文献速递神经外周血管CTMR

提升动脉瘤性蛛网膜下腔出血后迟发性脑缺血的诊断精度:灌注成像上的血管痉挛指数评分在检测血管痉挛中的潜力

Advancing diagnostic precision of delayed cerebral ischemia in aneurysmal subarachnoid hemorrhage: The potential for a vasospasm index score on perfusion imaging to detect vasospasm.
PubMed 文献 · Eur J Radiol · 2024-06-27

本研究为病例对照研究,纳入54例动脉瘤性蛛网膜下腔出血患者和119例无aSAH对照,评估MR或CT灌注参数对血管痉挛的诊断价值。血管痉挛指数评分(Tmax6/Tmax4)联合CBV≤48%预测血管痉挛的AUC为0.85(95%CI 0.78-0.91),敏感度63%、特异度95%。

要点

  • 血管痉挛指数评分定义为Tmax>6s脑体积与Tmax>4s脑体积的比值。
  • 血管痉挛指数评分联合CBV≤48%预测血管痉挛的AUC为0.85(95%CI 0.78-0.91),敏感度63%、特异度95%。
  • 该联合指标对脑血管造影证实的血管痉挛具有较强预测价值。

核心结论

  • 灌注成像上的血管痉挛指数评分联合CBV≤48%可可靠识别血管痉挛作为迟发性脑缺血的原因。

研究设计与样本

  • 病例对照研究;纳入54例动脉瘤性蛛网膜下腔出血患者(病例)和119例无aSAH对照(对照);病例在数字减影血管造影前≤24小时接受MR灌注或CT灌注成像;对照接受CT灌注成像;测量不同阈值下的定量灌注参数(Tmax 4-6-8-10秒延迟、脑血流量、脑血容量)并进行比较。

诊断标准与关键数值

  • 血管痉挛指数评分计算为Tmax延迟>6秒的脑体积除以Tmax>4秒的脑体积;血管痉挛指数评分联合CBV≤48%预测脑血管造影上的血管痉挛,AUC为0.85(95%CI 0.78-0.91),敏感度63%,特异度95%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The occurrence of delayed cerebral ischemia and vasospasm following aneurysmal subarachnoid hemorrhage (aSAH) results in high morbidity and mortality, but the diagnosis remains challenging. This study aimed to identify neuroimaging perfusion parameters indicative of delayed cerebral ischemia in patients with suspected vasospasm.

METHODS: This is a case-control study. Cases were adult aSAH patients who underwent magnetic resonance perfusion or computed tomography perfusion (CTP) imaging ≤ 24 h before digital subtraction angiography performed for vasospasm diagnosis and treatment. Controls were patients without aSAH who underwent CTP. Quantitative perfusion parameters at different thresholds, including Tmax 4-6-8-10 s delay, cerebral blood flow and cerebral blood volume were measured and compared between cases and controls. The Vasospasm Index Score was calculated as the ratio of brain volume with time-to-max (Tmax) delay > 6 s over volume with Tmax > 4 s.

RESULTS: 54 patients with aSAH and 119 controls without aSAH were included. Perfusion parameters with the strongest prediction of vasospasm on cerebral angiography were the combination of the Vasospasm Index Score (Tmax6/Tmax4) + CBV ≤ 48 % (area under the curve value of 0.85 [95 % CI 0.78-0.91]) with a sensitivity of 63 % and specificity of 95 %.

CONCLUSION: The Vasospasm Index Score in combination with CBV ≤ 48 % on cerebral perfusion imaging reliably identified vasospasm as the cause of DCI on perfusion imaging.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Bombardieri AM, Seners P, Wouters A, et al. Advancing diagnostic precision of delayed cerebral ischemia in aneurysmal subarachnoid hemorrhage: The potential for a vasospasm index score on perfusion imaging to detect vasospasm. Eur J Radiol. 2024. PMID: 38981177. doi:10.1016/j.ejrad.2024.111578

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。