文献速递神经外周血管MR

动脉瘤内高分辨率4D MR血流成像用于颅内动脉瘤不稳定性的血流动力学成像标志物

Intra-Aneurysmal High-Resolution 4D MR Flow Imaging for Hemodynamic Imaging Markers in Intracranial Aneurysm Instability.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-11-07

本研究为横断面研究,对35例患者37个未破裂颅内动脉瘤行3T MRA和7T 4D MRI血流扫描,将5项血流动力学参数与6项3D形态学替代参数做Pearson相关分析。结果显示WSSMAX、WSSMEAN和OSI与动脉瘤不稳定性形态学3D替代参数相关性最强,未来需在纵向队列中评估这些新成像标志物对动脉瘤不稳定性的预测价值。

要点

  • OSI与长轴长度正相关最强(r=0.87,95% CI 0.76-0.93)。
  • WSSMEAN与体积负相关最强(r=-0.70,95% CI -0.83至-0.49)。
  • 速度搏动指数未显示任何有统计学意义的相关性。

核心结论

  • 5项血流动力学参数中,WSSMAX、WSSMEAN和OSI与动脉瘤不稳定性的形态学3D替代参数相关性最强,作者认为未来需在纵向队列中评估这些新成像标志物对动脉瘤不稳定性的预测价值。

研究设计与样本

  • 横断面研究,纳入35例患者共37个未破裂颅内动脉瘤,行3T MRA和7T 4D MRI血流扫描,以Pearson相关(95% CI)分析5项血流动力学参数与6项3D形态学替代参数的关系。

诊断标准与关键数值

  • WSSMAX和WSSMEAN与全部3项尺寸参数负相关,WSSMEAN与体积相关性最强(r=-0.70,95% CI -0.83至-0.49);OSI与长轴长度正相关最强(r=0.87,95% CI 0.76-0.93)。WSSMAX和WSSMEAN与形状指数正相关(分别为r=0.61,95% CI 0.36-0.78和r=0.49,95% CI 0.20-0.70),OSI与形状指数负相关(r=-0.82,95% CI -0.9至-0.68)。WSSMEAN和平均速度与平坦度负相关(分别为r=-0.35,95% CI -0.61至-0.029和r=-0.33,95% CI -0.59至0.007),OSI与平坦度正相关(r=0.54,95% CI 0.26-0.74)。速度搏动指数未显示任何有统计学意义的相关性。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Prediction of aneurysm instability is crucial to guide treatment decisions and to select appropriate patients with unruptured intracranial aneurysms (IAs) for preventive treatment. High-resolution 4D MR flow imaging and 3D quantification of aneurysm morphology could offer insights and new imaging markers for aneurysm instability. In this cross-sectional study, we aim to identify 4D MR flow imaging markers for aneurysm instability by relating hemodynamics in the aneurysm sac to 3D morphologic proxy parameters for aneurysm instability.

MATERIALS AND METHODS: In 35 patients with 37 unruptured IAs, a 3T MRA and a 7T 4D MRI flow scan were performed. Five hemodynamic parameters-peak-systolic wall shear stress (WSSMAX) and time-averaged wall shear stress (WSSMEAN), oscillatory shear index (OSI), mean velocity, and velocity pulsatility index-were correlated to 6 3D morphology proxy parameters of aneurysm instability-major axis length, volume, surface area (all 3 size parameters), flatness, shape index, and curvedness-by Pearson correlation with 95% CI. Scatterplots of hemodynamic parameters that correlated with IA size (major axis length) were created.

RESULTS: WSSMAX and WSSMEAN correlated negatively with all 3 size parameters (strongest for WSSMEAN with volume (r = -0.70, 95% CI -0.83 to -0.49) and OSI positively (strongest with major axis length [r = 0.87, 95% CI 0.76-0.93]). WSSMAX and WSSMEAN correlated positively with shape index (r = 0.61, 95% CI 0.36-0.78 and r = 0.49, 95% CI 0.20-0.70, respectively) and OSI negatively (r = -0.82, 95% CI -0.9 to -0.68). WSSMEAN and mean velocity correlated negatively with flatness (r = -0.35, 95% CI -0.61 to -0.029 and r = -0.33, 95% CI -0.59 to 0.007, respectively) and OSI positively (r = 0.54, 95% CI 0.26-0.74). Velocity pulsatility index did not show any statistically relevant correlation.

CONCLUSIONS: Out of the 5 included hemodynamic parameters, WSSMAX, WSSMEAN, and OSI showed the strongest correlation with morphologic 3D proxy parameters of aneurysm instability. Future studies should assess these promising new imaging marker parameters for predicting aneurysm instability in longitudinal cohorts of patients with IA.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. van Tuijl RJ, den Hertog CS, Timmins KM, et al. Intra-Aneurysmal High-Resolution 4D MR Flow Imaging for Hemodynamic Imaging Markers in Intracranial Aneurysm Instability. AJNR Am J Neuroradiol. 2024. PMID: 38991775. doi:10.3174/ajnr.A8380

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。