文献速递骨肌CT

骨报告和数据系统(Bone-RADS)在计算机断层扫描上的诊断性能与阅片者间信度

Diagnostic performance and inter-reader reliability of bone reporting and data system (Bone-RADS) on computed tomography.
PubMed 文献 · Skeletal Radiol · 2024-06-09

该回顾性分析纳入179例于2005年3月至2021年9月间接受骨活检的患者,由两名放射科医生用Bone-RADS对CT上的孤立性骨病变分类,以组织病理学为标准参考。结果显示Bone-RADS对溶骨性病变恶性判断敏感度高(读者1为95%、读者2为82%),但对溶骨性和硬化/混合性病变的特异度和准确度均低,阅片者间信度为中等至很好(总体κ=0.744)。

要点

  • Bone-RADS对溶骨性病变恶性判断敏感度高(读者1 95%、读者2 82%),但特异度仅11%。
  • Bone-RADS对硬化/混合性病变敏感度75%和68%,特异度均27%,准确度45%和42%。
  • 阅片者间信度总体κ=0.744,溶骨性病变κ=0.565,硬化/混合性病变κ=0.851。

核心结论

  • Bone-RADS对溶骨性骨病变的恶性判断具有高敏感度及良好的阅片者间信度,但对溶骨性和硬化/混合性病变的特异度和准确度均差。

研究设计与样本

  • 回顾性分析纳入179例患者(平均年龄56±18岁,94例男性),均为2005年3月至2021年9月间接受骨活检、CT显示孤立性骨病变且有足够组织病理学结果者,由两名放射科医生按Bone-RADS(1为良性,4为恶性)分类,以组织病理学为标准参考。

关键影像表现/征象

  • 骨病变分为两组:溶骨性103例(病理:良性34例、中间性12例、恶性54例、骨髓炎3例)和硬化/混合性76例(病理:良性46例、中间性2例、恶性26例、骨髓炎2例)。

诊断标准与关键数值

  • 溶骨性病变:读者1敏感度95%、特异度11%、准确度57%;读者2敏感度82%、特异度11%、准确度50%。
  • 硬化/混合性病变:读者1敏感度75%、特异度27%、准确度45%;读者2敏感度68%、特异度27%、准确度42%。
  • 阅片者间信度:总体κ=0.744,溶骨性病变κ=0.565,硬化/混合性病变κ=0.851。

局限性

  • 原文指出Bone-RADS特异度和准确度差的一个可能解释是所提算法严重依赖疼痛和恶性肿瘤病史等临床特征。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic performance and inter-reader reliability of the Bone Reporting and Data System (Bone-RADS) for solitary bone lesions on CT.

MATERIALS AND METHODS: This retrospective analysis included 179 patients (mean age, 56 ± 18 years; 94 men) who underwent bone biopsies between March 2005 and September 2021. Patients with solitary bone lesions on CT and sufficient histopathology results were included. Two radiologists categorized the bone lesions using the Bone-RADS (1, benign; 4, malignant). The diagnostic performance of the Bone-RADS was calculated using histopathology results as a standard reference. Inter-reader reliability was calculated.

RESULTS: Bone lesions were categorized into two groups: 103 lucent (pathology: 34 benign, 12 intermediate, 54 malignant, and 3 osteomyelitis) and 76 sclerotic/mixed (pathology: 46 benign, 2 intermediate, 26 malignant, and 2 osteomyelitis) lesions. The Bone-RADS for lucent lesions had sensitivities of 95% and 82%, specificities of 11% and 11%, and accuracies of 57% and 50% for readers 1 and 2, respectively. The Bone-RADS for sclerotic/mixed lesions had sensitivities of 75% and 68%, specificities of 27% and 27%, and accuracies of 45% and 42% for readers 1 and 2, respectively. Inter-reader reliability was moderate to very good (κ = 0.744, overall; 0.565, lucent lesions; and 0.851, sclerotic/mixed lesions).

CONCLUSION: Bone-RADS has a high sensitivity for evaluating malignancy in lucent bone lesions and good inter-reader reliability. However, it has poor specificity and accuracy for both lucent and sclerotic/mixed lesions. A possible explanation is that proposed algorithms heavily depend on clinical features such as pain and history of malignancy.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Park C, Azhideh A, Pooyan A, et al. Diagnostic performance and inter-reader reliability of bone reporting and data system (Bone-RADS) on computed tomography. Skeletal Radiol. 2024. PMID: 38853160. doi:10.1007/s00256-024-04721-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。