彩色多普勒超声评估无名动脉、锁骨下动脉及颈总动脉狭窄
这项2013至2022年的回顾性多中心研究纳入636例同时接受颈动脉多普勒超声与数字减影血管造影的患者,其中无名动脉狭窄58例、颈总动脉狭窄147例、锁骨下动脉狭窄154例。研究通过受试者工作特征分析确定各动脉收缩期峰值流速预测≥50%和≥70%狭窄的阈值,并报告相应的敏感度和特异度。
要点
- 无名动脉收缩期峰值流速>206 cm/s预测≥50%狭窄,敏感度82.8%、特异度91.4%。
- 无名动脉收缩期峰值流速>285 cm/s预测≥70%狭窄,敏感度89.2%、特异度94.9%。
- 颈总动脉收缩期峰值流速>175 cm/s预测≥50%狭窄,敏感度78.2%、特异度91.9%。
核心结论
- 有症状患者若无名动脉流速≥206 cm/s、颈总动脉流速≥175 cm/s或锁骨下动脉流速≥200 cm/s,需考虑进一步验证及是否需要血运重建。
研究设计与样本
- 回顾性多中心研究,2013至2022年纳入636例同时接受颈动脉多普勒超声和数字减影血管造影的患者。
诊断标准与关键数值
- 无名动脉狭窄:收缩期峰值流速>206 cm/s预测≥50%狭窄,敏感度82.8%、特异度91.4%;>285 cm/s预测≥70%狭窄,敏感度89.2%、特异度94.9%。
- 颈总动脉狭窄:收缩期峰值流速>175 cm/s预测≥50%狭窄,敏感度78.2%、特异度91.9%;>255 cm/s预测≥70%狭窄,敏感度87.1%、特异度87.2%。
- 锁骨下动脉狭窄:收缩期峰值流速>200 cm/s预测≥50%狭窄,敏感度68.2%、特异度84.4%;>305 cm/s预测≥70%狭窄,敏感度57.9%、特异度91.4%。
临床应用与阅片要点
- 作者结论认为,有症状患者无名动脉流速≥206 cm/s、颈总动脉流速≥175 cm/s或锁骨下动脉流速≥200 cm/s时,需考虑进一步验证及是否需要血运重建。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to validate the efficiency of Doppler ultrasonography for predicting the innominate, subclavian, and common carotid artery stenosis.
METHODS: This retrospective multicenter study between 2013 and 2022 enrolled 636 patients who underwent carotid Doppler ultrasonography and subsequent digital subtraction angiography. And 58 innominate artery stenosis, 147 common carotid artery stenosis, and 154 subclavian artery stenosis were included. The peak systolic velocity at innominate, subclavian, and common carotid artery, and velocity ratios of innominate artery to common carotid artery, innominate artery to subclavian artery, and common carotid artery to internal carotid artery were measured or calculated. The threshold values were determined using receiver operating characteristic analysis.
RESULTS: The threshold values of innominate artery stenosis were peak systolic velocity >206 cm/s (sensitivity: 82.8%; specificity: 91.4%) to predict ≥50% stenosis and >285 cm/s (sensitivity: 89.2%; specificity: 94.9%) to predict ≥70% stenosis. The threshold values of common carotid artery stenosis were peak systolic velocity >175 cm/s (sensitivity: 78.2%; specificity: 91.9%) to predict ≥50% stenosis and >255 cm/s (sensitivity: 87.1%; specificity: 87.2%) to predict ≥70% stenosis. The threshold values of subclavian artery stenosis were peak systolic velocity >200 cm/s (sensitivity: 68.2%; specificity: 84.4%) to predict ≥50% stenosis and >305 cm/s (sensitivity: 57.9%; specificity: 91.4%) to predict ≥70% stenosis.
CONCLUSIONS: Symptomatic patients with ultrasonic parameters of velocity at innominate artery ≥206 cm/s, velocity at common carotid artery ≥175 cm/s, or velocity at subclavian artery ≥200 cm/s need to be considered for further verification and whether revascularization is necessary.
引用
- Zhang J, Wu D, Wang S, et al. Color Duplex Ultrasonography for the Evaluation of Innominate, Subclavian, and Common Carotid Artery Stenosis. J Ultrasound Med. 2024. PMID: 38837497. doi:10.1002/jum.16492
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。