采用多交织X制备TSE与直观弛豫测量(MIXTURE)的3D高分辨率各向同性膝关节MRI同步形态学与T2映射的临床评估
研究纳入20例膝关节疼痛患者,比较3D MIXTURE(单次扫描同步获得形态学与T2映射)与常规2D TSE的图像质量和病灶显示。结果显示两者整体诊断信心和对比噪声比相当,MIXTURE测得软骨T2值范围为26.1至50.7 ms,病灶区与正常区差异有统计学意义(p < 0.05)。
要点
- MIXTURE可在单次扫描中同步获得形态学图像与定量T2映射。
- MIXTURE与2D TSE的整体诊断信心和对比噪声比相当。
- 软骨T2值病灶区与正常区差异有统计学意义(p < 0.05)。
核心结论
- MIXTURE有助于提供用于解剖和病理评估的高分辨率信息。
研究设计与样本
- 体模研究加在体人类扫描,纳入20例膝关节疼痛患者,由两名经验丰富的放射科医生视觉评估图像质量和病灶显示,比较MIXTURE与常规2D TSE。
关键影像表现/征象
- MIXTURE基于3D TSE,以交织方式包含和不包含T2准备模块,单次扫描同时获得PDW和脂肪抑制T2W形态学图像及定量T2映射。
- MIXTURE与2D TSE的整体诊断信心和对比噪声比被认为相当。
- 在体膝关节软骨测得的T2值范围为26.1至50.7 ms。
诊断标准与关键数值
- MIXTURE所选T2准备模块与当前标准相比产生一致的T2值。
- 软骨T2值在病灶区与正常区之间差异有统计学意义(p < 0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Quantitative MRI techniques such as T2 mapping are useful in comprehensive evaluation of various pathologies of the knee joint yet require separate scans to conventional morphological measurements and long acquisition times. The recently introduced 3D MIXTURE (Multi-Interleaved X-prepared Turbo-Spin Echo with Intuitive Relaxometry) technique can obtain simultaneous morphologic and quantitative information of the knee joint. To compare MIXTURE with conventional methods and to identify differences in morphological and quantitative information.
METHODS: Phantom studies were conducted, and in vivo human scans were performed (20 patients) presented with knee arthralgia. MIXTURE is based on 3D TSE without and with T2 preparation modules in an interleaved manner for both morphology with PDW and fat suppressed T2W imaging as well as quantitative T2 mapping within one single scan. Image quality and lesion depiction were visually assessed and compared between MIXTURE and conventional 2D TSE by two experienced radiologists. Contrast-to-noise ratio was used to assess the adjacent tissue contrast in a quantitative way for both obtained PDW and fat suppressed T2W images. Quantitative T2 values were measured in phantom and from in vivo knee cartilage.
RESULTS: The overall diagnostic confidence and contrast-to-noise ratio were deemed comparable between MIXTURE and 2D TSE. While the chosen T2 preparation modules for MIXTURE rendered consistent T2 values comparing to the current standard, measured cartilage T2 values ranged from 26.1 to 50.7 ms, with significant difference between the lesion and normal areas (p < 0.05).
CONCLUSIONS: MIXTURE can help to provide high-resolution information for both anatomical and pathological assessment.
引用
- Sakai T, Yoneyama M, Zhang S, et al. Clinical evaluation of 3D high-resolution isotropic knee MRI using Multi-Interleaved X-prepared TSE with inTUitive RElaxometry (MIXTURE) for simultaneous morphology and T2 mapping. Eur J Radiol. 2024. PMID: 38897053. doi:10.1016/j.ejrad.2024.111579