文献速递心血管外周血管CT

前瞻性心电门控高螺距光子计数CT血管成像:TAVR规划中主动脉瓣环测量准确性的评估

Prospective ECG-gated High-Pitch Photon-Counting CT Angiography: Evaluation of measurement accuracy for aortic annulus sizing in TAVR planning.
PubMed 文献 · Eur J Radiol · 2024-07-06

本研究纳入30例患者行心脏螺旋CT与前瞻性心电门控高螺距CTA,并用倾向性评分匹配另选30例行非心电门控高螺距CTA,评估瓣环测量准确性。结果显示前瞻性心电门控高螺距CTA与心脏螺旋CT各瓣环测量值强相关且无显著差异,辐射剂量显著更低(CTDI 4.52 vs. 24.10 mGy)。非心电门控高螺距CTA在瓣环短轴直径和面积上与心脏螺旋CT存在显著差异。

要点

  • 前瞻性心电门控高螺距CTA在主动脉瓣水平30% R-R采集,90%病例于收缩期成像,非心电门控仅50%(p=0.002)。
  • 前瞻性心电门控高螺距CTA与心脏螺旋CT瓣环直径、周长、面积测量强相关(r≥0.94)且无显著差异(p≥0.09)。
  • 前瞻性心电门控高螺距CTA的CTDI为4.52 mGy,显著低于心脏螺旋CT的24.10 mGy(p<0.001)。

核心结论

  • 基于光子计数探测器CT的前瞻性心电门控高螺距扫描在主动脉瓣水平靶向收缩期采集,可同时显示TAVR入路并准确测量收缩期瓣环尺寸;该方法可能有助于优化方案,在不断增长的年轻低危TAVR患者人群中实现更低辐射剂量。

研究设计与样本

  • 前瞻性研究,30例患者行心脏螺旋CT和前瞻性心电门控(主动脉瓣水平30% R-R)高螺距CTA;另通过倾向性评分匹配识别30例接受无心电同步高螺距CTA的患者;两名研究者测量瓣环直径、周长和面积。

诊断标准与关键数值

  • 前瞻性心电门控高螺距CTA与心脏螺旋CT所有瓣环测量值强相关(r≥0.94),差异无统计学意义(p≥0.09)。
  • 非心电门控高螺距CTA与心脏螺旋CT在瓣环短轴直径和面积上差异有统计学意义(p≤0.03)。
  • 前瞻性心电门控高螺距CTA的CTDI为4.52 mGy,心脏螺旋CT为24.10 mGy(p<0.001)。
  • 前瞻性心电门控高螺距CTA在90%病例于收缩期成像,非心电门控高螺距CTA为50%(p=0.002)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: In planning transcatheter aortic valve replacement (TAVR), retrospective cardiac spiral-CT is recommended to measure aortic annulus with subsequent CT-angiography (CTA) to evaluate access routes. Photon-counting detector (PCD)-CT enables to assess the aortic annulus in desired cardiac phases, using prospective ECG-gated high-pitch CTA. The aim of this study was to evaluate the measurement accuracy of aortic annulus using prospective ECG-gated high-pitch CTA against retrospective spiral-CT reference.

METHOD: Thirty patients underwent cardiac spiral-CT and prospective ECG-gated (30% R-R on aortic valve level) high-pitch CTA. Using propensity score matching, another 30 patients were identified whose CTA was performed using high-pitch mode without ECG-synchronization. Two investigators measured annular diameter, perimeter, and area on cardiac spiral-CT and high-pitch CTA.

RESULTS: The aortic valve was imaged in systole in 90 % of prospective ECG-gated CTA cases but only 50 % of non-ECG-gated CTA cases (p = 0.002). There was a strong correlation (r ≥ 0.94) without significant differences (p ≥ 0.09) between cardiac spiral-CT and prospective ECG-gated high-pitch CTA for all annulus measurements. In contrast, significant differences were found in annular short-axis diameter and area between cardiac spiral-CT and non-ECG-gated high-pitch CTA (p ≤ 0.03). Furthermore, prospective ECG-gated high-pitch CTA showed significantly reduced radiation exposure compared with cardiac spiral-CT (CTDI 4.52 vs. 24.10 mGy; p < 0.001).

CONCLUSION: PCD-CT-based prospective ECG-gated high-pitch scans with targeted systolic acquisition at the level of the aortic valve can simultaneously visualize TAVR access routes and accurately measure systolic annulus size. This approach could aid in optimizing protocols to achieve lower radiation doses in the growing population of younger, low-risk TAVR patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yang Y, Richter R, Halfmann MC, et al. Prospective ECG-gated High-Pitch Photon-Counting CT Angiography: Evaluation of measurement accuracy for aortic annulus sizing in TAVR planning. Eur J Radiol. 2024. PMID: 38996738. doi:10.1016/j.ejrad.2024.111604

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。