基于双能CT的影像组学模型可判断大脑中动脉闭塞卒中患者的血栓来源
本研究回顾性纳入大脑中动脉闭塞患者,基于平扫CT、双能CT血管成像重建的70 keV虚拟单能图像和碘叠加图提取影像组学特征,构建预测心源性栓塞的逻辑回归模型。NCCT+IOM联合模型表现最佳,训练集AUC为0.95,测试集AUC为0.92,结合临床信息后模型性能未显著提升。
要点
- 基于平扫CT与碘叠加图的影像组学模型对心源性栓塞的预测AUC在训练集为0.95、测试集为0.92。
- NCCT+IOM模型在训练集AUC显著高于NCCT、CTA、IOM及NCCT+CTA模型(P<0.05)。
- 联合临床信息后模型性能与NCCT+IOM模型无统计学显著差异(P>0.05)。
核心结论
- 基于平扫CT和碘叠加图构建的影像组学模型可有效判断卒中血栓来源,且不依赖临床信息。
研究设计与样本
- 回顾性纳入大脑中动脉闭塞患者,行平扫CT和双能CT血管成像,重建70 keV虚拟单能图像(模拟常规120kVp CTA图像)和碘叠加图,构建5个预测心源性栓塞的逻辑回归影像组学模型。
诊断标准与关键数值
- NCCT+IOM模型训练集AUC=0.95,显著高于NCCT模型(AUC=0.88)、CTA模型(AUC=0.78)、IOM模型(AUC=0.90)和NCCT+CTA模型(AUC=0.87),P<0.05;测试集AUC=0.92,显著高于CTA模型(AUC=0.71),P<0.05。
临床应用与阅片要点
- 吸烟和NIHSS评分是心源性栓塞的独立预测因子(P<0.05);联合模型与NCCT+IOM模型AUC无统计学显著差异(训练集0.96 vs. 0.95,测试集0.94 vs. 0.92,均P>0.05)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To develop thrombus radiomics models based on dual-energy CT (DECT) for predicting etiologic cause of stroke.
METHODS: We retrospectively enrolled patients with occlusion of the middle cerebral artery who underwent computed tomography (NCCT) and DECT angiography (DECTA). 70 keV virtual monoenergetic images (simulate conventional 120kVp CTA images) and iodine overlay maps (IOM) were reconstructed for analysis. Five logistic regression radiomics models for predicting cardioembolism (CE) were built based on the features extracted from NCCT, CTA and IOM images. From these, the best one was selected to integrate with clinical information for further construction of the combined model. The performance of the different models was evaluated and compared using ROC curve analysis, clinical decision curves (DCA), calibration curves and Delong test.
RESULTS: Among all the radiomic models, model NCCT+IOM performed the best, with AUC = 0.95 significantly higher than model NCCT, model CTA, model IOM and model NCCT+CTA in the training set (AUC = 0.88, 0.78, 0.90,0.87, respectively, P < 0.05), and AUC = 0.92 in the testing set, significantly higher than model CTA (AUC = 0.71, P < 0.05). Smoking and NIHSS score were independent predictors of CE (P < 0.05). The combined model performed similarly to the model NCCT+IOM, with no statistically significant difference in AUC either in the training or test sets. (0.96 vs. 0.95; 0.94 vs. 0.92, both P > 0.05).
CONCLUSION: Radiomics models constructed based on NCCT and IOM images can effectively determine the source of thrombus in stroke without relying on clinical information.
引用
- Ma Y, Dai Y, Zhao Y, et al. Radiomics model based on dual-energy CT can determine the source of thrombus in strokes with middle cerebral artery occlusion. Neuroradiology. 2024. PMID: 38985319. doi:10.1007/s00234-024-03422-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。