光子计数探测器CT肺灌注成像的图像质量:与双源双能量CT的比较

Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT.
PubMed 文献 · Eur Radiol · 2024-07-05

本研究连续纳入71例接受光子计数探测器CT(PCD-CT)扫描的患者,与配对的双源双能量CT(DECT)扫描人群比较肺灌注图像质量。结果显示PCD-CT数据采集时间更短、剂量长度乘积更低,灌注图像主观噪声更少、叶间裂显示更清晰、心脏运动伪影更轻,形态学图像质量相似。结论认为PCD-CT在更低辐射剂量下提供相似形态学图像质量和更优的灌注成像。

要点

  • PCD-CT灌注图像中叶间裂锐利显示的比例为84.5%(60例),高于DECT的26.6%(26例)。
  • PCD-CT组97.2%(69例)的检查心脏运动伪影评为轻度,DECT组73.2%(52例)为中度。
  • PCD-CT数据采集时间0.93±0.1秒,短于DECT的3.98±0.35秒,剂量长度乘积172.6±55.14 mGy·cm低于DECT的339.4±75.64 mGy·cm。

核心结论

  • PCD-CT采集在更低辐射剂量下提供与双源双能量CT相似的形态学图像质量和更优的灌注成像。

研究设计与样本

  • 连续纳入71例PCD-CT扫描患者,与配对的双源双能量CT扫描人群比较;PCD-CT采用单源采集,准直144×0.4 mm,螺距1.5;DECT采用第三代双源CT,准直64×0.6×2 mm,螺距0.55;两组注射方案相似,通过高、低能虚拟单能图像减影重建灌注图像。

关键影像表现/征象

  • 灌注图像上,PCD-CT组主观图像噪声低于DECT组(p=0.049),平均衰减水平无差异(p=0.05)。
  • 叶间裂清晰显示的比例PCD-CT组为84.5%(60例),DECT组为26.6%(26例),两组评分分布差异有统计学意义(p<0.0001)。
  • 心脏运动伪影评级两组差异有统计学意义(p<0.0001),PCD-CT组以轻度伪影为主(97.2%,69例),DECT组以中度伪影为主(73.2%,52例)。
  • 纵隔图像上,PCD-CT组客观噪声水平更高(p<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT).

METHODS: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.55; (b) for PCD-CT (Group 2): collimation: 144 × 0.4 mm; pitch: 1.5; single-source acquisition. The injection protocol was similar in both groups with the reconstruction of perfusion images by subtraction of high- and low-energy virtual monoenergetic images.

RESULTS: Compared to Group 1, Group 2 examinations showed: (a) a shorter duration of data acquisition (0.93 ± 0.1 s vs 3.98 ± 0.35 s; p < 0.0001); (b) a significantly lower dose-length-product (172.6 ± 55.14 vs 339.4 ± 75.64 mGy·cm; p < 0.0001); and (c) a higher level of objective noise (p < 0.0001) on mediastinal images. On perfusion images: (a) the mean level of attenuation did not differ (p = 0.05) with less subjective image noise in Group 2 (p = 0.049); (b) the distribution of scores of fissure visualization differed between the 2 groups (p < 0.0001) with a higher proportion of fissures sharply delineated in Group 2 (n = 60; 84.5% vs n = 26; 26.6%); (c) the rating of cardiac motion artifacts differed between the 2 groups (p < 0.0001) with a predominance of examinations rated with mild artifacts in Group 2 (n = 69; 97.2%) while the most Group 1 examinations showed moderate artifacts (n = 52; 73.2%).

CONCLUSION: PCD-CT acquisitions provided similar morphologic image quality and superior perfusion imaging at lower radiation doses.

CLINICAL RELEVANCE STATEMENT: The improvement in the overall quality of perfusion images at lower radiation doses opens the door for wider applications of lung perfusion imaging in clinical practice.

KEY POINTS: The speed of data acquisition with PCD-CT accounts for mild motion artifacts. Sharply delineated fissures are depicted on PCD-CT perfusion images. High-quality perfusion imaging was obtained with a 52% dose reduction.

来源:Eur Radiol,查看原文。版权归原作者所有。