全自动定位与测量三维盆底超声下提肛肌裂孔尺寸

Fully Automated Localization and Measurement of Levator Hiatus Dimensions Using 3-D Pelvic Floor Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2024-06-05

本研究开发了基于三维盆底超声的AI算法(AI-LH),用于自动定位最小提肛肌裂孔尺寸平面(C平面)并测量最大Valsalva状态下提肛肌裂孔面积(HA)。在240例测试集中,AI-LH与超声医师差异(ASD)及医师间差异(IESD)比较,HA的MAE在ASD为1.44±1.12 mm²,低于IESD的1.63±1.58 mm²;ICC在ASD为0.964,高于IESD的0.949。AI-LH平均耗时2.00±0.22秒,手动测量为59.60±2.63秒(t=18.87,p<0.01)。结论认为AI-LH准确、可靠、稳健,可缩短时间、简化操作,具有良好临床应用价值。

要点

  • AI-LH可在三维盆底超声中自动定位C平面并测量最大Valsalva状态下的提肛肌裂孔面积。
  • AI-LH测量HA的MAE为1.44±1.12 mm²,低于医师间差异的1.63±1.58 mm²。
  • AI-LH平均耗时2.00±0.22秒,显著短于手动测量的59.60±2.63秒(p<0.01)。

核心结论

  • AI-LH在提肛肌裂孔尺寸定位与测量中准确、可靠、稳健,可缩短时间成本、简化操作流程,具有良好临床应用价值。

研究设计与样本

  • 研究为算法开发与验证研究,数据集包含600例容积数据,测试集n=240。
  • AI-LH包含三维平面回归模型和二维分割模型,用于自动定位最小提肛肌裂孔尺寸平面(C平面)并在渲染的提肛肌裂孔图像上测量最大Valsalva状态下的提肛肌裂孔面积(HA),而非在C平面上测量。
  • 对比对象为超声医师差异(ASD)及医师间差异(IESD)。

诊断标准与关键数值

  • C平面定位的ASD角度MAE为4.81±2.47°,中心点距离MAE为1.92±1.54 mm。
  • AI-LH提肛肌裂孔分割的平均Dice系数为0.93。
  • HA测量的MAE:ASD为1.44±1.12 mm²,低于IESD的1.63±1.58 mm²;ICC:ASD为0.964,高于IESD的0.949。
  • 耗时:AI-LH平均2.00±0.22秒,手动测量平均59.60±2.63秒(t=18.87,p<0.01)。

临床应用与阅片要点

  • AI-LH可自动定位C平面并测量最大Valsalva状态下的HA,有望简化三维盆底超声的操作流程并缩短测量时间。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To develop an algorithm for the automated localization and measurement of levator hiatus (LH) dimensions (AI-LH) using 3-D pelvic floor ultrasound.

METHODS: The AI-LH included a 3-D plane regression model and a 2-D segmentation model, which first achieved automated localization of the minimal LH dimension plane (C-plane) and measurement of the hiatal area (HA) on maximum Valsalva on the rendered LH images, but not on the C-plane. The dataset included 600 volumetric data. We compared AI-LH with sonographer difference (ASD) as well as the inter-sonographer differences (IESD) in the testing dataset (n = 240). The assessment encompassed the mean absolute error (MAE) for the angle and center point distance of the C-plane, along with the Dice coefficient, MAE, and intra-class correlation coefficient (ICC) for HA, and included the time consumption.

RESULTS: The MAE of the C-plane of ASD was 4.81 ± 2.47° with 1.92 ± 1.54 mm. AI-LH achieved a mean Dice coefficient of 0.93 for LH segmentation. The MAE on HA of ASD (1.44 ± 1.12 mm²) was lower than that of IESD (1.63 ± 1.58 mm²). The ICC on HA of ASD (0.964) was higher than that of IESD (0.949). The average time costs of AI-LH and manual measurement were 2.00 ± 0.22 s and 59.60 ± 2.63 s (t = 18.87, p < 0.01), respectively.

CONCLUSION: AI-LH is accurate, reliable, and robust in the localization and measurement of LH dimensions, which can shorten the time cost, simplify the operation process, and have good value in clinical applications.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Guo Z, Lu X, Yao J, et al. Fully Automated Localization and Measurement of Levator Hiatus Dimensions Using 3-D Pelvic Floor Ultrasound. Ultrasound Med Biol. 2024. PMID: 38845332. doi:10.1016/j.ultrasmedbio.2024.05.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。