心脏T2*BOLD与定量血流分数在多支冠状动脉病变患者狭窄冠状动脉诊断中的关联
本研究纳入50例多支冠状动脉病变患者和21例健康对照,行冠状动脉造影联合QFR测量及心脏磁共振检查,以QFR≤0.80为血流动力学梗阻标准。T2*BOLD与QFR在诊断伴血流动力学改变的狭窄冠状动脉方面相关性良好,且T2*BOLD在无负荷状态下分析心肌缺血优于半定量灌注成像。
要点
- T2*BOLD诊断LAD狭窄(QFR≤0.8)的AUC为0.97,RCA为0.91,LCX为0.69。
- T2*BOLD在无负荷状态下分析心肌缺血优于半定量灌注成像。
- T2*BOLD与QFR在诊断伴血流动力学改变的狭窄冠状动脉方面相关性良好。
核心结论
- T2*BOLD与QFR在诊断稳定多支冠状动脉病变患者伴血流动力学改变的狭窄冠状动脉方面相关性良好,T2*BOLD在无负荷状态下分析心肌缺血优于半定量灌注成像。
研究设计与样本
- 研究纳入50例至少1处显著冠状动脉狭窄(直径狭窄>50%)的多支冠状动脉病变患者和21例健康对照,行冠状动脉造影联合QFR测量及心脏磁共振检查,以QFR≤0.80为血流动力学梗阻标准。
关键影像表现/征象
- 狭窄冠状动脉(QFR≤0.8)与正常血管之间,T2*BOLD诊断LAD、LCX和RCA的AUC分别为0.97、0.69和0.91,PI的AUC分别为0.89、0.77和0.90(除LAD外,其余p>0.05)。
- 狭窄冠状动脉(QFR>0.8)与正常血管之间,T2*BOLD诊断LAD、LCX和RCA的AUC分别为0.86、0.72和0.85,PI的AUC分别为0.93、0.86和0.88(p>0.05)。
- 冠状动脉狭窄(QFR≤0.8与>0.8)之间,T2*BOLD诊断LAD、LCX和RCA的AUC分别为0.96、0.74和0.91,但LAD、LCX和RCA的平均PI在两者间无显著差异。
诊断标准与关键数值
- QFR≤0.80视为存在血流动力学梗阻。
- T2*BOLD诊断狭窄冠状动脉(QFR≤0.8)与正常血管的AUC:LAD 0.97、LCX 0.69、RCA 0.91;PI的AUC:LAD 0.89、LCX 0.77、RCA 0.90(除LAD外,其余p>0.05)。
- T2*BOLD诊断狭窄冠状动脉(QFR>0.8)与正常血管的AUC:LAD 0.86、LCX 0.72、RCA 0.85;PI的AUC:LAD 0.93、LCX 0.86、RCA 0.88(p>0.05)。
- T2*BOLD诊断冠状动脉狭窄(QFR≤0.8与>0.8)的AUC:LAD 0.96、LCX 0.74、RCA 0.91,而LAD、LCX和RCA的平均PI在两者间无显著差异。
临床应用与阅片要点
- T2*BOLD与QFR在诊断伴血流动力学改变的狭窄冠状动脉方面相关性良好。
- T2*BOLD在无负荷状态下分析心肌缺血优于半定量灌注成像。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: T2*BOLD is based on myocardial deoxyhemoglobin content to reflect the state of myocardial oxygenation. Quantitative flow ratio is a tool for assessing coronary blood flow based on invasive coronary angiography.
PURPOSE: This study aimed to evaluate the correlation between T2*BOLD and QFR in the diagnosis of stenotic coronary arteries in patients with multi-vessel coronary artery disease.
METHODS: Fifty patients with MVCAD with at least 1 significant coronary artery stenosis (diameter stenosis > 50%) and 21 healthy control subjects underwent coronary angiography combined with QFR measurements and cardiovascular magnetic resonance (CMR). QFR ≤ 0.80 was considered to indicate the presence of hemodynamic obstruction.
RESULTS: Totally 60 (54%) obstructive vessels had hemodynamic change. Between stenotic coronary arteries (QFR ≤ 0.8) and normal vessels, T2*BOLD showed AUCs of 0.97, 0.69, and 0.91 for left anterior descending (LAD), left circumflex (LCX) and right coronary (RCA) arteries and PI displayed AUCs of 0.89, 0.77 and 0.90 (all p > 0.05, except for LAD). The AUCs of T2*BOLD between stenotic coronary arteries (QFR > 0.8) and normal vessels were 0.86, 0.72, and 0.85 for LAD, LCX and RCA; while, PI showed AUCs of 0.93, 0.86, and 0.88, respectively (p > 0.05). Moreover, T2*BOLD displayed AUCs of 0.96, 0.74, and 0.91 for coronary arteries as before between coronary arteries with stenosis (QFR ≤ 0.8 and > 0.8), but the mean PI of LAD, LCX and RCA showed no significant differences between them.
CONCLUSION: T2* BOLD and QFR have good correlation in diagnosing stenotic coronary arteries with hemodynamic changes in patients with stable multi-vessel CAD. T2* BOLD is superior to semi-quantitative perfusion imaging in analyzing myocardial ischemia without stress.
引用
- Zhao L, Chen BH, Tang H, et al. The association between cardiac T2*BOLD and quantitative flow ratio (QFR) in the diagnosis of stenotic coronary arteries in patients with multi-vessel coronary artery disease. Radiol Med. 2024. PMID: 38997567. doi:10.1007/s11547-024-01847-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。