文献速递乳腺技术与安全US

一种用于识别乳腺和腋窝肿瘤标记物的新型彩色多普勒超声伪像:类开花伪像

A Novel Color Doppler Ultrasound Artifact for Identifying Breast and Axilla Tumor Markers: Blooming-like Artifact.
PubMed 文献 · Acad Radiol · 2024-06-27

这项前瞻性研究于2023年8月至12月纳入20例乳腺和腋窝放置标记物的患者,通过降低速度标尺和增高彩色增益在彩色多普勒超声上产生类开花伪像,结果显示该伪像可定位乳腺病灶和腋窝淋巴结中的金属标记物。作者认为类开花伪像是一种新颖且易于应用的方法,可在诊断检查中确定乳腺和腋窝金属标记物的位置。

要点

  • 降低速度标尺至4.6-6.1 cm/s并增高彩色增益至58-80可产生类开花伪像。
  • 该伪像可定位乳腺病灶和腋窝淋巴结中放置的活检标记物。
  • 研究纳入20例患者,其中新辅助化疗前14例、化疗后6例。

核心结论

  • 类开花彩色多普勒超声伪像是一种新颖且易于应用的方法,可在诊断检查中确定乳腺和腋窝金属标记物的位置。

研究设计与样本

  • 前瞻性研究,于2023年8月至12月连续纳入乳腺和腋窝放置标记物的患者,包括新辅助化疗前和化疗后患者。
  • 共纳入20例患者,平均年龄55.50岁±12.04 SD(范围31-72岁),其中新辅助化疗前14例(70%)、化疗后6例(30%)。
  • 共标记20个乳腺病灶和6个腋窝淋巴结,其中新辅助化疗前14个乳腺病灶和5个腋窝淋巴结、化疗后6个乳腺病灶和1个腋窝淋巴结。
  • 检查使用14-5 MHz线阵探头,具备B模式和多普勒功能;彩色多普勒超声发射频率设为14-5 MHz,彩色频率6-7,彩色增益58-80,速度标尺4.6-6.1 cm/s。

关键影像表现/征象

  • 通过降低速度标尺和增高彩色增益,可产生类开花伪像。
  • 放置活检标记物的乳腺病灶和腋窝淋巴结均可用类开花伪像定位。
  • 乳腺病灶平均大小20.95 mm±6.56 SD(范围15-40 mm)。
  • 腋窝淋巴结平均大小20.63 mm±5.01 SD(范围原文写作31-14)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

UNLABELLED: RATIONALE AND OBJECTIVES: Detection of tumor marker location in the breast and axilla using a less commonly utilized color Doppler ultrasound (CDUS) artifact.

MATERIALS AND METHODS: This prospective study was conducted between August and December 2023 and included consecutive patients with markers placed in the breast and axilla, both before and after neoadjuvant chemotherapy (NACT). Examinations were conducted using a 14 to 5 MHz linear array transducer with B-mode and Doppler capability. By reducing the velocity scale and increasing the color gain values, adjustments were made to create a bloom-like artifact. CDUS was performed with the ultrasound transmit frequency set between 14-5 MHz, color frequency between 6 and 7, color gain ranging from 58 to 80, and velocity scale within the range of 4.6-6.1 cm/s.

RESULTS: Twenty patients, with a mean age of 55.50 years ± 12.04 SD (range, 31-72), were included in the study. 14 (70%) were pre-NACT, and six (30%) were post-NACT patients. A total of 20 breast lesions and six axillary lymph nodes were marked. The breast lesions and axillary lymph nodes where the biopsy marker was placed (14 breast lesions and five axillary lymph nodes before NACT, six breast lesions and one axillary lymph node after NACT) were localized with blooming-like artifact. The average size of breast lesions was 20.95 mm ± 6.56 SD (range, 15-40). For axillary lymph nodes, the average size was 20.63 mm ± 5.01 SD (range: 31-14).

CONCLUSION: The blooming-like CDUS artifact is a novel and easily applicable method determining the location of metallic markers in the breast and axilla on diagnostic examinations.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Asik M, Erdem G, Gezgin M, et al. A Novel Color Doppler Ultrasound Artifact for Identifying Breast and Axilla Tumor Markers: Blooming-like Artifact. Acad Radiol. 2024. PMID: 38942644. doi:10.1016/j.acra.2024.05.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。