CT脊髓造影中肾集合系统密度在自发性颅内低压患者脑脊液漏或脑脊液-静脉连接评估中的临床效用
回顾8年间392例CT脊髓造影,纳入295例分为自发性颅内低压(SIH)伴脑脊液漏确认组35例、未确认组77例及非SIH对照组183例。确认漏组肾集合系统平均密度高于未确认组,两SIH组均高于对照组。肾集合系统密度排除脑脊液漏的阴性预测值在SIH组为84%、全队列为96%,全队列优化阈值下敏感度80%、特异度70%。
要点
- CT脊髓造影中肾集合系统密度在确认脑脊液漏的SIH患者中高于未确认者及非SIH对照。
- 肾集合系统密度排除脑脊液漏的阴性预测值在SIH组为84%、全队列为96%。
- 全队列优化阈值下,肾集合系统密度诊断脑脊液漏的敏感度80%、特异度70%。
核心结论
- 考虑肾集合系统密度可能为评估SIH症状而接受CT脊髓造影的患者提供关于脑脊液漏怀疑的可靠附加间接诊断价值。
研究设计与样本
- 回顾性分析8年间全部CT脊髓造影(n=392),纳入295例,分为SIH伴脑脊液漏确认组(n=35)、SIH未确认漏组(n=77)和非SIH对照组(n=183),采用多因素分析校正患者特征和CT脊髓造影技术差异。
诊断标准与关键数值
- 肾集合系统密度排除脑脊液漏的阴性预测值:SIH患者组84%,全队列96%。
- 全队列优化阈值下,肾集合系统密度诊断脑脊液漏的敏感度80%、特异度70%。
临床应用与阅片要点
- 在评估SIH的CT脊髓造影中,可参考肾集合系统密度作为脑脊液漏的间接征象。
- 肾集合系统密度具有较高的阴性预测值,有助于排除脑脊液漏。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Identifying spontaneous CSF leaks can be difficult on CT myelography (CTM) in patients with suspected spontaneous intracranial hypotension (SIH). The current study compared renal collecting system (RCS) density during CTM in patients with suspected SIH relative to non-SIH controls and evaluated the overall utility as an indirect sign of spontaneous CSF leak in patients with SIH.
METHODS: All CTM performed over an 8-year period (n = 392) were retrospectively reviewed and included cases (n = 295) were divided into groups consisting of SIH patients with (n = 35) or without (n = 77) confirmed CSF leak on CTM and non-SIH controls (n = 183). Average and relative average (relative to systemic contrast density) RCS densities were compared with multivariate analysis adjusting for patient characteristics and CTM technical differences.
RESULTS: Average RCS densities were greater for confirmed versus non-confirmed SIH groups and greater for both SIH groups relative to non-SIH controls. Correlations between RCS density and time from injection to CTM were higher within SIH patient groups compared to controls. Measured RCS density had a higher negative predictive value for excluding CSF leak both within the SIH patient groups as well as the overall cohort (84% and 96%, respectively), with optimized thresholds yielding 80% sensitivity and 70% specificity for the presence of leak in the overall cohort.
CONCLUSION: Accounting for RCS density may provide reliable additional indirect diagnostic value about the suspicion of a CSF leak in patients undergoing CTM for evaluation of SIH symptoms.
引用
- Loewenstern J, McMahon P, Wang D, et al. Clinical utility of CT myelography renal collecting system density in the evaluation of spinal CSF leak or CSF-venous connection in patients with spontaneous intracranial hypotension. Neuroradiology. 2024. PMID: 39030336. doi:10.1007/s00234-024-03426-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。