基于多期增强MRI的Delta影像组学分析预测肝细胞癌经皮热消融后早期复发
本研究回顾性纳入164例肝细胞癌患者,基于术前多期增强MRI提取Delta影像组学特征并构建列线图,用于预测经皮热消融后早期复发。列线图在训练集、时间验证集和其他扫描仪验证集的AUC分别为0.893、0.854和0.827,预测性能最佳。结论认为该列线图可无创预测肝细胞癌经皮热消融后早期复发。
要点
- 基于多期增强MRI的Delta影像组学列线图可无创预测肝细胞癌热消融后早期复发
- 列线图在训练集、时间验证集和其他扫描仪验证集的AUC分别为0.893、0.854和0.827
- Child-Pugh B级、高危肿瘤位置及包膜不完整/缺失是早期复发的独立预测因素
核心结论
- 结合Delta影像组学评分与临床-影像学危险因素的列线图可无创预测肝细胞癌经皮热消融后早期复发。
研究设计与样本
- 回顾性纳入164例肝细胞癌患者,分为训练集110例、时间验证集29例和其他扫描仪验证集25例。
- 基于术前多期增强MRI勾画瘤内和/或瘤周感兴趣区,提取各期原始影像组学特征并计算Delta影像组学特征。
- 采用逻辑回归训练影像组学模型,并构建包含最佳影像组学评分和临床-影像学危险因素的融合模型列线图。
诊断标准与关键数值
- Child-Pugh B级、高危肿瘤位置、包膜不完整/缺失为早期复发的独立预测因素。
- 最佳影像组学模型包含12个Delta影像组学特征,训练集、时间验证集和其他扫描仪验证集的AUC分别为0.834、0.795和0.769。
- 列线图在训练集、时间验证集和其他扫描仪验证集的AUC分别为0.893、0.854和0.827。
临床应用与阅片要点
- 术前多期增强MRI的Delta影像组学分析可用于辅助预测肝细胞癌经皮热消融后早期复发。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: It is critical to predict early recurrence (ER) after percutaneous thermal ablation (PTA) for hepatocellular carcinoma (HCC). We aimed to develop and validate a delta-radiomics nomogram based on multi-phase contrast-enhanced magnetic resonance imaging (MRI) to preoperatively predict ER of HCC after PTA.
MATERIALS AND METHODS: We retrospectively enrolled 164 patients with HCC and divided them into training, temporal validation, and other-scanner validation cohorts (n = 110, 29, and 25, respectively). The volumes of interest of the intratumoral and/or peritumoral regions were delineated on preoperative multi-phase MR images. Original radiomics features were extracted from each phase, and delta-radiomics features were calculated. Logistic regression was used to train the corresponding radiomics models. The clinical and radiological characteristics were evaluated and combined to establish a clinical-radiological model. A fusion model comprising the best radiomics scores and clinical-radiological risk factors was constructed and presented as a nomogram. The performance of each model was evaluated and recurrence-free survival (RFS) was assessed.
RESULTS: Child-Pugh grade B, high-risk tumor location, and an incomplete/absent tumor capsule were independent predictors of ER. The optimal radiomics model comprised 12 delta-radiomics features with areas under the curve (AUCs) of 0.834, 0.795, and 0.769 in the training, temporal validation, and other-scanner validation cohorts, respectively. The nomogram showed the best predictive performance with AUCs as 0.893, 0.854, and 0.827 in the three datasets. There was a statistically significant difference in RFS between the risk groups calculated using the delta-radiomics model and nomogram.
CONCLUSIONS: The nomogram combined with the delta-radiomic score and clinical-radiological risk factors could non-invasively predict ER of HCC after PTA.
引用
- Huang W, Pan Y, Wang H, et al. Delta-radiomics Analysis Based on Multi-phase Contrast-enhanced MRI to Predict Early Recurrence in Hepatocellular Carcinoma After Percutaneous Thermal Ablation. Acad Radiol. 2024. PMID: 38902111. doi:10.1016/j.acra.2024.06.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。