文献速递骨肌MR

深度学习重建的新一代0.55 T膝关节MRI:与传统3 T MRI的前瞻性比较

Deep Learning Reconstructed New-Generation 0.55 T MRI of the Knee-A Prospective Comparison With Conventional 3 T MRI.
PubMed 文献 · Invest Radiol · 2024-06-11

前瞻性纳入26例创伤后膝痛患者,同期完成52对深度学习重建(DLR)0.55 T与传统3 T膝关节MRI,由4名放射科医师独立评估图像质量、结构异常识别与分级及阅片信心。DLR 0.55 T图像质量良好(3.8分 vs 3 T的4.1分,P=0.06),结构异常识别一致性近乎完美(各读者κ≥0.80),DLR 0.55 T可可靠识别膝关节内部紊乱且阅片信心高。

要点

  • DLR 0.55 T与3 T膝关节MRI对结构异常识别的一致性近乎完美(各读者κ≥0.80)。
  • DLR 0.55 T图像质量良好(3.8分),与3 T(4.1分)差异未达统计学显著(P=0.06)。
  • 3名读者对3 T报告软骨病变的信心高于DLR 0.55 T。

核心结论

  • 新一代0.55 T DLR膝关节MRI图像质量良好、与常规3 T MRI相当,可可靠识别膝关节内部紊乱且阅片信心高。

研究设计与样本

  • 前瞻性研究纳入26例创伤后膝痛患者(5例女性),在同一检查时段获取52对DLR 0.55 T与常规3 T膝关节MRI,0.55 T图像采用新型商用DLR算法重建,由4名委员会认证放射科医师独立阅片。

关键影像表现/征象

  • DLR 0.55 T与3 T MRI对骨、软骨、半月板、韧带及肌腱病变的存在与否及分级进行对照评估。
  • 读者共识评价DLR 0.55 T与3 T图像质量良好,分别为3.8分与4.1分(满分5分),P=0.06。
  • 所有读者对结构异常识别的一致性近乎完美(各κ≥0.80)。
  • 软骨病变分级的一致性为中等至近乎完美(κ=0.65-0.86),半月板病变分级为中等至近乎完美(κ=0.71-1.0)。

诊断标准与关键数值

  • 以传统3 T MRI为对照,DLR 0.55 T对结构异常识别的一致性各读者κ≥0.80。
  • 软骨病变分级一致性κ=0.65-0.86,半月板病变分级一致性κ=0.71-1.0。
  • 图像质量采用5分制评分,DLR 0.55 T为3.8分,3 T为4.1分,P=0.06。

临床应用与阅片要点

  • DLR 0.55 T膝关节MRI可用于创伤后膝痛患者骨、软骨、半月板、韧带及肌腱病变的识别与分级。
  • 3名读者对3 T报告软骨病变的信心高于DLR 0.55 T,阅片时对软骨病变可结合3 T或必要时补充序列。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to compare deep learning reconstructed (DLR) 0.55 T magnetic resonance imaging (MRI) quality, identification, and grading of structural anomalies and reader confidence levels with conventional 3 T knee MRI in patients with knee pain following trauma.

MATERIALS AND METHODS: This prospective study of 26 symptomatic patients (5 women) includes 52 paired DLR 0.55 T and conventional 3 T MRI examinations obtained in 1 setting. A novel, commercially available DLR algorithm was employed for 0.55 T image reconstruction. Four board-certified radiologists reviewed all images independently and graded image quality, noted structural anomalies and their respective reporting confidence levels for the presence or absence, as well as grading of bone, cartilage, meniscus, ligament, and tendon lesions. Image quality and reader confidence levels were compared ( P < 0.05, significant), and MRI findings were correlated between 0.55 T and 3 T MRI using Cohen kappa (κ).

RESULTS: In reader's consensus, good image quality was found for DLR 0.55 T MRI and 3 T MRI (3.8 vs 4.1/5 points, P = 0.06). There was near-perfect agreement between 0.55 T DLR and 3 T MRI regarding the identification of structural anomalies for all readers (each κ ≥ 0.80). Substantial to near-perfection agreement between 0.55 T and 3 T MRI was reported for grading of cartilage (κ = 0.65-0.86) and meniscus lesions (κ = 0.71-1.0). High confidence levels were found for all readers for DLR 0.55 T and 3 T MRI, with 3 readers showing higher confidence levels for reporting cartilage lesions on 3 T MRI.

CONCLUSIONS: In conclusion, new-generation 0.55 T DLR MRI provides good image quality, comparable to conventional 3 T MRI, and allows for reliable identification of internal derangement of the knee with high reader confidence.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Donners R, Vosshenrich J, Segeroth M, et al. Deep Learning Reconstructed New-Generation 0.55 T MRI of the Knee-A Prospective Comparison With Conventional 3 T MRI. Invest Radiol. 2024. PMID: 38857414. doi:10.1097/RLI.0000000000001093

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。