文献速递神经外周血管MR

全脑血管构筑成像在活体内识别区域特异性微血管特征

Whole-Brain Vascular Architecture Mapping Identifies Region-Specific Microvascular Profiles In Vivo.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-09-09

本研究为单中心研究,对106例成人单灶稳定低级别胶质瘤患者行3T多频带自旋回波与梯度回波EPI序列全脑血管构筑成像,建立9项参数参考范围并识别区域特异微血管特征。结果显示皮质灰质较白质平均血管口径更大(5.80 vs 4.25,P<.001)、血容量分数更高(20.40 vs 11.05 s⁻¹,P<.001)且以静脉血管为主,丘脑与皮质灰质血管类型指标不同(-2.47 vs -5.41 s⁻²,P<.001),各参数重测信度总体较高。

要点

  • 皮质灰质平均血管口径5.80、血容量分数20.40 s⁻¹,均高于白质的4.25和11.05 s⁻¹(P<.001)。
  • 皮质灰质以静脉血管为主,丘脑与皮质灰质血管类型指标不同(-2.47 vs -5.41 s⁻²,P<.001)。
  • 全脑血管构筑成像参数在成人脑内呈现区域特异性微血管特征,重测信度总体较高。

核心结论

  • 成人全脑血管构筑成像显示区域特异性微血管特征,所获不同解剖与功能区参数参考范围可用于未来脑血管病理的血管构筑成像研究,并可能有助于早期发现神经变性与神经肿瘤学中的微血管改变。

研究设计与样本

  • 单中心研究,纳入106例成人单灶稳定低级别胶质瘤患者(平均年龄39.2岁,SD 12.5;56例女性),采用3T多频带自旋回波与梯度回波EPI序列并行成像。

关键影像表现/征象

  • 基于对比剂团注期间梯度回波(R2*)与自旋回波(R2)弛豫率逐体素绘图生成血管涡旋曲线,提取代表血管类型、血管半径或CBV等9项血管构筑成像参数并计算全脑参数图。

诊断标准与关键数值

  • 皮质灰质平均血管口径5.80(SD 0.59)vs 白质4.25(SD 0.62),P<.001;皮质灰质血容量分数20.40(SD 4.49)s⁻¹ vs 白质11.05(SD 2.44)s⁻¹,P<.001;丘脑血管类型指标均值-2.47(SD 4.02)s⁻² vs 皮质灰质-5.41(SD 2.84)s⁻²,P<.001。

临床应用与阅片要点

  • 血管构筑成像参数参考范围基于标准化脑图谱及个体皮质灰质与白质分割的VOI分析获得,可用于未来脑血管病理的血管构筑成像研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The novel MR imaging technique of vascular architecture mapping allows in vivo characterization of local changes in cerebral microvasculature, but reference ranges for vascular architecture mapping parameters in healthy brain tissue are lacking, limiting its potential applicability as an MR imaging biomarker in clinical practice. We conducted whole-brain vascular architecture mapping in a large cohort to establish vascular architecture mapping parameter references ranges and identify region-specific cortical and subcortical microvascular profiles.

MATERIALS AND METHODS: This was a single-center examination of adult patients with unifocal, stable low-grade gliomas with multiband spin- and gradient-echo EPI sequence at 3T using parallel imaging. Voxelwise plotting of resulting values for gradient-echo (R2*) versus spin-echo (R2) relaxation rates during contrast agent bolus administration generates vessel vortex curves that allow the extraction of vascular architecture mapping parameters representative of, eg, vessel type, vessel radius, or CBV in the underlying voxel. Averaged whole-brain parametric maps were calculated for 9 parameters, and VOI analysis was conducted on the basis of a standardized brain atlas and individual cortical GM and WM segmentation.

RESULTS: Prevalence of vascular risk factors among subjects (n = 106; mean age, 39.2 [SD, 12.5] years; 56 women) was similar to those in the German population. Compared with WM, we found cortical GM to have larger mean vascular calibers (5.80 [SD, 0.59] versus 4.25 [SD, 0.62] P < .001), increased blood volume fraction (20.40 [SD, 4.49] s-1 versus 11.05 [SD, 2.44] s-1; P < .001), and a dominance of venous vessels. Distinct microvascular profiles emerged for cortical GM, where vascular architecture mapping vessel type indicator differed, eg, between the thalamus and cortical GM (mean, -2.47 [SD, 4.02] s-2 versus -5.41 [SD, 2.84] s-2; P < .001). Intraclass correlation coefficient values indicated overall high test-retest reliability for vascular architecture mapping parameter mean values when comparing multiple scans per subject.

CONCLUSIONS: Whole-brain vascular architecture mapping in the adult brain reveals region-specific microvascular profiles. The obtained parameter reference ranges for distinct anatomic and functional brain areas may be used for future vascular architecture mapping studies on cerebrovascular pathologies and might facilitate early discovery of microvascular changes, in, eg, neurodegeneration and neuro-oncology.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Hohmann A, Zhang K, Mooshage CM, et al. Whole-Brain Vascular Architecture Mapping Identifies Region-Specific Microvascular Profiles In Vivo. AJNR Am J Neuroradiol. 2024. PMID: 39054290. doi:10.3174/ajnr.A8344

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。