能否利用肩部CT扫描和人工智能机会性筛查低骨密度
本研究纳入194例50岁及以上患者,评估肩部CT上骨骼CT衰减值预测低骨密度(骨量减少/骨质疏松)的能力,并比较支持向量机(SVM)与k近邻(kNN)两种机器学习模型的预测性能。结果显示锁骨CT衰减值195.4 HU预测低骨密度的敏感度0.577、特异度0.781、AUC 0.701;测试集中SVM敏感度0.686、特异度1.00、AUC 0.857,kNN敏感度0.966、特异度0.200、AUC 0.583。SVM优于锁骨CT衰减值(P = .003),但不优于kNN模型(P = .098)。结论认为锁骨CT衰减值预测低骨密度最佳,但多变量SVM预测低骨密度更优。
要点
- 锁骨CT衰减值195.4 HU预测低骨密度:敏感度0.577、特异度0.781、AUC 0.701。
- 测试集中SVM预测低骨密度AUC 0.857,优于锁骨CT衰减值(P = .003)。
- SVM与kNN模型AUC比较无统计学显著差异(P = .098)。
核心结论
- 锁骨CT衰减值预测低骨密度最佳,但多变量SVM预测低骨密度更优。
- SVM利用多部位CT衰减值预测低骨密度最佳。
研究设计与样本
- 本研究为研究论文,纳入194例年龄50岁及以上患者(69.2 ± 9.1岁;170例女性)。
- 患者于2010年1月1日至2021年12月31日期间接受非增强肩部CT扫描,并与双能X线吸收测定法检查间隔在1年以内。
- 使用3D-Slicer获取肱骨、肩胛盂、喙突、肩峰、锁骨、第1、第2和第3肋的CT衰减值。
- 采用支持向量机(SVM)和k近邻(kNN)预测低骨密度,并用DeLong检验比较曲线下面积(AUC)。
诊断标准与关键数值
- 锁骨CT衰减值195.4 HU预测低骨密度:敏感度0.577、特异度0.781、AUC 0.701。
- 测试集中SVM预测低骨密度:敏感度0.686、特异度1.00、AUC 0.857。
- 测试集中kNN模型预测低骨密度:敏感度0.966、特异度0.200、AUC 0.583。
- SVM预测低骨密度优于锁骨CT衰减值(P = .003),但不优于kNN模型(P = .098)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate whether the CT attenuation of bones seen on shoulder CT scans could be used to predict low bone mineral density (BMD) (osteopenia/osteoporosis), and to compare the performance of two machine learning models to predict low BMD.
METHODS: In this study, we evaluated 194 patients aged 50 years or greater (69.2 ± 9.1 years; 170 females) who underwent unenhanced shoulder CT scans and dual-energy X-ray absorptiometry within 1 year of each other between January 1, 2010, and December 31, 2021. The CT attenuation of the humerus, glenoid, coracoid, acromion, clavicle, first, second, and third ribs was obtained using 3D-Slicer. Support vector machines (SVMs) and k-nearest neighbours (kNN) were used to predict low BMD. DeLong test was used to compare the areas under the curve (AUCs).
RESULTS: A CT attenuation of 195.4 Hounsfield Units of the clavicle had a sensitivity of 0.577, specificity of 0.781, and AUC of 0.701 to predict low BMD. In the test dataset, the SVM had sensitivity of 0.686, specificity of 1.00, and AUC of 0.857, while the kNN model had sensitivity of 0.966, specificity of 0.200, and AUC of 0.583. The SVM was superior to the CT attenuation of the clavicle (P = .003) but not better than the kNN model (P = .098).
CONCLUSION: The CT attenuation of the clavicle was best for predicting low BMD; however, a multivariable SVM was superior for predicting low BMD.
ADVANCES IN KNOWLEDGE: SVM utilizing the CT attenuations at many sites was best for predicting low BMD.
引用
- Sebro R, De la Garza-Ramos C. Can we screen opportunistically for low bone mineral density using CT scans of the shoulder and artificial intelligence? Br J Radiol. 2024. PMID: 38837337. doi:10.1093/bjr/tqae109
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。