双源双能CT与深度学习用于甲状腺癌CT图像上可疑淋巴结的分类
这项前瞻性研究纳入183例甲状腺癌患者的281枚常规CT上阴性或可疑的淋巴结,比较双能CT定量参数模型与六种深度学习模型的诊断性能;基于小视野CT图像的VGG16模型准确率和敏感度分别为86%和88%(AUC 0.89),优于双能CT参数模型(准确率74.4%、敏感度84.2%、AUC 0.857)。
要点
- 常规CT上阴性或可疑的甲状腺癌淋巴结,VGG16模型鉴别良恶性准确率86%、敏感度88%、AUC 0.89。
- 双能CT参数最佳组合模型诊断准确率74.4%、敏感度84.2%、AUC 0.857。
- 281枚目标淋巴结中65.5%短径小于4 mm,深度学习模型在此类小淋巴结上表现更优。
核心结论
- 基于小视野CT图像的VGG16模型诊断准确率和敏感度优于双能CT光谱参数回归模型,可作为无创影像生物标志物预测甲状腺癌患者常规CT无可疑特征的恶性淋巴结。
研究设计与样本
- 前瞻性研究,2020年10月至2021年3月纳入375例甲状腺疾病患者行小视野薄层双能甲状腺CT并接受甲状腺手术,最终分析183例患者的281枚淋巴结;以病理报告为参考标准,比较六种深度学习模型与双能CT参数模型的分类性能。
诊断标准与关键数值
- 双能CT参数最佳组合模型AUC 0.857,诊断准确率74.4%,敏感度84.2%(p < 0.001);VGG16模型准确率86%、敏感度88%、AUC 0.89;目标淋巴结为小视野CT图像上阴性或可疑者,其中65.5%短径小于4 mm。
临床应用与阅片要点
- 作者提出基于深度学习的模型可用于预测常规CT图像上无可疑特征的甲状腺癌恶性淋巴结,其诊断准确率和敏感度优于基于光谱参数的回归模型。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study investigated the diagnostic performance of dual-energy computed tomography (CT) and deep learning for the preoperative classification of equivocal lymph nodes (LNs) on CT images in thyroid cancer patients.
METHODS: In this prospective study, from October 2020 to March 2021, 375 patients with thyroid disease underwent thin-section dual-energy thyroid CT at a small field of view (FOV) and thyroid surgery. The data of 183 patients with 281 LNs were analyzed. The targeted LNs were negative or equivocal on small FOV CT images. Six deep-learning models were used to classify the LNs on conventional CT images. The performance of all models was compared with pathology reports.
RESULTS: Of the 281 LNs, 65.5% had a short diameter of less than 4 mm. Multiple quantitative dual-energy CT parameters significantly differed between benign and malignant LNs. Multivariable logistic regression analyses showed that the best combination of parameters had an area under the curve (AUC) of 0.857, with excellent consistency and discrimination, and its diagnostic accuracy and sensitivity were 74.4% and 84.2%, respectively (p < 0.001). The visual geometry group 16 (VGG16) based model achieved the best accuracy (86%) and sensitivity (88%) in differentiating between benign and malignant LNs, with an AUC of 0.89.
CONCLUSIONS: The VGG16 model based on small FOV CT images showed better diagnostic accuracy and sensitivity than the spectral parameter model. Our study presents a noninvasive and convenient imaging biomarker to predict malignant LNs without suspicious CT features in thyroid cancer patients.
CLINICAL RELEVANCE STATEMENT: Our study presents a deep-learning-based model to predict malignant lymph nodes in thyroid cancer without suspicious features on conventional CT images, which shows better diagnostic accuracy and sensitivity than the regression model based on spectral parameters.
KEY POINTS: Many cervical lymph nodes (LNs) do not express suspicious features on conventional computed tomography (CT). Dual-energy CT parameters can distinguish between benign and malignant LNs. Visual geometry group 16 model shows superior diagnostic accuracy and sensitivity for malignant LNs.
引用
- Li S, Wei X, Wang L, et al. Dual-source dual-energy CT and deep learning for equivocal lymph nodes on CT images for thyroid cancer. Eur Radiol. 2024. PMID: 38904758. doi:10.1007/s00330-024-10854-w