文献速递外周血管神经技术与安全US

基于颈动脉超声的高帧率向量血流成像在低度颈动脉狭窄患者中的定量评估

Quantitative evaluation using carotid ultrasonography-based high-frame-rate vector flow imaging in patients with low carotid stenosis.
PubMed 文献 · Br J Radiol · 2024-01-01

单中心横断面研究纳入无颈动脉斑块志愿者与低度颈动脉狭窄患者,用高帧率向量血流成像测量颈总动脉、颈动脉分叉及斑块上游和下游表面的壁面剪切应力、振荡剪切指数和湍流指数;患者颈动脉分叉处壁面剪切应力和湍流指数高于志愿者,有症状患者斑块表面壁面剪切应力更高,斑块下游侧因血流动力学更易破裂。

要点

  • 低度颈动脉狭窄患者颈动脉分叉处壁面剪切应力和湍流指数高于无斑块志愿者。
  • 有症状患者斑块表面壁面剪切应力高于无症状患者。
  • 斑块下游侧因血流动力学更易发生斑块破裂。

核心结论

  • 基于颈动脉超声的高帧率向量血流成像为评估低度狭窄患者血流动力学变化提供可靠的力学生物标志物,可能为监测动脉粥样硬化进展和辅助早期动脉粥样硬化患者管理提供新的影像工具。

研究设计与样本

  • 单中心横断面研究,连续纳入2022年8月至2023年5月无颈动脉斑块志愿者和低度颈动脉狭窄患者,根据8周内头部CT或MRI结果分为有症状组和无症状组,使用迈瑞Resona R9超声系统行向量血流成像。

关键影像表现/征象

  • 患者颈动脉分叉处壁面剪切应力和湍流指数高于志愿者。
  • 有症状患者斑块表面壁面剪切应力高于无症状患者。
  • 斑块下游侧因血流动力学更易发生斑块破裂。

临床应用与阅片要点

  • 作者认为颈动脉超声高帧率向量血流成像可能为监测动脉粥样硬化进展和辅助早期动脉粥样硬化患者管理提供新的影像工具。
  • 作者指出斑块下游侧因血流动力学更易破裂,可关注斑块下游表面的血流动力学参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To explore the role of quantitative evaluation using carotid ultrasonography (US)-based high-frame-rate vector flow (V Flow) imaging in patients with low carotid stenosis.

METHODS: This single-centre cross-sectional study consecutively recruited volunteers without carotid plaque and patients with low carotid stenosis from August 2022 to May 2023. Patients were divided into symptomatic and asymptomatic groups according to their head CT or MRI results within 8 weeks. All V Flow imaging examinations were performed using a Mindray Resona R9 US system. The wall shear stress (WSS) values, oscillatory shear index (OSI) values, and turbulence (Tur) indexes in the normal common carotid artery (CCA), normal carotid bifurcation (CB), and on the upstream and downstream surface of carotid plaque were measured. Pearson Chi-square test and Fisher exact test were used for counting data according to their type. For measurement data, independent sample t test and non-parametric rank sum test were used.

RESULTS: The results proved that patients have higher WSS values and Tur indexes of CB than volunteers, and higher WSS values were detected on the surface of the plaques in symptomatic patients. What's more, the downstream side of the plaque was more vulnerable to plaque rupture than the upstream side due to more dynamic blood flow.

CONCLUSION: Therefore, carotid US-based high-frame-rate V Flow imaging provides reliable mechanical biomarkers for assessing the haemodynamic change in patients with low stenosis. Our study may provide a new imaging tool for monitoring the progression of atherosclerosis and aiding the management of early atherosclerotic patients.

ADVANCES IN KNOWLEDGE: Our study firstly investigated the difference of V Flow parameters on the surface of carotid plaques between symptomatic and asymptomatic patients with low carotid stenosis, which is expected to provide haemodynamic information and the mechanical basis for plaque rupture.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen J, Zhang L, Gu S, et al. Quantitative evaluation using carotid ultrasonography-based high-frame-rate vector flow imaging in patients with low carotid stenosis. Br J Radiol. 2024. PMID: 38885374. doi:10.1093/bjr/tqae115

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。