac MRI, Data-Driven Native Contrast Mapping Supplemental material is available for this article. © RSNA, 2024.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Youssef K, Zhang X, Yoosefian G, et al. Enabling Reliable Visual Detection of Chronic Myocardial Infarction with Native T1 Cardiac MRI Using Data-Driven Native Contrast Mapping. Radiol Cardiothorac Imaging. 2024. PMID: 39023374. doi:10.1148/ryct.230338

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。