文献速递心血管胸部CT

光子计数探测器CT虚拟平扫成像钙化评分中提高对小而低密度斑块的检测

Improved Detection of Small and Low-Density Plaques in Virtual Noncontrast Imaging-based Calcium Scoring at Photon-Counting Detector CT.
PubMed 文献 · Radiol Cardiothorac Imaging · 2024-01-01

这项前瞻性研究在体模和63例受试者中评估斑块大小和密度对基于虚拟平扫(VNC)的冠状动脉钙化评分(CACS)的影响,并与真平扫(TNC)比较。标准VNC重建对小斑块不可检测,对低密度斑块相关性差;采用安全网重建(55 keV、QIR 2、110 HU阈值)使体内细微斑块检出率提高89%(56处中检出50处),并改善与TNC评分的一致性和相关性。

要点

  • 标准VNC重建对1 mm小斑块不可检测,对低密度斑块相关性仅ICC 0.20-0.48。
  • 安全网重建(55 keV、QIR 2、110 HU阈值)使体内细微斑块检出增加89%(56处中检出50处)。
  • 对钙化评分低而标准VNC可能漏诊的患者,安全网重建可能特别有用。

核心结论

  • 与基于TNC的钙化评分相比,基于VNC的钙化评分对小而低密度斑块有限,但使用安全网重建可改善,可能对低钙化评分且可能因假阴性结果而被治疗的患者特别有用。

研究设计与样本

  • 前瞻性研究,体模含直径5、3、1 mm及密度800、400、200 mg/cm3的钙化,体内队列63例(57.8岁±15.5,男37例[59%]、女26例[41%]),行TNC和增强心脏光子计数探测器CT(2021年7月-2022年3月),以70 keV、QIR关闭的TNC为参考标准。

诊断标准与关键数值

  • 标准设置:3.0 mm层厚、Qr36核、130 HU阈值;小斑块评估另用1.0 mm层厚、Qr44核、120或110 HU阈值;安全网重建参数为55 keV、QIR 2、110 HU阈值。

临床应用与阅片要点

  • 标准VNC重建对大中尺寸及高中密度斑块一致性较高(体外ICC≥0.90,r>0.9),对低密度斑块一致性低(ICC=0.20-0.48,r=0.5-0.6);安全网重建可提高细微斑块检出(体内增加89%,56处中检出50处)并改善与TNC的相关性(ICC=0.51-0.61,r=0.6)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Fink N, Emrich T, Schoepf UJ, et al. Improved Detection of Small and Low-Density Plaques in Virtual Noncontrast Imaging-based Calcium Scoring at Photon-Counting Detector CT. Radiol Cardiothorac Imaging. 2024. PMID: 39023373. doi:10.1148/ryct.230328

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。