文献速递神经技术与安全US

蛛网膜容积尺寸比:一种用于颅内压评估的优越视神经鞘指数

Dimensions of Arachnoid Bulk Ratio: A Superior Optic Nerve Sheath Index for Intracranial Pressure.
PubMed 文献 · Radiology · 2024-01-01

这项前瞻性队列研究纳入30例疑似颅内压升高患者,在侵入性测压前用超声测量蛛网膜容积尺寸比(DAB比)与视神经鞘直径(ONSD)。DAB比与颅内压相关性更强(rs=0.87 vs 0.61),预测颅内压升高的AUC更高(0.98 vs 0.86,P=.047),敏感度100% vs 92%、特异度94% vs 83%。

要点

  • DAB比预测颅内压升高的AUC为0.98,高于ONSD的0.86(P=.047)。
  • DAB比最佳阈值为0.5,敏感度100%、特异度94%。
  • DAB比与颅内压相关性(rs=0.87)强于ONSD(rs=0.61)。

核心结论

  • 基于脑脊液间隙相对解剖的影像比值可预测颅内压,诊断准确性高于ONSD且与颅内压值强相关,提示其可能作为临床神经影像标志物。

研究设计与样本

  • 前瞻性队列研究,2022年4月至2023年12月纳入30例疑似颅内压升高患者(平均年龄39岁±14,24例女性),在侵入性颅内压测量前行视神经超声测量DAB比与ONSD,以侵入性测压为参考标准。

关键影像表现/征象

  • 颅内压升高者的DAB比和ONSD均显著更大,分别大38%(0.16/0.42)和14%(0.82/6.04 mm),P<.001。

诊断标准与关键数值

  • DAB比预测颅内压升高的最佳阈值为0.5,敏感度100%、特异度94%。
  • ONSD预测颅内压升高的最佳阈值为6.5 mm,敏感度92%、特异度83%。
  • DAB比预测颅内压升高的AUC为0.98(95%CI:0.95,1.00),ONSD为0.86(95%CI:0.71,0.95),P=.047。
  • DAB比与颅内压的相关系数rs=0.87(P<.001),ONSD为rs=0.61(P<.001)。

临床应用与阅片要点

  • 作者认为DAB比可能作为临床环境中的神经影像标志物用于预测颅内压升高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Discrepancies in the literature regarding optimal optic nerve sheath diameter (ONSD) cutoffs for intracranial pressure (ICP) necessitate alternative neuroimaging parameters to improve clinical management. Purpose To evaluate the diagnostic accuracy of the dimensions of the perineural subarachnoid space to the optic nerve sheath ratio, measured using US, in predicting increased ICP. Materials and Methods In a prospective cohort study from April 2022 to December 2023, patients with suspected increased ICP underwent optic nerve US to determine the dimensions of arachnoid bulk (DAB) ratio and ONSD before invasive ICP measurement. Correlation between the parameters and ICP, as well as diagnostic accuracy, was assessed using area under the receiver operating characteristic curve (AUC) analysis. Results A total of 30 participants were included (mean age, 39 years ± 14 [SD]; 24 female). The DAB ratio and ONSD were significantly larger in participants with increased ICP (38% [0.16 of 0.42] and 14% [0.82 of 6.04 mm], respectively; P < .001). The DAB ratio showed a stronger correlation with ICP than ONSD (rs = 0.87 [P < .001] vs rs = 0.61 [P < .001]). The DAB ratio and ONSD optimal cutoffs for increased ICP were 0.5 and 6.5 mm, respectively, and the ratio had higher sensitivity (100% vs 92%) and specificity (94% vs 83%) compared with ONSD. Moreover, the DAB ratio better predicted increased ICP than ONSD, with a higher AUC (0.98 [95% CI: 0.95, 1.00] vs 0.86 [95% CI: 0.71, 0.95], P = .047). Conclusion An imaging ratio was proposed to predict ICP based on the relative anatomy of the cerebrospinal fluid space, demonstrating more accurate diagnosis of increased ICP and a strong correlation with ICP values, suggesting its potential utility as a neuroimaging marker in clinical settings. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Shepherd in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Berhanu D, Carneiro I, Antunes AP, et al. Dimensions of Arachnoid Bulk Ratio: A Superior Optic Nerve Sheath Index for Intracranial Pressure. Radiology. 2024. PMID: 38980182. doi:10.1148/radiol.240114

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。