基于块的高阶奇异值分解去噪改进扩散加权超极化129Xe肺MRI
研究在模拟图像、气体体模及120例受试者(34例对照、39例囊性纤维化、27例淋巴管肌瘤病、20例哮喘)的扩散加权129Xe MRI中应用GLHOSVD去噪,去噪后图像SNR提高逾2倍(p < 0.001),ADC与DDC均值不变(p > 0.05)但标准差显著降低(p < 0.001),使高扩散区域肺空气腔大小得以量化。
要点
- GLHOSVD去噪使扩散加权129Xe图像SNR提高逾2倍(p < 0.001)。
- 去噪后ADC与DDC均值不变(p > 0.05),但标准差显著降低(p < 0.001)。
- 去噪使原本因SNR过低无法测量的高扩散区域肺空气腔大小得以量化。
核心结论
- GLHOSVD去噪应用于扩散加权129Xe图像可改善图像质量,并使原本因SNR过低无法测量的高扩散区域肺空气腔大小得以量化,从而为疾病病理提供信息。
研究设计与样本
- 研究在已知扩散系数的模拟图像和气体体模中验证GLHOSVD去噪并优化参数,随后应用于120例受试者(34例对照、39例囊性纤维化、27例淋巴管肌瘤病、20例哮喘)的扩散加权129Xe MRI数据,采用Wilcoxon符号秩检验比较去噪前后图像SNR、ADC和DDC。
诊断标准与关键数值
- 扩散加权成像常用表观扩散系数(ADC)映射正常衰老和肺部疾病所致肺泡空气腔大小的变化。
- 去噪后图像SNR提高逾2倍(p < 0.001),ADC与DDC均值不变(p > 0.05),ADC与DDC标准差显著降低(p < 0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Hyperpolarized xenon (129Xe) MRI is a noninvasive method to assess pulmonary structure and function. To measure lung microstructure, diffusion-weighted imaging-commonly the apparent diffusion coefficient (ADC)-can be employed to map changes in alveolar-airspace size resulting from normal aging and pulmonary disease. However, low signal-to-noise ratio (SNR) decreases ADC measurement certainty, and biases ADC to spuriously low values. Further, these challenges are most severe in regions of the lung where alveolar simplification or emphysematous remodeling generate abnormally high ADCs. Here, we apply Global Local Higher Order Singular Value Decomposition (GLHOSVD) denoising to enhance image SNR, thereby reducing uncertainty and bias in diffusion measurements.
MATERIALS AND METHODS: GLHOSVD denoising was employed in simulated images and gas phantoms with known diffusion coefficients to validate its effectiveness and optimize parameters for analysis of diffusion-weighted 129Xe MRI. GLHOSVD was applied to data from 120 subjects (34 control, 39 cystic fibrosis (CF), 27 lymphangioleiomyomatosis (LAM), and 20 asthma). Image SNR, ADC, and distributed diffusivity coefficient (DDC) were compared before and after denoising using Wilcoxon signed-rank analysis for all images.
RESULTS: Denoising significantly increased SNR in simulated, phantom, and in-vivo images, showing a greater than 2-fold increase (p < 0.001) across diffusion-weighted images. Although mean ADC and DDC remained unchanged (p > 0.05), ADC and DDC standard deviation decreased significantly in denoised images (p < 0.001).
CONCLUSION: When applied to diffusion-weighted 129Xe images, GLHOSVD improved image quality and allowed airspace size to be quantified in high-diffusion regions of the lungs that were previously inaccessible to measurement due to prohibitively low SNR, thus providing insights into disease pathology.
引用
- Soderlund SA, Bdaiwi AS, Plummer JW, et al. Improved Diffusion-Weighted Hyperpolarized 129Xe Lung MRI with Patch-Based Higher-Order, Singular Value Decomposition Denoising. Acad Radiol. 2024. PMID: 38960843. doi:10.1016/j.acra.2024.06.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。