文献速递神经技术与安全US

无需心电图门控的动态超声定位显微成像

Dynamic Ultrasound Localization Microscopy Without ECG-Gating.
PubMed 文献 · Ultrasound Med Biol · 2024-07-04

本研究提出基于组织多普勒的运动匹配时间配准方法,旨在消除动态超声定位显微成像(DULM)对心电图门控的依赖。该方法在大鼠(n=1)、小鼠(n=3)和猫(n=1)模型中得到验证,运动匹配与心电图门控结果相似,首次无需动物心电图信息即可提取动态速度与密度电影环并估算搏动指数。

要点

  • 运动匹配法利用脑组织周期性运动进行时间配准,无需心电图门控。
  • 在2D小鼠和3D猫模型中获得与心电图门控相似的结果。
  • 首次无需心电图信息提取动态速度与密度电影环并估算搏动指数。

核心结论

  • 结果表明DULM可在无外部门控下进行,使得DULM可用于任何能检测到足够微泡的ULM数据集;运动匹配时间配准是DULM技术的重大进步,通过简化实验复杂性使DULM更易使用。

研究设计与样本

  • 方法学研究:开发基于组织多普勒的运动匹配算法,在大鼠(n=1,心电图门控采集)、小鼠(n=3,2D)和猫(n=1,3D)模型中进行验证。

关键影像表现/征象

  • 运动匹配法基于组织多普勒估计每帧组的组织运动,在颅骨上方皮肤局部最大值处多点识别。
  • 通过各组帧的组织多普勒信号与参考组最大相关值延迟进行时间配准,使每组帧与参考组脑组织运动及心动周期对齐。
  • 微泡速度可被平均以获取随时间变化的流速变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Dynamic Ultrasound Localization Microscopy (DULM) has first been developed for non-invasive Pulsatility measurements in the rodent brain. DULM relies on the localization and tracking of microbubbles (MBs) injected into the bloodstream, to obtain highly resolved velocity and density cine-loops. Previous DULM techniques required ECG-gating, limiting its application to specific datasets, and increasing acquisition time. The objective of this study is to eliminate the need for ECG-gating in DULM experiments by introducing a motion-matching method for time registration.

METHODS: We developed a motion-matching algorithm based on tissue Doppler that leverages the cyclic tissue motion within the brain. Tissue Doppler was estimated for each group of frames in the acquisitions, at multiple locations identified as local maxima in the skin above the skull. Subsequently, each group of frames was time-registered to a reference group by delaying it based on the maximum correlation value between their respective tissue Doppler signals. This synchronization ensured that each group of frames aligned with the brain tissue motion of the reference group, and consequently, with its cardiac cycle. As a result, velocities of MBs could be averaged to retrieve flow velocity variations over time.

RESULTS: Initially validated in ECG-gated acquisitions in a rat model (n = 1), the proposed method was successfully applied in a mice model in 2D (n = 3) and in a feline model in 3D (n = 1). Performing time-registration with the proposed motion-matching method or by using ECG-gating leads to similar results. For the first time, dynamic velocity and density cine-loops were extracted without the need for any information on the animal ECG, and complex dynamic markers such as the Pulsatility index were estimated.

CONCLUSION: Results suggest that DULM can be performed without external gating, enabling the use of DULM on any ULM dataset where enough MBs are detectable. Time registration by motion-matching represents a significant advancement in DULM techniques, making DULM more accessible by simplifying its experimental complexity.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Ghigo N, Ramos-Palacios G, Bourquin C, et al. Dynamic Ultrasound Localization Microscopy Without ECG-Gating. Ultrasound Med Biol. 2024. PMID: 38969526. doi:10.1016/j.ultrasmedbio.2024.05.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。