文献速递神经CT

减少颅脑CT静脉碘对比剂用量对图像诊断质量的影响

Impact of reducing iodinated intravenous contrast volume in brain CT on image diagnostic quality.
PubMed 文献 · Eur J Radiol · 2024-07-23

这项前瞻性单中心研究将接受60 ml对比剂的47例患者与年龄性别匹配、接受常规80 cc的55例对照组比较,神经放射科医师用5点评分评估六个结构。80 cc组所有结构强化评分均显著更高,差异-0.241至-0.433(p<0.001),VGC分析证实80 cc组脑实质强化更明显,结论为从80 cc减至60 cc导致图像质量和诊断准确性显著下降。

要点

  • 80 cc组六个脑结构的强化评分均显著高于60 cc组,差异范围-0.241至-0.433(p<0.001)。
  • VGC分析证实80 cc组脑实质强化显著大于60 cc组。
  • 作者结论认为对比剂从80 cc减至60 cc导致图像质量和诊断准确性显著下降。

核心结论

  • 颅脑CT静脉碘对比剂从80 cc减至60 cc导致图像质量和诊断准确性统计学显著下降。

研究设计与样本

  • 前瞻性研究,单中心三级医院,60 cc组47例,80 cc对照组55例(年龄性别匹配),神经放射科医师用5点评分六个域评估,ICC=0.873,并行VGC分析。

诊断标准与关键数值

  • 5点评分Likert量表评估六个结构的强化,组间差异-0.241至-0.433(p<0.001);ICC=0.873提示评分者间信度高。

局限性

  • 原文结论指出需要更大 cohort 的进一步研究来确认这些发现并评估这些差异的临床影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate whether reducing the volume of intravenous iodinated contrast material injected during brain computed tomography (CT) provides reliable and accurate imaging without compromising diagnostic accuracy.

METHODS: This prospective study enrolled patients undergoing enhanced brain CT at a single tertiary hospital. Subjects who agreed to participate received a reduced dose of 60 ml contrast. The images were compared to an age and gender-matched control group who received the conventional 80 cc dose. Neuroradiologists assessed image quality and interpretation using a 5-point Likert scale with six specific domains. Based on ICC, inter-rater reliability was high at 0.873. Multiple linear regression predicted overall diagnostic accuracy based on contrast dose, age, and gender. Visual Grading Characteristics (VGC) analysis was also performed to quantify regional brain enhancement differences between the two contrast groups.

RESULTS: The study included 47 patients in the 60 cc group and 55 in the 80 cc control group. The results showed the 80 cc group had significantly higher enhancement ratings compared to 60 cc for all six structures assessed. The differences between groups ranged from -0.241 to -0.433 (p < 0.001) on the 5-point scale.The VGC analysis confirmed significantly greater brain parenchymal enhancement in the 80 cc group compared to the 60 cc group.

CONCLUSION: The findings indicate that reducing the intravenous iodinated contrast material volume during brain CT from 80 cc to 60 cc leads to a statistically significant reduction in image quality and diagnostic accuracy. Further research with larger cohorts is needed to confirm these findings and assess the clinical impact of these differences.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Merhav G, Yahav-Dovrat A, Klein E, et al. Impact of reducing iodinated intravenous contrast volume in brain CT on image diagnostic quality. Eur J Radiol. 2024. PMID: 39047589. doi:10.1016/j.ejrad.2024.111635

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。