评估CT灌注中的对比剂团注峰值位置:大型队列中年龄依赖性存在但变异仍大

Assessing bolus peak position in CT perfusion: High variance persisting despite age-dependency in a large cohort.
PubMed 文献 · Eur J Radiol · 2024-07-02

研究纳入2624例CT灌注扫描(女性52%,平均年龄72.2±14.4岁),其中卒中1636例,分析动脉输入函数和缺血半暗带的团注峰值位置分布及其与年龄的关联。结果显示年龄与动脉输入函数及半暗带峰值位置均显著相关(ρ=0.334、0.305、0.246,均p<0.001),但各年龄段峰值位置范围仍大,提示非均匀采样方案可能无法在所有病例中最佳捕获团注。

要点

  • 年龄与动脉输入函数及半暗带团注峰值位置显著相关,老年患者峰值更晚。
  • 尽管存在年龄依赖性,各年龄段动脉输入函数和半暗带峰值位置范围仍大。
  • 非均匀采样方案可能无法在所有病例中最佳捕获团注。

核心结论

  • 研究显示对比剂团注到达在健康及缺血组织中均有强年龄依赖性,但峰值位置变异大,使非均匀采样方案可能无法在所有病例中最佳捕获团注。

研究设计与样本

  • 研究纳入2624例CT灌注扫描(女性52%,平均年龄72.2±14.4岁),其中卒中1636例,从动脉输入函数和半暗带的衰减时间曲线计算团注峰值位置并分析其分布及与年龄的关联。

诊断标准与关键数值

  • 全队列中年龄与动脉输入函数团注峰值位置显著相关(ρ=0.334;p<0.001)。
  • 卒中患者中年龄与动脉输入函数峰值位置相关(ρ=0.305;p<0.001)。
  • 卒中患者中年龄与半暗带峰值位置相关(ρ=0.246;p<0.001)。
  • 老年患者动脉输入函数和半暗带团注峰值均显著更晚(均p<0.001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: CT perfusion (CTP) is a valuable tool in suspected acute ischemic stroke. A substantial variability of the delay between contrast injection and bolus arrival in the brain is conceivable. We investigated the distribution of the peak positions of the concentration time curves measured in an artery (arterial input function, AIF) and - in cases with ischemia - also measured in the penumbra.

METHODS: We report on 2624 perfusion scans (52 % female, mean age 72.2 ± 14.4 years) with stroke present in 1636 cases. From the attenuation time curves of the AIF and the penumbra, we calculated the respective bolus peak positions and investigated the distribution of the peak positions. Further, we analyzed the bolus peak positions for associations with age.

RESULTS: The bolus peaked significantly later in older patients, both in the AIF and in the penumbra (all p < 0.001). In the whole cohort, we found a significant association of age with the bolus peak position of the AIF (ρ = 0.334; p < 0.001). In patients with stroke, age was also associated to the peak position of the AIF (ρ = 0.305; p < 0.001), and the penumbra (ρ = 0.246, p < 0.001). However, a substantial range of peak positions of the AIF and penumbra was noted across all age ranges.

CONCLUSIONS: This study revealed a strong age-dependency of the contrast bolus arrival in both healthy and ischemic tissue. This variability makes non-uniform sampling schemes, which have been suggested to reduce radiation dose, problematic, as they might not always optimally capture the bolus in all cases.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Stein T, Kellner E, Mueller-Peltzer K, et al. Assessing bolus peak position in CT perfusion: High variance persisting despite age-dependency in a large cohort. Eur J Radiol. 2024. PMID: 38970994. doi:10.1016/j.ejrad.2024.111595

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。